This study presents an investigation of the effect of building envelope, especially glass facade buildings on cooling energy usage and thermal comfort. An office building was modeled with various window-to-wall ratio (WWR) using panasap glass with SC=0.58 in order to analyze the effect of the WWR addition on cooling energy usage and comfort temperature. The result suggested that the average increase of the cooling energy usage is about 5.67% per 10% WWR addition, and of the operative temperature ranges from 0.350C to 0.560C per 10% WWR addition. Moreover, the building with above 20% WWR doesn’t provide comfort temperature.
Lighting control systems (LCSs) play important roles in maintaining visual comfort and energy savings in buildings. This paper presents a prototype LCS using LabVIEW with real-time high dynamic range images and a digital multiplex controller to brighten lamps sequentially to provide visual comfort. The prototype is applied to a scaled classroom model with three schemes involving different activities and needs: writing and reading, requiring a uniform luminance of approximately 100 cd/m2, teaching using a whiteboard, requiring an illuminance of approximately 120 cd/m2 for the whiteboard and 60 cd/m2 for the desks, and drawing and art activities focused on the center of the room, requiring an illuminance of approximately 100 cd/m2 for the center area and 50 cd/m2 for the background area. For each scheme, two conditions are presented: one in which the room is treated as a closed room without windows, and the one in which the room has a large window on one wall that enables daylight to penetrate the room. The prototype works well with both schemes and provides different combinations of lamp brightness levels, starting from 10% to 60%, based on the activities and required luminance, and can save around 73–82% of electricity. The presence of daylight does not always result in more energy savings, as the brightness contrast for visual comfort needs to be considered.
27 June 2018 in Journal of Urban and Environmental Engineering
This paper presents the study of the performance of building-integrated photovoltaic (BIPV) applied on vertical building envelope as overhang shading devices on energy saving. In Indonesia, where solar energy is abundant, the utilization of PV system as renewable energy is very potential, especilly in remote area. However, in the urban core of Indonesia, the utilization of PV system is not yet economically viable. In this study, six BIPV models with different design of PV panel shading devices were simulated using weather file of Jakarta, an urban core of Indonesia. The results show that installing fewer PV panel shading devices on building façade with greater distance is more effective than installing more PV panel shading device with less distance. The LCOE (levelized cost of electricity) of all models that is lower than the national grid electricity cost indicates that BIPV could be economically profitable if it is designed properly.
15 February 2022 in Journal of Asian Architecture and Building Engineering
The research was specifically focused on the renewable energy factors associated with thousands of hexagonal micro-module wind turbines, hexagonal solar cell modules, and hexagonal modules for solar-reflecting pipes. This involved the utilization of windmills and solar cells specifically designed in a non-structural facade of the front building envelope through a double facade technique. Moreover, electrical energy was obtained from each windmill module while extra renewable electricity from abundant sunlight was acquired through the hexagonal modules of the solar cells (photovoltaic) designed vertically on the building facade. But this current research only focuses on hexagonal wind turbines. ANSYS Fluent 12.0 simulated software and numerical analysis were used to optimize and redesign the wind turbine blades in order to obtain more electricity from one micro-module hexagonal wind turbine. The results showed that this design was able to produce 2.66 Watts per wind turbine compared to the 0.12 Watt from the previous design. The TSR was also found to be 0.5 and its power coefficient value (CP) of 0.4525 was observed to be much higher than the 0.0343 from the previous design. Therefore, means multilevel buildings have the ability to harvest sustainable greenery energies from such a smart architectural façade.
1 June 2020 in IOP Conference Series: Earth and Environmental Science
This study investigated the potential impacts of wind pressure and incident solar radiation on a building tilted façade installed with micro wind turbine and photovoltaic panels as a second skin façade for generating electricity. The wind pressure will affect wind turbine rotation, and solar radiation will affect the energy produced by the photovoltaic. The study used simulation modeling software to analyze the wind pressure and solar radiation received on the tilted façade. The research found that the force received by the tilted façade is more significant than that received by the 90° tilted fagade. The smaller the tilted-angle of the fagade, the more radiation received by the PV panel. Conversely, the larger tilted-angle of the building façade, the less radiation received by the photovoltaic, despite the wind pressure received by the wind turbine being higher than that received by the 90° tilt façade. However, the more radiation received by the fagade, the more heat received by the building.