Mohamed E. M. K. Abdelaziz

Mohamed E. M. K. Abdelaziz

Auto-generated profile, based on publicly available information

Mohamed E. M. K. Abdelaziz

Department of Metabolism Digestion and Reproduction Division of Systems Medicine Imperial College London London UK

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2024 in Science Advances
Verified
Journal Article
Open access
MAMohamed E. M. K. Abdelaziz
Mohamed E. M. K. Abdelaziz
JZJinshi Zhao
Jinshi Zhao
BRBruno Gil Rosa
Bruno Gil Rosa
HLHyun-Taek Lee
Hyun-Taek Lee
DSDaniel Simon
Daniel Simon
Burak TemelkuranBurak Temelkuran
Burak Temelkuran
Precise manipulation of flexible surgical tools is crucial in minimally invasive surgical procedures, necessitating a miniature and flexible robotic probe that can precisely direct the surgical instruments. In this work, we developed a polymer-based robotic fiber with a thermal actuation mechanism by local heating along the sides of a single fiber. The fiber robot was fabricated by highly scalable fiber drawing technology using common low-cost materials. This low-profile (below 2 millimeters in diameter) robotic fiber exhibits remarkable motion precision (below 50 micrometers) and repeatability. We developed control algorithms coupling the robot with endoscopic instruments, demonstrating high-resolution in situ molecular and morphological tissue mapping. We assess its practicality and safety during in vivo laparoscopic surgery on a porcine model. High-precision motion of the fiber robot delivered endoscopically facilitates the effective use of cellular-level intraoperative tissue identification and ablation technologies, potentially enabling precise removal of cancer in challenging surgical sites.

1 October 2018
Verified
Conference Paper
Closed access
GDG. Dagnino
G. Dagnino
JLJ. Liu
J. Liu
MAM. E. M. K. Abdelaziz
M. E. M. K. Abdelaziz
WCW. Chi
W. Chi
CRC. Riga
C. Riga
GYG.-Z. Yang
G.-Z. Yang
Robotic and computer assistance can bring significant benefits to endovascular procedures in terms of precision and stability, reduced radiation doses, improved comfort and access to difficult and tortuous anatomy. However, the design of current commercially available platforms tends to alter the natural bedside manipulation skills of the operator, so that the manually acquired experience and dexterity are not well utilized. Furthermore, most of these systems lack of haptic feedback, preventing their acceptance and limiting the clinical usability. In this paper a new robotic platform for endovascular catheterization, the CathBot, is presented. It is an ergonomic master-slave system with navigation system and integrated vision-based haptic feedback, designed to maintain the natural bedside skills of the vascular surgeon. Unlike previous work reported in literature, dynamic motion tracking of both the vessel walls the catheter tip is incorporated to create dynamic active constraints. The system was evaluated through a combined quantitative and qualitative user study simulating catheterization tasks on a phantom. Forces exerted on the phantom were measured. The results showed a 70% decrease in mean force and 61% decrease in maximum force when force feedback is provided. This research provides the first integration of vision-based dynamic active constraints within an ergonomic robotic catheter manipulator. The technological advances presented here, demonstrates that vision-based haptic feedback can improve the effectiveness, precision, and safety of robot-assisted endovascular procedures.

1 July 2021 in Progress in Biomedical Engineering
Verified
Journal Article
Open access
MAMohamed E M K Abdelaziz
Mohamed E M K Abdelaziz
LTLibaihe Tian
Libaihe Tian
MHMO HAMADY
MO HAMADY
GYGuang-Zhong Yang
Guang-Zhong Yang
Burak TemelkuranBurak Temelkuran
Burak Temelkuran
Interventional radiology and cardiology are rapidly growing areas of minimally invasive surgery, covering multiple diagnostic and interventional procedures. Treatment via endovascular techniques has become the go-to approach, thanks to its minimally invasive nature and its effectiveness in reducing hospitalisation and total time to recovery when compared to open surgery. Although x-ray fluoroscopy is currently the gold standard imaging technique for endovascular interventions, it presents occupational safety hazards to medical personnel and potential risks to patients, especially paediatric patients, because of its inherent ionising radiation. Magnetic resonance imaging (MRI), with its unique ability to provide radiation-free imaging, and acquiring morphologic and functional information, holds great promise in the advancement of image-guided navigation through the vasculature. Moreover, MRI has the potential to combine diagnosis, therapy and early evaluation of therapy in the same intervention. However, MR-guided interventions face a major challenge due to the presence of a large magnetic field (1.5/3 Tesla), which limits the set of materials suitable for the construction of key instrumentation (sheaths, catheters and guidewires). Despite these challenges, in recent years, significant progress has been made in the development of interventional devices, which comprise biocompatible, MR safe and MR visible materials. In an attempt to encourage and accelerate the development of MR-guided endovascular instrumentation, we present a systematic and illustrated overview of the plethora of work targeting to overcome the aforementioned limitations which are underpinned by the interdependent advancements in science, technology, engineering, mathematics and medicine (STEMM).

1 October 2018
Verified
Conference Paper
Closed access
WCWenqiang Chi
Wenqiang Chi
JLJindong Liu
Jindong Liu
MAMohamed E. M. K. Abdelaziz
Mohamed E. M. K. Abdelaziz
GDGiulio Dagnino
Giulio Dagnino
CRCelia Riga
Celia Riga
GYGuang-Zhong Yang
Guang-Zhong Yang
Emerging robot-assisted endovascular intervention has the potential to reduce X-ray radiations to the operator while enhancing the stability and dexterity of catheter manipulation. Supervised and shared autonomy of endovascular procedures could add further improvements in reduced fatigue and cognitive workloads of the operator, higher success rates of cannulation and improved surgical outcomes. However, robotic path planning for endovascular procedure is challenging due to complex and non-linear flow dynamics inside the vasculature. This paper presents a learning-based robotic catheterization platform addressing those challenges, this approach incorporates path integral reinforcement learning (RL) framework based on dynamic movement primitives (DMP) to enhance catheterization tasks by a customized robotic manipulator. The robotic trajectories were optimized through RL in order to avoid unwanted contacts between the catheter tip and the vessel wall. The proposed methods can adapt to different flow simulations, vascular models, and catheterization tasks. The quality of the catheterization was evaluated with performance metrics. The results show significant refinement of catheter paths by the proposed approach, resulting in shorter overall lengths and fewer contact forces, which can potentially reduce risks in endothelial wall damages, embolization, and stroke. The results support the development of robotic path planning for endovascular procedures as well as designing intelligent, hands-on robotic navigation platforms.

5 July 2024 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
TJTudor Jianu
Tudor Jianu
BHBaoru Huang
Baoru Huang
MVMinh Nhat Vu
Minh Nhat Vu
MAMohamed E. M. K. Abdelaziz
Mohamed E. M. K. Abdelaziz
Sebastiano FicheraSebastiano Fichera
Sebastiano Fichera
ANAnh Nguyen
Anh Nguyen
Autonomous robots in endovascular operations have the potential to navigate circulatory systems safely and reliably while decreasing the susceptibility to human errors. However, there are numerous challenges involved with the process of training such robots, such as long training duration and safety issues arising from the interaction between the catheter and the aorta. Recently, endovascular simulators have been employed for medical training but generally do not conform to autonomous catheterization due to the lack of standardization and RL framework compliance. Furthermore, most current simulators are closed-source, which hinders the collaborative development of safe and reliable autonomous systems through shared learning and community-driven enhancements. In this work, we introduce CathSim, an open-source simulation environment that accelerates the development of machine learning algorithms for autonomous endovascular navigation. We first simulate the high-fidelity catheter and aorta with a state-of-the-art endovascular robot. We then provide the capability of real-time force sensing between the catheter and the aorta in simulation. Furthermore, we validate our simulator by conducting two different catheterization tasks using two popular reinforcement learning algorithms, namely SAC and PPO. The experimental results show that our open-source simulator can mimic the behavior of real-world endovascular robots and facilitate the development of different autonomous catheterization tasks. Our simulator is publicly available at https://github.com/airvlab/cathsim.

1 November 2019
Verified
Conference Paper
Closed access
MMM. B. Molinero
M. B. Molinero
GDGiulio Dagnino
Giulio Dagnino
JLJun Liu
Jun Liu
WCW. Chi
W. Chi
MAM. E. M. K. Abdelaziz
M. E. M. K. Abdelaziz
GYG.Z. Yang
G.Z. Yang
Vascular diseases are the most common precursors to ischemic heart disease and stroke, which are two of the leading causes of death worldwide. Endovascular intervention is a minimally invasive surgical approach to treat such diseases. Compared to open surgery, it has the advantages of faster recovery, reduced need for general anesthesia, reduced blood loss and significantly lower mortality. Endovascular procedures require high surgical skills to minimize contacts between the manipulated instruments (catheters and guidewires) and the vessel wall, which represent one of the major risks for the patient. Robotic assistance can potentially improve the precision and stability of instruments manipulation. One key limitation of current commercial robotic platforms is the lack of haptic feedback, preventing their acceptance and limiting the clinical usability. This paper proposes to bring the benefit of haptic feedback to robot-assisted endovascular intervention. Here we hypothesize that the introduction of 3D haptic guidance during robot-assisted endovascular procedure can further improve the surgical performance and safety while overcoming the limitations of currently available technology. The proposed 3D haptic guidance allows the surgeon to sense the vasculature while controlling a catheter through a robotic haptic manipulator. Validation of the system is performed through end-user experiments with vascular surgeons on a bespoke surgical simulator. The obtained results demonstrate that 3D haptic guidance has the potential of improving effectiveness, precision, and safety of endovascular intervention. Furthermore, vascular surgeons found the proposed technology safe and overall easy to use, indicating its potential on real surgical procedures.