Caesium (Cs) is applied in high power negative hydrogen ion sources to reduce a converter surface’s work function and thus enabling an efficient negative ion surface formation. Inherent drawbacks with the usage of this reactive alkali metal motivate the search for Cs-free alternative materials for neutral beam injection systems in fusion research. In view of a future DEMOnstration power plant, a suitable material should provide a high negative ion formation efficiency and comply with the RAMI issues of the system: reliability, availability, maintainability, inspectability. Promising candidates, like low work function materials (molybdenum doped with lanthanum (MoLa) and LaB 6 ), as well as different non-doped and boron-doped diamond samples were investigated in this context at identical and ion source relevant parameters at the laboratory experiment HOMER. Negative ion densities were measured above the samples by means of laser photodetachment and compared with two reference cases: pure negative ion volume formation with negative ion densities of about and the effect of H − surface production using an in situ caesiated stainless steel sample which yields 2.5 times higher densities. Compared to pure volume production, none of the diamond samples did exhibit a measurable increase in H − densities, while showing clear indications of plasma-induced erosion. In contrast, both MoLa and LaB 6 produced systematically higher densities (MoLa: ×1.60; LaB 6 : ×1.43). The difference to caesiation can be attributed to the higher work functions of MoLa and LaB 6 which are expected to be about 3 eV for both compared to 2.1 eV of a caesiated surface.
Negative hydrogen ion sources for NBI systems at fusion devices rely on the surface conversion of hydrogen atoms and positive ions to negative hydrogen ions. In these sources the surface work function is decreased by adsorption of caesium (work function of 2.1 eV), enhancing consequently the negative ion yield. However, the performance of the ion source decreases during plasma pulses up to one hour, suggesting a deterioration of the work function. Fundamental investigations are performed in a laboratory experiment in order to study the impact of the plasma on the work function of a freshly caesiated stainless steel surface. A work function of 2.1 eV is achieved in the first 10 s of plasma, while further plasma exposure leads to the removal of Cs from the surface and to the change of the work function: a value of around 1.8–1.9 eV is measured after 10–15 min of plasma exposure and then the work function increases, approaching the work function of the substrate (≥4.2 eV) after 5 h. The Cs removal must be counteracted by continuous Cs evaporation, and investigations performed varying the Cs flux towards the surface have shown that a Cs flux of at least 1.5 × 1016 m−2s−1 is required to maintain a work function of 2.1 eV during long plasma exposure at the laboratory experiment.
1 December 2012 in Review of Scientific Instruments
This instrument allows controlled evaporation of the alkali metal cesium over a wide range of evaporation rates. The oven has three unique features. The first is an alkali metal reservoir that uses a dispenser as a cesium source. The heating current of the dispenser controls the evaporation rate allowing generation of an adjustable and stable flow of pure cesium. The second is a blocking valve, which is fully metallic as is the body of the oven. This construction both reduces contamination of the dispenser and enables the oven to be operated up to 300 °C, with only small temperature variations (<5 °C). By minimizing the temperature variation, the built up of the alkali metal at a cold spot is significantly hindered. The last feature is an integral surface ionization detector for measuring and controlling the evaporation rate. The dispenser oven can be easily transferred to the other alkali-metals.
Caesium-covered surfaces are used in negative hydrogen ion sources as a low work function converter for H–/D– surface production. The work function χ of the converter surface is one of the key parameters determining the performance of the ion source. Under idealized conditions, pure bulk Cs has 2.14 eV. However, residual gases at ion source background pressures of 10−7–10−6 mbar and the plasma surface interaction with the hydrogen discharge in front of the caesiated surface dynamically affect the actual surface work function. Necessary fundamental investigations on the resulting χ are performed at a dedicated laboratory experiment. Under the vacuum conditions of ion sources, the incorporation of impurities into the Cs layer leads to very stable Cs compounds. The result is a minimal work function of χvac ≈ 2.75 eV for Cs evaporation rates of up to 10 mg/h independent of substrate material and surface temperature (up to 260 °C). Moreover, a distinct degradation behavior can be observed in the absence of a Cs flux onto the surface leading to a deterioration of the work function by about 0.1 eV/h. However, in a hydrogen discharge with plasma parameters close to those of ion sources, fluxes of reactive hydrogen species and VUV photons impact on the surface which reduces the work function of the caesiated substrate down to about 2.6 eV even without Cs supply. Establishing a Cs flux onto the surface with ΓCs ≈ 1017 m−2 s−1 further enhances the work function obtaining values around 2.1 eV, which can be maintained stable for several hours of plasma exposure. Hence, Cs layers with work functions close to that of pure bulk Cs can be achieved for both H2 and D2 plasmas. Isotopic differences can be neglected within the measurement accuracy of about 0.1 eV due to comparable plasma parameters. Furthermore, after shutting down the Cs evaporation, continuing plasma exposure helps against degradation of the Cs layer resulting in a constant low work function for at least 1 h.