The requirements of ITER neutral beam injectors (1 MeV, 40 A negative deuterium ion current for 1 h) have never been simultaneously attained; therefore, a dedicated Neutral Beam Test Facility (NBTF) was set up at Consorzio RFX (Padova, Italy). The NBTF includes two experiments: SPIDER (Source for the Production of Ions of Deuterium Extracted from Rf plasma), the full-scale prototype of the source of ITER injectors, with a 100 keV accelerator, to investigate and optimize the properties of the ion source; and MITICA, the full-scale prototype of the entire injector, devoted to the issues related to the accelerator, including voltage holding at low gas pressure. The present paper gives an account of the status of the procurements, of the timeline, and of the voltage holding tests and experiments for MITICA. As for SPIDER, the first year of operation is described, regarding the solution of some issues connected with the radiofrequency power, the source operation, and the characterization of the first negative ion beam.
Negative hydrogen ion sources for NBI systems at fusion devices rely on the surface conversion of hydrogen atoms and positive ions to negative hydrogen ions. In these sources the surface work function is decreased by adsorption of caesium (work function of 2.1 eV), enhancing consequently the negative ion yield. However, the performance of the ion source decreases during plasma pulses up to one hour, suggesting a deterioration of the work function. Fundamental investigations are performed in a laboratory experiment in order to study the impact of the plasma on the work function of a freshly caesiated stainless steel surface. A work function of 2.1 eV is achieved in the first 10 s of plasma, while further plasma exposure leads to the removal of Cs from the surface and to the change of the work function: a value of around 1.8–1.9 eV is measured after 10–15 min of plasma exposure and then the work function increases, approaching the work function of the substrate (≥4.2 eV) after 5 h. The Cs removal must be counteracted by continuous Cs evaporation, and investigations performed varying the Cs flux towards the surface have shown that a Cs flux of at least 1.5 × 1016 m−2s−1 is required to maintain a work function of 2.1 eV during long plasma exposure at the laboratory experiment.
1 November 2019 in Review of Scientific Instruments
Negative ion sources for fusion rely on the formation of negative hydrogen (or deuterium) ions by conversion of atomic hydrogen and positive hydrogen ions at a low work function caesiated surface. Cs is thus evaporated into the source to decrease the surface work function, which may change due to the removal and redistribution of Cs during plasma phases. To maintain a temporarily stable low work function during 1 h plasma, continuous evaporation of caesium is required, and this is performed by temperature controlled Cs ovens. The Cs ovens for ELISE (IPP Garching) and SPIDER (Consorzio RFX) are based on the evaporation of liquid Cs from a reservoir located at one end of the oven, which is controlled by the reservoir temperature. The ampoule Cs oven of ELISE is in operation since 2015, allowing for controllable and stable evaporation. The SPIDER oven is based on the ELISE oven although it required significant changes due to the vacuum environment and the oven location (at the back-plate instead of the sidewalls), leading to a different design of the oven and the nozzle. First investigations on the SPIDER oven in a dedicated test stand show that Cs evaporation is controllable, stable, and reproducible.
The cesium ovens for the prototype source of the ITER neutral beam injectors are currently tested in the CAesium Test Stand (CATS) facility, with a background pressure of 10−6 mbar. Different diagnostics are here installed: two Langmuir–Taylor detectors allow us to determine the Cs vapour evaporation rate from the oven and the Cs density at different positions in the vacuum chamber; and laser absorption spectroscopy is used to measure the density integrated over a line of sight and a quartz crystal microbalance to detect the cesium mass deposited in time over a surface. In this paper, we present a model to describe the dynamic equilibrium in the evaporation chamber of CATS with the first oven tested in order to gain information about the Cs sticking coefficient at the walls. The model hence includes sticking and energy accommodation of the Cs atoms to the walls, calculates the flux density at the surfaces, and provides the Cs atom density at any location in the volume. By this model, we simulate the Cs evaporation and the equilibrium density, comparing the modeled results with the experimental data. As a result, a sticking coefficient of 2% is obtained.