Atrial fibrillation (AF) is the most common arrhythmia in horses causing poor performance. As in humans, the condition can be intermittent in nature, known as paroxysmal atrial fibrillation (pAF). This review covers the literature relating to pAF in horses and includes references to the human literature to compare pathophysiology, clinical presentation, diagnostic tools and treatment. The arrhythmia is diagnosed by auscultation and electrocardiography (ECG), and clinical signs can vary from sudden loss of racing performance to reduced fitness or no signs at all. If left untreated, pAF may promote electrical, functional and structural remodeling of the myocardium, thus creating a substrate that is able to maintain the arrhythmia, which over time may progress into permanent AF. Long-term ECG monitoring is essential for diagnosing the condition and fully understanding the duration and frequency of pAF episodes. The potential to adapt human cardiac monitoring systems and computational ECG analysis is therefore of interest and may benefit future diagnostic tools in equine medicine.
6 January 2024 in Journal of Veterinary Cardiology
Spontaneous pulmonary vein (PV) activity triggers atrial fibrillation (AF) in humans. Although AF frequently occurs in horses, the origin remains unknown. This study investigated the structural and electro-anatomical properties of equine PVs to determine the potential presence of an arrhythmogenic substrate. Endocardial three-dimensional electro-anatomical mapping (EnSite Precision) using high-density (HD) catheters was performed in 13 sedated horses in sinus rhythm. Left atrium (LA) access was obtained retrogradely through the carotid artery. Post-mortem, tissue was harvested from the LA, right atrium (RA), and PVs for histological characterization and quantification of ion channel expression using immunohistochemical analysis. Geometry, activation maps, and voltage maps of the PVs were created and a median of four ostia were identified. Areas of reduced conduction were found at the veno-atrial junction. The mean myocardial sleeve length varied from 28 ± 13 to 49 ± 22 mm. The PV voltage was 1.2 ± 1.4 mV and lower than the LA (3.4 ± 0.9 mV, P < 0.001). The fibrosis percentage was higher in PV myocardium (26.1 ± 6.6 %) than LA (14.5 ± 5.0 %, P = 0.003). L-type calcium channel (CaV1.2) expression was higher in PVs than LA (P = 0.001). T-type calcium channels (CaV3.3), connexin-43, ryanodine receptor-2, and small conductance calcium-activated potassium channel-3 was expressed in PVs. The veno-atrial junction had lower voltages, increased structural heterogeneity and areas of slower conduction. Myocardial sleeves had variable lengths, and a different ion channel expression compared to the atria. Heterogeneous properties of the PVs interacting with the adjacent LA likely provide the milieu for re-entry and AF initiation.
1 April 2020 in Journal of Equine Veterinary Science
Second-degree atrioventricular (AV) block is the most common cardiac arrhythmia in horses, affecting 40–90% depending on breed. Usually, the AV blocks occur while the horses are resting and disappear upon exercise and are, therefore, considered to be uneventful for horses. However, if the AV blocks occur frequently, this may result in syncope and collapse. Identifying the cause of second-degree AV block is difficult and often subscribed to high vagal tone. In this report, we present an eight-year-old Quarter horse with a high burden of second-degree AV blocks and multiple collapses. The clinical examination, including neurological examination, blood analysis, 24-h ECG recording and cardiac echocardiography, did not reveal any signs of general or cardiovascular disease besides a high burden of second-degree AV blocks (~300 blocks per hour) and a hyperechoic area in the AV nodal region. An implantable loop recorder (ILR) was inserted to monitor the cardiac rhythm. The ILR detected several consecutive second-degree AV blocks and pauses above 5 s. However, unfortunately, no recordings were available during the collapses. Eventually, the horse was euthanized and the heart inspected. The aortic root was severely cartilaginous and appeared to penetrate the AV node, especially in the His bundle region, possibly explaining the hampered AV conduction. Nevertheless, it is still uncertain if the AV nodal disruption caused the collapses and more knowledge on AV nodal diseases in horses is warranted.
Summary: Atrial fibrillation (AF) is a pathological arrhythmia affecting performance horses and is termed paroxysmal (pAF) when self‐terminating to sinus rhythm. Little is known about pAF as its sporadic nature makes it difficult to diagnose. Therefore, continuous electrocardiographic monitoring devices, such as implantable loop recorders (ILR), are necessary to detect the time of onset and episode duration. This case report presents the detection of pAF in a 9‐year‐old Warmblood horse after successful transvenous electrical cardioversion (TVEC). An ILR continuously monitored the heart rhythm over 28 months and detected 12 episodes of pAF of which two episodes were associated with reduced performance, while others occurred asymptomatically at rest. The estimated episode duration ranged from 6 min to 46.5 h. The antiarrhythmic drug sotalol (2 mg/kg bwt BID PO) was given prior to TVEC and then for 4 weeks. As episodes continued to occur, sotalol was prescribed for another 4 weeks, 6 months after TVEC. Continuous monitoring after TVEC allows for detection of AF recurrence and identification of AF burden, approximate time of onset and possible identification of trigger events. Early diagnosis and antiarrhythmic treatment may prevent a progression to persistent AF.
Background: Paroxysmal atrial fibrillation (pAF) occurs sporadically and can impair athletic performance. Gold standard for diagnosis is surface electrocardiography (ECG), however, this requires AF to be sustained. Implantable loop recorders (ILRs) are routinely used for AF detection in human medicine. While ILR placement has been studied in horses, its AF detection performance is unknown. Objectives: (I) Validation of ILRs for AF detection in horses. (II) Determining pAF incidence using ILRs and estimate the positive predictive value (PPV). Study design: (I) Experimental study; (II) Longitudinal observational study. Methods: (I) Implantation of ILRs in 15 horses with AF and 13 horses in sinus rhythm. Holter ECGs were recorded at: 1, 4, 8, 12 and 16 weeks of AF. The ILR ECGs were compared with surface ECGs to assess diagnostic sensitivity and specificity. (II) Eighty horses (43 Warmbloods, 37 Standardbreds) with ILRs were monitored for 367 days [IQR 208–621]. Results: (I) ILRs detected AF on all recording days, in horses with AF, with a sensitivity of 66.1% (95% CI: 65.8–66.5) and a specificity of 99.99% (95% CI: 99.97–99.99). The sensitivity remained consistent across all time points. (II) The incidence of pAF was 6.3% (5/80). In horses with pAF, the PPV ranged from 8% to 87%. Increased body condition score (BCS > 6/9) was associated with an increased number of false positive episodes ( p = 0.005). Main limitations: (I) Horses were stabled during the ECG recordings, and AF was induced, rather than naturally occurring pAF. (II) Integrated algorithm in this ILR is optimised for AF detection in humans using remote monitors. Additionally, sensing is affected by motion artefacts. Conclusion: The ILR reliably detected AF in resting horses, particularly in horses with normal BCS (6/9). The ILR proved useful to detect pAF and is recommended alongside Holter monitoring for diagnostic workup of horses with suspected pAF.