Alexandre Abizaid

Dr. Alexandre Abizaid


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2010 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
PDF file
AAAlexandre Abizaid
Alexandre Abizaid
JCJ. Ribamar Costa
J. Ribamar Costa

1 June 2007 in European Heart Journal
Verified
Journal Article
Closed access
PDF file
DSDimytri A. Siqueira
Dimytri A. Siqueira
AAAlexandre Abizaid
Alexandre Abizaid
JCJose de Ribamar Costa
Jose de Ribamar Costa
FFFausto Feres
Fausto Feres
LMLuiz A. Mattos
Luiz A. Mattos
JSJ. Eduardo M.R. Sousa
J. Eduardo M.R. Sousa
Aim Late-acquired incomplete stent apposition (ISA) has been documented after drug-eluting stent (DES) implantation; however, its clinical role remains controversial. We sought to investigate the incidence and long-term clinical consequences of late ISA after implantation of sirolimus- (SES) or paclitaxel-eluting stent (PES) in a non-selected population. Methods and results From our database, we analysed 195 consecutive patients who underwent DES placement (175 with SES and 20 with PES) into native artery lesions and had serial intravascular ultrasound studies (IVUS) performed at index procedure and after 6–8 months. They were clinically followed for 29 ± 15 months (median of 24.3 months, interquartile range 18.1–31.6 months). Late ISA was defined as separation of at least one stent strut from the vessel wall in a segment without a side-branch and where the immediate post-implantation IVUS revealed complete apposition of stent struts. We identified 10 patients (5.1%) with late ISA, three patients after PES, and seven patients after SES implantation. ISA was localized almost exclusively at body of the stents (nine out of 10 cases). Mean ISA volume and length were 44.5 ± 41.9 mm3 and 7.4 ± 11 mm, respectively. There was a marked increase in vessel volume from 416.0 ± 163.9 mm3 at baseline to 514.4 ± 247.9 mm3 at follow-up ( P = 0.001) with no significant change in plaque volume (232.4 ± 52.7 at baseline and 226.4 ± 22.3 mm3 at follow-up, P = 0.3) in patients who presented with late-acquired ISA. During the follow-up period, one patient with SES and one patient with PES who presented late-acquired ISA had late stent thrombosis and acute myocardial infarction. Conclusion Late-acquired ISA was observed in 5.1% of patients after DES implantation and is related to regional vessel positive remodelling. The relationship between late-acquired ISA and long-term adverse outcomes (e.g. stent thrombosis) requires further analysis.

1 March 2016 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
AAAlexandre Abizaid
Alexandre Abizaid
RCRicardo A. Costa
Ricardo A. Costa
JSJoachim Schofer
Joachim Schofer
JOJohn Ormiston
John Ormiston
MMMichael Maeng
Michael Maeng
SVStefan Verheye
Stefan Verheye

13 October 2020 in Arquivos Brasileiros de Cardiologia
Verified
Journal Article
Open access
PDF file
FTFlavio Tarasoutchi
Flavio Tarasoutchi
MMMarcelo Westerlund Montera
Marcelo Westerlund Montera
ARAuristela Isabel de Oliveira Ramos
Auristela Isabel de Oliveira Ramos
RSRoney Orismar Sampaio
Roney Orismar Sampaio
VRVitor Emer Egypto Rosa
Vitor Emer Egypto Rosa
JSJose Saraiva
Jose Saraiva
1. Introduction There are currently a wide modalities of interventional strategies – both transcatheter and surgical – which can be indicated for patients with valvular heart diseases (VHD), with the objective of reducing the morbidity and mortality. The correct timing for indication and the type of interventional treatment are linked to the precise anatomical and functional diagnosis of the VHD, and comprehensive global evaluation of the patient. The 2020 Update of the Brazilian Guidelines for VHD, in addition to compiling [...] 1. Introduction There are currently a wide modalities of interventional strategies – both transcatheter and surgical – which can be indicated for patients with valvular heart diseases (VHD), with the objective of reducing the morbidity and mortality. The correct timing for indication and the type of interventional treatment are linked to the precise anatomical and functional diagnosis of the VHD, and comprehensive global evaluation of the patient. The 2020 Update of the Brazilian Guidelines for VHD, in addition to compiling

24 April 2025 in European Heart Journal
Verified
Journal Article
Open access
SFSimone Fezzi
Simone Fezzi
BSBruno Scheller
Bruno Scheller
BCBernardo Cortese
Bernardo Cortese
FAFernando Alfonso
Fernando Alfonso
RJRaban Jeger
Raban Jeger
PSPatrick Serruys
Patrick Serruys
The Drug Coated Balloon Academic Research Consortium project originated from the lack of standardization and comparability between studies using drug-coated balloons in the treatment of obstructive coronary artery disease. This document is a collaborative effort between academic research organizations and percutaneous coronary intervention societies in Europe, the USA, and Asia. This consensus sought to standardize study designs and endpoints for clinical trials involving drug-coated balloons, including defining angiographic, intravascular, and non-invasive imaging methods for lesion assessment, alongside considerations for post-revascularization pharmaco-therapy. The concept of ‘blended therapy’, which advocates for combining device strategies, is also discussed. This paper delineates study types, endpoint definitions, follow-up protocols, and analytical approaches, aiming to provide consistency and guidance for interventional cardiologists and trialists.

1 January 2004 in European Heart Journal
Verified
Journal Article
Closed access
AAAlexandre Abizaid
Alexandre Abizaid
Patients with diabetes mellitus have less favourable outcomes after percutaneous coronary intervention (PCI) than non-diabetics. We performed a subgroup analysis of the multicentre RAVEL trial to examine the impact of the sirolimus-eluting stent (SES) on outcomes in diabetic patients. The RAVEL study randomized 238 patients to treatment with either sirolimus-eluting or bare metal stents. Forty-four patients were diabetic; 19 received sirolimus-eluting stents and 25 were treated with bare metal stents. The differences in outcomes between diabetic and non-diabetic patients treated with SES (n=101) were also assessed. Follow-up angiography was performed at 6 months. Major adverse cardiac events (MACE) defined as death, myocardial infarction (MI), or target lesion revascularization (TLR) were analysed at 12-month follow-up. Six-month in-stent late lumen loss was significantly lower for the diabetic SES than the bare stent group (0.07+/-0.2 vs 0.82+/-0.5mm; P<0.001) and similar to that in non-diabetics treated with SES (-0.03+/-0.27mm). There was zero restenosis in the SES groups (diabetic and non-diabetic) compared to a 42% rate in the diabetic population assigned to bare metal stents (P=0.001). After 12 months, there was one non-Q-wave MI and one non-cardiac death in the diabetic SES group, while 12 patients in the bare metal stent group had MACE (one death, two MI, nine TLR) (P=0.01)-an event-free survival rate of 90% vs 52%, respectively (P<0.01). There were no TLRs in both SES groups compared to 36% rate in the diabetic bare metal stent group (P=0.007). Conclusion Diabetics treated with SES were associated with a virtual abolition of neointimal proliferation and low event rates at long-term follow-up.