Shaurya Bhatt

Mr. Shaurya Bhatt

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 January 2023 in Expert Review of Medical Devices
Verified
Journal Article
Closed access
SBShaurya Bhatt
Shaurya Bhatt
DJDeepak Joshi
Deepak Joshi
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
AGAnoop Kant Godiyal
Anoop Kant Godiyal
Traditional methods of prosthesis fabrication are not efficient and user centric and are made for common purposes without focusing on individual demands of user which leads to rejection of prosthes...

5 February 2021
Verified
Book Chapter
Closed access
PDF file
SBShaurya Bhatt
Shaurya Bhatt
AGAnoop Godiyal
Anoop Godiyal
DJDeepak Joshi
Deepak Joshi
PRPawan Kumar Rakesh
Pawan Kumar Rakesh

1 January 2026 in Engineering Research Express
Verified
Journal Article
Closed access
SBShaurya Bhatt
Shaurya Bhatt
NVNikhil Mayur Verma
Nikhil Mayur Verma
VKVarun Kumar
Varun Kumar
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
DJDeepak Joshi
Deepak Joshi
RKR B Kalia
R B Kalia
Natural fiber-reinforced composites (NFRCs) are gaining increasing attention as sustainable alternatives to synthetic composites in lightweight structural and biomedical applications. This study presents a comparative evaluation of jute/flax-epoxy hybrid composites fabricated using two manufacturing methods: conventional hand layup and vacuum-assisted resin transfer molding (VARTM). Mechanical properties, including tensile strength, flexural strength, impact strength, and hardness, along with physical properties such as density and water absorption, were systematically analyzed. The results revealed that VARTM-fabricated composites exhibited significantly superior mechanical performance compared to hand layup specimens. Tensile and flexural strengths were improved by approximately 43.3% and 36.1%, respectively, while impact strength increased by 34.7%. The enhanced properties were attributed to improved fiber–matrix adhesion, reduced void content, and uniform resin distribution in the VARTM process. Conversely, hand layup composites demonstrated higher water absorption due to increased porosity. Overall, VARTM emerged as a superior fabrication method for high-performance applications, whereas hand layup remains a cost-effective choice for less demanding uses. Importantly, the findings highlight the potential of jute/flax-epoxy composites in biomedical applications, particularly in the development of lightweight and sustainable prosthetic devices.

15 October 2024 in Engineering Research Express
Verified
Journal Article
Closed access
NGNeel Kamal Gupta
Neel Kamal Gupta
SBShaurya Bhatt
Shaurya Bhatt
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
Over the past decade, additive manufacturing has transformed the industry, leading to a range of innovative products. In this study, the acrylonitrile butadiene styrene specimen was produced using the fused deposition modeling process. To assess the effectiveness of additive manufacturing parts in final product development, it’s crucial to establish the optimal drilling process parameters to minimize thrust force and torque. The investigation utilized two different drill geometries. Drilling with an end mill resulted in a 24.22% reduction in thrust force and a 12.37% decrease in torque compared to using a twist drill. Additionally, factors such as orientation, infill density, feed rate, and drill geometry have a significant impact on drilling forces.

1 September 2026 in Engineering Research Express
Verified
Journal Article
Closed access
PDF file
SBShaurya Bhatt
Shaurya Bhatt
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
DJDeepak Joshi
Deepak Joshi
J. Paulo DavimJ. Paulo Davim
J. Paulo Davim
This study presents the design, optimization, and validation of a biomimetic prosthetic foot for unilateral transtibial amputees, with a focus on effective load distribution and energy efficiency throughout the gait cycle. A CAD model, developed using anatomical data from a non-amputee foot, was imported into ANSYS Workbench to evaluate stress distribution and deformation under gait-specific loading conditions, and was subsequently structurally optimized using topology-based techniques to achieve up to 40% weight reduction while maintaining mechanical integrity. The optimized design was fabricated using FDM with polylactic acid filament. To replicate the loading conditions experienced during the heel-strike phases, a custom test jig was developed. Static proof testing was performed using a UTM, following ISO 10328:2016 standards. Experimental results showed a maximum displacement of 14.5 mm during heel strike and 26 mm during toe-off for the 40% optimized foot. Stress analysis revealed a maximum applied load of 1400 N at the ankle-adapter interface, corresponding to an estimated peak stress of ∼45 MPa, with posterior stress accumulation during heel strike and an anterior shift during toe-off. The comparison between simulated and experimental load–displacement curves showed an estimated percentage difference of ∼7.8% in peak load and ∼5% in displacement at peak load ( R 2 ≈ 0.96), confirming that the FE model reproduces the measured static structural response. These results support the static structural feasibility of the optimized design; cyclic loading and further clinical validation are identified as necessary next steps before broader claims of suitability for daily use.

6 September 2026 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
SBShaurya Bhatt
Shaurya Bhatt
PRPawan Kumar Rakesh
Pawan Kumar Rakesh
DJDeepak Joshi
Deepak Joshi