Alexis Kyriacou

Alexis Kyriacou

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2017 in IEEE Transactions on Power Systems
Verified
Journal Article
Open access
AKAlexis Kyriacou
Alexis Kyriacou
PDPanayiotis Demetriou
Panayiotis Demetriou
CPChristos Panayiotou
Christos Panayiotou
EKElias Kyriakides
Elias Kyriakides
Intentional Controlled Islanding (ICI) has been proposed as a corrective measure of last resort to split the power system into several sustainable islands and prevent cascading outages. This paper proposes a novel ICI algorithm based on a linear programming (LP) formulation that directly determines an islanding solution with minimal power-flow disruption for any given number of islands, while ensuring that each island contains only coherent generators. In addition, the proposed algorithm enables operators to constrain any transmission line to be excluded from the solution, allows the control of the size of islands and ensures their connectivity. The basis of the proposed LP formulation is an exact mixed integer linear programming (MILP) formulation. A search space reduction procedure that generates additional constraints for reducing the search space of the MILP is also proposed. In most cases, these additional constraints are enough for the relaxed MILP formulation (LP formulation) to generate optimal solutions. Nonetheless, the proposed LP formulation is executed as a part of a recursive linearization procedure, which ensures that optimal solutions are always obtained. Multiple simulation results demonstrate the ability of the proposed LP ICI algorithm to meet the requirement of real-time controlled islanding in large-scale power systems.

25 January 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
CKChristina Kakoulli
Christina Kakoulli
AKAlexis Kyriacou
Alexis Kyriacou
Michalis MichaelidesMichalis Michaelides
Michalis Michaelides
People spend up to 90% of their time indoors where they continuously interact with the indoor environment. Indoor Environmental Quality (IEQ), and in particular thermal comfort, Indoor Air Quality (IAQ), and acoustic and visual comfort, have proven to be significant factors that influence the occupants’ health, comfort, productivity and general well-being. The ongoing COVID-19 pandemic has also highlighted the need for real-life experimental data acquired through field measurement studies to help us understand and potentially control the impact of IEQ on the occupants’ health. In this context, there was a significant increase over the past two decades of field measurement studies conducted all over the world that analyse the IEQ in various indoor environments. In this study, an overview of the most important factors that influence the IAQ, thermal comfort, and the risk of virus transmission is first presented, followed by a comprehensive review of selected field measurement studies from the last 20 years. The main objective is to provide a broad overview of the current status of field measurement studies, to identify key characteristics, common outcomes, correlations, insights, as well as gaps, and to serve as the starting point for conducting future field measurement studies.

2 May 2022 in Heliyon
Verified
Journal Article
Open access
CKCorina Konstantinou
Corina Konstantinou
ACAndria Constantinou
Andria Constantinou
EKEleni G. Kleovoulou
Eleni G. Kleovoulou
AKAlexis Kyriacou
Alexis Kyriacou
CKChristina Kakoulli
Christina Kakoulli
Konstantinos Christos MakrisKonstantinos Christos Makris
Konstantinos Christos Makris
Combined pollutant effects from indoor and outdoor sources on children's health, while being at school have not been holistically tackled. The aim of the School Temperature and Environmental Pollutants Study (STEPS) was to perform a school population representative assessment of indoor air quality (IAQ) in primary schools of densely and intermediate populated areas of Cyprus (n = 42). The study took place during May–July 2021 when a school-specific COVID-19 protocol was in place. Questionnaire-based characteristics of schools/classrooms were collected along with 24/48-h long IAQ monitoring of air temperature, relative humidity (RH), particulate matter (PM), carbon dioxide (CO2) and volatile organic compounds (VOCs), using low-cost sensors. Mixed effect models assessed the IAQ determinants during school hours. Indoor PM, temperature, RH and VOCs increased with progressing school periods in the day, while indoor CO2 decreased. Indoor RH and CO2 were negatively associated with % open windows, while indoor PM2.5 was positively associated. Most of school time (85%), indoor air temperature exceeded the recommended upper limit (27 °C), while a third of indoor PM2.5 (24-h) measurements exceeded 15 μg/m3. The interplay of clean indoor air with adequate ventilation and adaptation to heat stress in schools is important and its comprehensive characterization requires holistic methodological approaches and tools.

12 October 2017 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Open access
AKAlexis Kyriacou
Alexis Kyriacou
Michalis MichaelidesMichalis Michaelides
Michalis Michaelides
VRVasso Reppa
Vasso Reppa
STStelios Timotheou
Stelios Timotheou
CPChristos G. Panayiotou
Christos G. Panayiotou
MPMarios M. Polycarpou
Marios M. Polycarpou
The automatic preservation of the indoor air quality (IAQ) is an important task of the intelligent building design in order to ensure the health and safety of the occupants. The IAQ, however, is often compromised by various airborne contaminants that penetrate the indoor environment as a result of accidents or planned attacks. In this paper, we provide the detailed analysis, implementation, and evaluation of a distributed methodology for detecting and isolating multiple contaminant events in large-scale buildings. Specifically, we consider the building as a collection of interconnected subsystems, and we design a contaminant event monitoring software agent for each subsystem. Each monitoring agent aims to detect the contaminant and isolate the zone where the contaminant source is located, while it is allowed to exchange information with its neighboring agents. For configuring the subsystems, we implement both exact and heuristic partitioning solutions. A main contribution of this paper is the investigation of the impact of the partitioning solution on the performance of the distributed contaminant detection and isolation (CDI) scheme with respect to the detectability and isolability of the contaminant sources. The performance of the proposed distributed CDI methodology is demonstrated using the models of real building case studies created on CONTAM.

1 May 2019 in Building and Environment
Verified
Journal Article
Closed access
AKAlexis Kyriacou
Alexis Kyriacou
MMMichalis P. Michaelides
Michalis P. Michaelides
DEDemetrios G. Eliades
Demetrios G. Eliades
CPChristos G. Panayiotou
Christos G. Panayiotou
MPMarios M. Polycarpou
Marios M. Polycarpou

1 June 2015
Verified
Conference Paper
Closed access
PDPanayiotis Demetriou
Panayiotis Demetriou
LHLenos Hadjidemetriou
Lenos Hadjidemetriou
AKAlexis Kyriacou
Alexis Kyriacou
EKElias Kyriakides
Elias Kyriakides
CPChristos Panayiotou
Christos Panayiotou
This paper presents a two-step approach for defining coherent generators in disturbed power systems based on the similarity among their inter-area oscillations and swing curves. In the first step, an online visualization of the generator swing curves is performed by extracting time domain solutions of the swing equation using PMU measurements. In the second step, the similarity between each pair of the generator swing curves is examined based on an intraclass correlation analysis. The pairwise similarity coefficients obtained are served as edge's weights to a fully connected graph. The grouping of the coherent generators is completed through a graph minimization algorithm. The proposed methodology is applied to the 39-Bus New England System and coherent generators are obtained for different operating points to provide a more accurate and realistic grouping.