1 April 2020 in IOP Conference Series: Earth and Environmental Science
Horizontal Light Pipe (HLP) is one of a light transport system that can guide daylight deeper into building interiors. Improvement of HLP’s light distribution by installing an egg-crate reflector at its opening distribution was conducted. The study’s aim was to evaluate and explain the daylight performance of HLP with an egg-crate reflector at office space in the tropics. Experiment with physical scaled model 1:5 was used as a research method. Illuminance value, Daylight Factor (DF), uniformity ratio and diversity of illuminance of an office space lit by side window (base case) were compared to the office space lit by side window and HLP with an egg-crate reflector (case), simultaneously with daylighting standards. The results showed that HLP with egg-crate reflector improved daylight level and distribution. Improvement of DF and illuminance level were in the range of 16.6 % to 56.6 %. The uniformity ratio of the base case was in the range of 0.35 to 0.45, while in the case was in the range of 0.48 to 0.66. The diversity of illuminance of the base case at a low altitude of the sun (15:00) exceeded 5:1 while in the case was kept lower than 5:1 at all the measurement time.
15 February 2022 in Journal of Asian Architecture and Building Engineering
The research was specifically focused on the renewable energy factors associated with thousands of hexagonal micro-module wind turbines, hexagonal solar cell modules, and hexagonal modules for solar-reflecting pipes. This involved the utilization of windmills and solar cells specifically designed in a non-structural facade of the front building envelope through a double facade technique. Moreover, electrical energy was obtained from each windmill module while extra renewable electricity from abundant sunlight was acquired through the hexagonal modules of the solar cells (photovoltaic) designed vertically on the building facade. But this current research only focuses on hexagonal wind turbines. ANSYS Fluent 12.0 simulated software and numerical analysis were used to optimize and redesign the wind turbine blades in order to obtain more electricity from one micro-module hexagonal wind turbine. The results showed that this design was able to produce 2.66 Watts per wind turbine compared to the 0.12 Watt from the previous design. The TSR was also found to be 0.5 and its power coefficient value (CP) of 0.4525 was observed to be much higher than the 0.0343 from the previous design. Therefore, means multilevel buildings have the ability to harvest sustainable greenery energies from such a smart architectural façade.
1 May 2018 in IOP Conference Series: Earth and Environmental Science
Courtyard in a low-cost flat in the tropics provides daylight but it is usually protected with a corridor to control the solar radiation. Surrounded by a shaded corridor, daylight level of the adjacent dwelling rooms around the courtyard are reduced. Modification of courtyard wall by integrating a sloped light shelf is proposed to improve the daylight level on dwelling room and control excessive light penetration at the corridor. Experiment with simulation as a tool was used as a research method. Illuminance value, Daylight Factor and uniformity ratio of the base case, a courtyard wall design in a typical low-cost flat in Surabaya (latitude 7º15'55''S) using louver and case, a proposed courtyard wall design using sloped light shelf were compared, simultaneously with daylighting standards. The results demonstrated that courtyard wall modification reduced excessive average illuminance on the corridor in the range of 41% to 57.1% and improved average illuminance in dwelling room in the range of 0.9% to 19.2%. The proposed courtyard wall also increased illuminance uniformity ratio in both corridor and dwelling room. In order to improve daylight quantity and quality, a courtyard wall with sloped light shelf can be applied on a low-cost flat in the tropics.