Research on the seismic performance of steel structures has led to the development of improved structures, which minimize structural and non-structural damage and can be reused immediately after an earthquake. Moreover, significant advances have been made for predicting the response of steel members, connections, and structural systems exposed to fire. Nevertheless, the research on the reuse of steel structures after a fire event is limited. A steel structure designed according to the current seismic codes can survive a fire without significant structural damage and may be repaired and reused. Therefore, it is of great importance to study whether the reuse of steel structures after a fire is safe in high seismicity areas. This paper investigates the seismic performance of steel columns that are pre-damaged due to fire. For this purpose, sophisticated finite element models have been developed and validated against experimental data. It was concluded that the models accurately predict the behaviour of beams-columns at elevated temperatures. First, the behaviour of the columns was studied using simplified boundary conditions; the surrounding structure was not included in the numerical model. Thermal-structural analyses were performed to determine the structural damage induced by the fire. Subsequently, the cyclic performance of the columns was investigated, considering both the residual post-fire deformations and the proper material properties. Aiming to obtain more realistic results, the complicated interaction between the heated columns and the surrounding structure was considered in the modelling. For this reason, the fire behaviour of a seismic resistant frame was simulated. Then, the behaviour of fire-damaged columns under cyclic loading was assessed. The analysis of the results demonstrates the effect of the post-fire damage on the cyclic behaviour of columns.
Purpose The primary purpose of this paper is the development of a fire–structure interface (FSI) model, which is referred in this study as a simplified “dual-layer” model. It is oriented for design purposes, in the cases where fire-compartments exceed the “regular” dimensions, as they are defined by the guidelines of the codes (EN 1991-1-2). Design/methodology/approach The model can be used at the post-processing stage of computational fluid dynamics (CFD) analysis and it is based on the gas-temperature field (spatial and temporal) of the fire-compartment. To use the “dual-layer” model, first the gas-temperature (discrete) function along the height of the fire-compartment, at discrete plan–view points should be determined through the output of the CFD analysis. The model “compresses” the point data to (spatial) virtual zones, which are divided into two layers (with respect to the height of the fire-compartment) of uniform temperature: the upper (hot) layer and the lower (cold) layer. Findings The model calculates the temporal evolution of the gas-temperature in the fire compartment in every virtual zone which is divided in two layers (hot and cold layer). Originality/value The main advantage of this methodology is that actually only three different variables (height of interface upper-layer temperature and lower-layer temperature) are exported during the post-processing stage of the CFD analysis, for every virtual zone. Next, the gas-temperature can be used for the determination of the temperature profile of structural members using simple models that are proposed in EN 1993-1-2.