Interventional radiology and cardiology are rapidly growing areas of minimally invasive surgery, covering multiple diagnostic and interventional procedures. Treatment via endovascular techniques has become the go-to approach, thanks to its minimally invasive nature and its effectiveness in reducing hospitalisation and total time to recovery when compared to open surgery. Although x-ray fluoroscopy is currently the gold standard imaging technique for endovascular interventions, it presents occupational safety hazards to medical personnel and potential risks to patients, especially paediatric patients, because of its inherent ionising radiation. Magnetic resonance imaging (MRI), with its unique ability to provide radiation-free imaging, and acquiring morphologic and functional information, holds great promise in the advancement of image-guided navigation through the vasculature. Moreover, MRI has the potential to combine diagnosis, therapy and early evaluation of therapy in the same intervention. However, MR-guided interventions face a major challenge due to the presence of a large magnetic field (1.5/3 Tesla), which limits the set of materials suitable for the construction of key instrumentation (sheaths, catheters and guidewires). Despite these challenges, in recent years, significant progress has been made in the development of interventional devices, which comprise biocompatible, MR safe and MR visible materials. In an attempt to encourage and accelerate the development of MR-guided endovascular instrumentation, we present a systematic and illustrated overview of the plethora of work targeting to overcome the aforementioned limitations which are underpinned by the interdependent advancements in science, technology, engineering, mathematics and medicine (STEMM).
14 January 2021 in CardioVascular and Interventional Radiology
Purpose: Endovascular robotics is an emerging technology within the developing field of medical robotics. This was a prospective evaluation to assess safety and feasibility of robotic-assisted carotid artery stenting. Materials and Methods: Consecutive cases of carotid artery stenting cases performed over period of 24 months, from May 2015 to October 2016, using the Magellan Robotic System (Hansen, Mountain View, CA) were included. All cases utilised the robotic system to navigate the arch, obtain a stable position in the common carotid artery, followed by manual manipulation of Embolic Protection Devices and self-expandable stents through the robotic catheter. Patients demographics, clinical indications, anatomical features, technical and clinical success, complication rate and hospital stay were prospectively recorded. Results: Thirteen patients, 10 males (78.5%), with an average age of 68.7 years were treated. Mean follow up time was 30 months. Ten patients (91%) were symptomatic at presentation. Anatomical indications for endovascular stent insertion were previous open surgery to the neck ± radiotherapy (87.5%) and hostile anatomy for open surgery (12.5%). Technical success was 100% and the robotic system demonstrates enhanced stability during arch and lesion crossing. There were no neurological complications post-operatively. Average hospital stay was 3 days (range 2–6 days) and a change in serum creatinine of −7.8 μmol/L. There was no documented case of in stent restenosis, new or worsening neurology during follow-up. Conclusion: These results illustrate safety and feasibility of robotic endovascular revascularisation for carotid disease and demonstrates potential to enhance peri-procedural safety through improved control and stability.
28 June 2023 in CardioVascular and Interventional Radiology
Purpose: To assess the prevalence of burnout amongst Interventional Radiologists (IRs) in the United Kingdom and identify demographic and practice-related stressors that may adversely affect well-being. Materials and Methods: A survey of 36 questions was divided into two sections. Section A consisted of 14 questions that assessed demographics and work characteristics; Section B assessed burnout, utilizing the 22-item Maslach burnout inventory. Four additional open-ended questions were included to allow participants to voice opinions on the biggest contributors to workplace burnout and plans that could be implemented to alleviate this. The questionnaire was distributed to the British Society of interventional (BSIR) members. The study was conducted between August and September 2022. Results: Moderate to severe scores in emotional exhaustion (EE) were recorded in 65% of participants (moderate 26%; severe 39%) of participants r. Moderate to severe depersonalization (DP) scores were recorded in 46% of participants (moderate 23%; severe 23%). Low-moderate levels of personal accomplishment (PA) scores were recorded in 77% of respondents (low 50%; moderate 27%). Weekly hours and out-of-hour IR cover were statistically significant in predicting emotional exhaustion. Age, sex (male), time available for teaching, and weekly hours were statistically significant in predicting the depersonalisation score. Age was a predictive factor for personal accomplishment. The most recurring themes in open response to major contributors of burnout were shortage of IR clinicians and supporting staff as well as the increasing IR workload. Conclusions: This survey has demonstrated high prevalence of burnout amongst Interventional Radiologists in UK. Urgent measures are required to tackle the workforce shortage, recognition of IR workload and control IR resources.