Gu Xuelian

Dr. Gu Xuelian


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2025 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
TZTianyi Zhang
Tianyi Zhang
GXGu Xuelian
Gu Xuelian
HLHai Li
Hai Li
CWChenchen Wu
Chenchen Wu
NZNiuniu Zhao
Niuniu Zhao
XPXin Peng
Xin Peng
A lumbar spine statistical shape model (SSM) was developed to explain morphological differences in a population with adolescent idiopathic scoliosis (AIS). Computed tomography (CT) was used to collect data on the lumbar spine vertebrae and curvature of 49 subjects. The CT data were processed by segmentation, landmark identification, and template mesh mapping, and then SSMs of the individual vertebrae and entire lumbar spine were established using generalized Procrustes analysis and principal component analysis (PCA). Scaling was the most prevalent variation pattern. The weight coefficient was optimized using the Levenberg–Marquardt (LM) algorithm, and multiple regression analysis was used to establish a prediction model for age, sex, height, and body mass index (BMI). The effectiveness of the SSM and prediction model was quantified based on the root-mean-square error (RMSE). An automatic measurement method was developed to measure the anatomical parameters of the geometric model. The lumbar vertebrae size was significantly affected by height, sex, BMI, and age, with men having lower vertebral height than women. The trends in anatomical parameters were consistent with previous studies. The vertebral SSMs characterized the shape changes in the processes, while the lumbar spine SSM described alignment changes associated with translatory shifts, kyphosis, and scoliosis. Quantifying anatomical variation with SSMs can inform implant design and assist clinicians in diagnosing pathology and screening patients. Lumbar spine SSMs can also support biomechanical simulations of populations with AIS.

5 December 2021 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
XQXiaojian Qiu
Xiaojian Qiu
GXGu Xuelian
Gu Xuelian
CLChenyang Liu
Chenyang Liu
HTHao Tian
Hao Tian
RCRuina Chen
Ruina Chen
YLYuanyuan Li
Yuanyuan Li

25 September 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
GXGu Xuelian
Gu Xuelian
YQYongxiang Qi
Yongxiang Qi
AEArthur G. Erdman
Arthur G. Erdman
A computational evaluation approach to the wall apposition of a cerebral mechanical emboli retrieval device (MERD) is presented. The typical enclosed multilattice structure, manufactured from the thin-walled Nitinol tube, consists of repeated “V”-shaped unit cells. During interventional thrombectomy, the MERD system is delivered inside an artery stenosis segment to capture emboli and restore cerebral blood flow. The wall apposition, which deteriorates during embolus capture, occurs during system migration along the tortuous intracranial vessel. The commercial finite element analysis (FEA) solver ABAQUS 6.10 Standard and user subroutine (UMAT/Nitinol) are utilized to study the ability to remain in close contact with the curved vessel wall during migration. In this numerical analysis, the influence of the contacting interference loadings on structure deformation and strain field distribution is obtained and analyzed. The results indicate that the middle segment of the MERD seriously contracts or collapses inside the curved vessel. In addition, the peak strain is in the apex flow-prone region and maintains at the safe range.

21 February 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
PLPeng Liang
Peng Liang
GZGaiping Zhao
Gaiping Zhao
GXGu Xuelian
Gu Xuelian
ZCZhi Chen
Zhi Chen
SXShaorong Xu
Shaorong Xu
WLWentao Liu
Wentao Liu
Background: Arthroscopic shavers play an indispensable role in arthroscopic debridement. They have exquisite structures and similar designs. The purpose of this study was to establish a reproducible testing protocol to compare the resection performance and the quality (tensile strength, torsional strength, and corrosion resistance) of different arthroscopic shavers with comparable designs. We hypothesized that there could be little difference in resection performance and quality between these shavers. Methods: Incisor Plus Blade (IPB; Smith & Nephew, Andover, MA) and Double Serrated Plus Blade (DSPB; BJKMC, Shanghai, China) were selected for resection performance and quality test. For resection performance testing, the resection torque, which is the minimum torque required to cut off silicone blocks with the same cross-sectional area, was measured to evaluate the resection performance of shaver blades when the other factors remain the same. For quality testing, tensile and torsion tests of the shavers’ joint part were performed, and ultimate failure load and maximum torque were measured and compared. The corrosion resistance of these blades was assessed by the boiling water test based on the ISO13402. Results: No significant difference existed in the resection torque between the shaver blades of IPB and DSPB (P = 0.54). To the failure load of shavers’ joint parts, IPB was significantly higher than DSPB, both in the outer and inner blades (P < 0.0001). The maximum torque of the joint part had no significant difference between IPB and DSPB (for inner blades P = 0.60 and outer blades P = 0.94). The failure load (for both IPB and DSPB P < 0.0001) and maximum torque (for IPB P = 0.0475 and DSPB P = 0.015) of the inner blades were higher than those of the outer blades. No blemishes were observed on the surface of the blades after corrosion resistance tests. Conclusions: This study provided some new methods to evaluate the resection performance and quality of different shavers. The resection performance, the torsional strength of the joint part, and the corrosion resistance of IPB and DSPB may show comparable properties, whereas the tensile strength of the shavers’ joint part showed some level of difference.

10 July 2020 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
GXGu Xuelian
Gu Xuelian
TWTaotao Wang
Taotao Wang
KZKang Zheng
Kang Zheng
ZJZiang Jiang
Ziang Jiang
HJHongyan Jiang
Hongyan Jiang

19 November 2018 in Journal of Medical Devices
Verified
Journal Article
Closed access
PDF file
GXGu Xuelian
Gu Xuelian
FHFangqiu Hu
Fangqiu Hu
CLChi-Lun Lin
Chi-Lun Lin
AEArthur G. Erdman
Arthur G. Erdman
LLLicheng Lu
Licheng Lu
Needle biopsy is a routine medical procedure for examining tissue or biofluids for the presence of disease using standard methods of pathology. The finite element analysis (FEA) methodology can provide guidance for optimizing the geometric parameters. The needle biopsy is simulated and analyzed while varying the needle angle, the aperture size and the slice-push ratio k. The results indicate that tissue reaction force in the axial direction of needle gradually decreases, and the stress and strain are more concentrated at the tip of needle with the increases of tip angle; the tissue reaction force decreases, and the torque increases while the slice-push ratio increases; and higher slice–push ratio can increase the peak stress concentration on the cutting edge and deformation of tissue; in the process of core needle cutting, increasing slice–push ratio can reduce the tissue reaction force significantly. While the aperture on distal wall of outer cannula becomes wider, the tissue reaction force increases significantly, and the cutting process will be more unstable. The results have the potential to provide important insight for improving the needle biopsy design process.