Atrial fibrillation (AF) is the most common arrhythmia in horses causing poor performance. As in humans, the condition can be intermittent in nature, known as paroxysmal atrial fibrillation (pAF). This review covers the literature relating to pAF in horses and includes references to the human literature to compare pathophysiology, clinical presentation, diagnostic tools and treatment. The arrhythmia is diagnosed by auscultation and electrocardiography (ECG), and clinical signs can vary from sudden loss of racing performance to reduced fitness or no signs at all. If left untreated, pAF may promote electrical, functional and structural remodeling of the myocardium, thus creating a substrate that is able to maintain the arrhythmia, which over time may progress into permanent AF. Long-term ECG monitoring is essential for diagnosing the condition and fully understanding the duration and frequency of pAF episodes. The potential to adapt human cardiac monitoring systems and computational ECG analysis is therefore of interest and may benefit future diagnostic tools in equine medicine.
4 April 2023 in Journal of Cardiovascular Translational Research
Atrial fibrillation (AF) is more prevalent in athletes, and currently, the mechanisms are not fully understood. Atrial fibrillation inducibility and stability was investigated in trained and untrained Standardbred racehorses. The horses underwent echocardiography for evaluation of atrial size. High-density mapping during AF was performed, and the presence of structural remodeling, as well as the expression of inflammatory and pro-inflammatory markers in the atria, was studied. Atrial fibrillation sustained significantly longer after tachypacing in the trained horses, whereas no difference in AF inducibility was found. The untrained horses displayed a significant difference in the AF complexity when comparing right and left atria, whereas such difference was not observed in the trained animals. No evidence of increased structural remodeling or inflammation could be identified. Left atrial dimensions were not significantly increased. The increased AF sustainability in trained horses was not related to fibrosis or inflammation as seen in other animal exercise models. Graphical abstract
Second-degree atrioventricular (AV) block is the most common cardiac arrhythmia in horses, affecting 40–90% depending on breed. Usually, the AV blocks occur while the horses are resting and disappear upon exercise and are, therefore, considered to be uneventful for horses. However, if the AV blocks occur frequently, this may result in syncope and collapse. Identifying the cause of second-degree AV block is difficult and often subscribed to high vagal tone. In this report, we present an eight-year-old Quarter horse with a high burden of second-degree AV blocks and multiple collapses. The clinical examination, including neurological examination, blood analysis, 24-h ECG recording and cardiac echocardiography, did not reveal any signs of general or cardiovascular disease besides a high burden of second-degree AV blocks (~300 blocks per hour) and a hyperechoic area in the AV nodal region. An implantable loop recorder (ILR) was inserted to monitor the cardiac rhythm. The ILR detected several consecutive second-degree AV blocks and pauses above 5 s. However, unfortunately, no recordings were available during the collapses. Eventually, the horse was euthanized and the heart inspected. The aortic root was severely cartilaginous and appeared to penetrate the AV node, especially in the His bundle region, possibly explaining the hampered AV conduction. Nevertheless, it is still uncertain if the AV nodal disruption caused the collapses and more knowledge on AV nodal diseases in horses is warranted.
Horses and humans are among the few mammals susceptible to spontaneous atrial fibrillation (AF), both suffering from high recurrence rates after treatment. Treatment resistance is often attributed to progressive atrial remodeling, but current treatment options fail to effectively address this aspect. Here, we introduce a novel horse model of spontaneous AF to investigate the biological pathway changes in early stages of the disease. Through data-independent acquisition mass spectrometry on biopsies from the right and left atrium and left ventricular chamber of horses with early-stage persistent AF (n = 8) and controls (n = 8), we identify several differentially regulated proteins across all three chambers. Pathway enrichment analyses and histological stainings highlight a significant role of atrial extracellular matrix (ECM) remodeling in early AF. Other key proteomic changes relate to metabolism, contractility, and protein-folding, and overlap with findings from publicly available human datasets. Our results demonstrate that horses and humans share several AF-related proteomic changes, providing translational insights into the early atrial remodeling processes that are likely to contribute to treatment resistance. These protein-level changes could serve as biomarkers or pharmacological targets for preventing AF-associated atrial remodeling and improve treatment outcomes across species.
Aims: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. Methods and results: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: −57 ± 34 ms, P = 0.0002; in the LA: −42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. Conclusion: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.
Background: Paroxysmal atrial fibrillation (pAF) occurs sporadically and can impair athletic performance. Gold standard for diagnosis is surface electrocardiography (ECG), however, this requires AF to be sustained. Implantable loop recorders (ILRs) are routinely used for AF detection in human medicine. While ILR placement has been studied in horses, its AF detection performance is unknown. Objectives: (I) Validation of ILRs for AF detection in horses. (II) Determining pAF incidence using ILRs and estimate the positive predictive value (PPV). Study design: (I) Experimental study; (II) Longitudinal observational study. Methods: (I) Implantation of ILRs in 15 horses with AF and 13 horses in sinus rhythm. Holter ECGs were recorded at: 1, 4, 8, 12 and 16 weeks of AF. The ILR ECGs were compared with surface ECGs to assess diagnostic sensitivity and specificity. (II) Eighty horses (43 Warmbloods, 37 Standardbreds) with ILRs were monitored for 367 days [IQR 208–621]. Results: (I) ILRs detected AF on all recording days, in horses with AF, with a sensitivity of 66.1% (95% CI: 65.8–66.5) and a specificity of 99.99% (95% CI: 99.97–99.99). The sensitivity remained consistent across all time points. (II) The incidence of pAF was 6.3% (5/80). In horses with pAF, the PPV ranged from 8% to 87%. Increased body condition score (BCS > 6/9) was associated with an increased number of false positive episodes ( p = 0.005). Main limitations: (I) Horses were stabled during the ECG recordings, and AF was induced, rather than naturally occurring pAF. (II) Integrated algorithm in this ILR is optimised for AF detection in humans using remote monitors. Additionally, sensing is affected by motion artefacts. Conclusion: The ILR reliably detected AF in resting horses, particularly in horses with normal BCS (6/9). The ILR proved useful to detect pAF and is recommended alongside Holter monitoring for diagnostic workup of horses with suspected pAF.