Pablo Acedo

Prof. Dr. Pablo Acedo

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2015 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
BJBorja Jerez
Borja Jerez
PAPablo Acedo
Pablo Acedo
In this paper, a multiheterodyne architecture for molecular dispersion spectroscopy based on a coherent dual-comb source generated using a single continuous wave laser and electro-optic modulators is presented and validated. The phase-sensitive scheme greatly simplifies previous dual-comb implementations by the use of an electro-optic dual comb and by phase-locking all the signal generators of the setup eliminating, in this way, the necessity of any reference optical path currently mandatory in absorption-based instruments. The architecture is immune to the classical baseline and normalization problems of absorption-based analyzers and provides an output linearly dependent on the gas concentration. In addition, the simultaneous parallel multi-wavelength measurement approach has the ability to deliver an improved output bandwidth (measurement speed) over gas analyzers based on tunable lasers.

26 October 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
Mahmoud Amouzadeh TabriziMahmoud Amouzadeh Tabrizi
Mahmoud Amouzadeh Tabrizi
JFJuan P. Fernández-Blázquez
Juan P. Fernández-Blázquez
DMDahiana Mojena Medina
Dahiana Mojena Medina
PAPablo Acedo
Pablo Acedo

25 February 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Mahmoud Amouzadeh TabriziMahmoud Amouzadeh Tabrizi
Mahmoud Amouzadeh Tabrizi
PAPablo Acedo
Pablo Acedo
Worldwide, human health is affected by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Hence, the fabrication of the biosensors to diagnose SARS-CoV-2 is critical. In this paper, we report an electrochemical impedance spectroscopy (EIS)-based aptasensor for the determination of the SARS-CoV-2 receptor-binding domain (SARS-CoV-2-RBD). For this purpose, the carbon nanofibers (CNFs) were first decorated with gold nanoparticles (AuNPs). Then, the surface of the carbon-based screen-printed electrode (CSPE) was modified with the CNF–AuNP nanocomposite (CSPE/CNF–AuNP). After that, the thiol-terminal aptamer probe was immobilized on the surface of the CSPE/CNF–AuNP. The surface coverage of the aptamer was calculated to be 52.8 pmol·cm−2. The CSPE/CNF–AuNP/Aptamer was then used for the measurement of SARS-CoV-2-RBD by using the EIS method. The obtained results indicate that the signal had a linear–logarithmic relationship in the range of 0.01–64 nM with a limit of detection of 7.0 pM. The proposed aptasensor had a good selectivity to SARS-CoV-2-RBD in the presence of human serum albumin; human immunoglobulins G, A, and M, hemagglutinin, and neuraminidase. The analytical performance of the aptasensor was studied in human saliva samples. The present study indicates a practical application of the CSPE/CNF-AuNP/Aptamer for the determination of SARS-CoV-2-RBD in human saliva samples with high sensitivity and accuracy.

8 April 2015 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
PMPedro Martin-Mateos
Pedro Martin-Mateos
MRMarta Ruiz-Llata
Marta Ruiz-Llata
JPJulio Posada-Roman
Julio Posada-Roman
PAPablo Acedo
Pablo Acedo
Optical frequency combs (OFCs) generated through the modulation of continuous-wave lasers offer higher power per component, simple comb spacing control, and lower complexity and cost than traditional OFCs. By these reasons, they are an interesting optical source for spectrometers. In this letter, a dual-comb architecture based on two OFCs generated from the same laser using optical phase modulators is presented. The system features a new placement for the spectroscopic sample that increases the versatility, robustness, and stability of the instrument without requiring any reconfiguration for carrying out different types of measurement. Besides this, a self-referenced detection setup based on digital phase sensitive multitone detection improves the SNR of the previous approaches offering more flexibility in its configuration and high data output rate. The proposed architecture is validated by measuring a ro-vibrational absorption feature of HCN at 1544.51 nm and characterizing the spectral response of a fiber-coupled Fabry-Perot filter.


12 June 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
PAPablo Acedo
Pablo Acedo
In this paper, a technique for molecular dispersion spectroscopy based on heterodyne phase-sensitive detection is presented. The method offers immunity to fluctuations of the received optical power and an output linearly dependent of the gas concentration. Besides this, an analytical model for the propagation of light in gaseous samples has been developed enabling calibration-free operation. The proposed architecture has been tested and experimentally validated using methane as target gas.