Pedro Martín-Mateos

Dr. Pedro Martín-Mateos

Sensors and Instrumentation Techniques Group, Universidad Carlos III de Madrid, Madrid, Spain

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2015 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
BJBorja Jerez
Borja Jerez
PAPablo Acedo
Pablo Acedo
In this paper, a multiheterodyne architecture for molecular dispersion spectroscopy based on a coherent dual-comb source generated using a single continuous wave laser and electro-optic modulators is presented and validated. The phase-sensitive scheme greatly simplifies previous dual-comb implementations by the use of an electro-optic dual comb and by phase-locking all the signal generators of the setup eliminating, in this way, the necessity of any reference optical path currently mandatory in absorption-based instruments. The architecture is immune to the classical baseline and normalization problems of absorption-based analyzers and provides an output linearly dependent on the gas concentration. In addition, the simultaneous parallel multi-wavelength measurement approach has the ability to deliver an improved output bandwidth (measurement speed) over gas analyzers based on tunable lasers.

12 June 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
PAPablo Acedo
Pablo Acedo
In this paper, a technique for molecular dispersion spectroscopy based on heterodyne phase-sensitive detection is presented. The method offers immunity to fluctuations of the received optical power and an output linearly dependent of the gas concentration. Besides this, an analytical model for the propagation of light in gaseous samples has been developed enabling calibration-free operation. The proposed architecture has been tested and experimentally validated using methane as target gas.

15 May 2017 in Analytical Chemistry
Verified
Journal Article
Closed access
PMPedro Martín-Mateos
Pedro Martín-Mateos
JHJakob Hayden
Jakob Hayden
PAPablo Acedo
Pablo Acedo
BLBernhard Lendl
Bernhard Lendl

26 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AGAndreas Genner
Andreas Genner
PMPedro Martín-Mateos
Pedro Martín-Mateos
HMHarald Moser
Harald Moser
IAInstitute of Chemical Technologies and Analytics
Institute of Chemical Technologies and Analytics
A quantum cascade laser-based sensor for ambient air monitoring is presented and five gases, affecting the air quality, can be quantified. The light sources are selected to measure CO, NO, NO2, N2O and SO2. The footprint of the measurement setup is designed to fit in two standard 19” rack (48 cm × 65 cm) with 4 height units (18 cm) whereas one is holding the optical components and the other one contains the electronics and data processing unit. The concentrations of the individual analytes are measured using 2f-Wavelength Modulation Spectroscopy (2f-WMS) and a commercially available multipass gas cell defines the optical path. In addition, CO can also be measured with a dispersion-based technique, which allows one to cover a wider concentration range than 2f-WMS. The performance of this prototype has been evaluated in the lab and detection limits in the range of 1ppbv have been achieved. Finally, the applicability of this prototype for ambient air monitoring is shown in a five-week measurement campaign in cooperation with the Municipal Department for Environmental Protection (MA 22) of Vienna, Austria.

4 April 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
BJBorja Jerez
Borja Jerez
PLPedro Largo-Izquierdo
Pedro Largo-Izquierdo
PAPablo Acedo
Pablo Acedo
Electro-optic dual-comb spectrometers have proved to be a promising technology for sensitive, high-resolution and rapid spectral measurements. Electro-optic combs possess very attractive features like simplicity, reliability, bright optical teeth, and typically moderate but quickly tunable optical spans. Furthermore, in a dual-comb arrangement, narrowband electro-optic combs are generated with a level of mutual coherence that is sufficiently high to enable optical multiheterodyning without inter-comb stabilization or signal processing systems. However, this valuable tool still presents several limitations; for instance, on most systems, absolute frequency accuracy and long-term stability cannot be guaranteed; likewise, interferometer-induced phase noise restricts coherence time and limits the attainable signal-to-noise ratio. In this paper, we address these drawbacks and demonstrate a cost-efficient absolute electro-optic dual-comb instrument based on a frequency stabilization mechanism and a novel adaptive interferogram acquisition approach devised for electro-optic dual-combs capable of operating in real-time. The spectrometer, completely built from commercial components, provides sub-ppm frequency uncertainties and enables a signal-to-noise ratio of 10000 (intensity noise) in 30 seconds of integration time.

2 September 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PMPedro Martín-Mateos
Pedro Martín-Mateos
DČDovilė Čibiraitė-Lukenskienė
Dovilė Čibiraitė-Lukenskienė
RBRoberto Barreiro
Roberto Barreiro
CDCristina de Dios
Cristina de Dios
ALAlvydas Lisauskas
Alvydas Lisauskas
PAPablo Acedo
Pablo Acedo
In this paper, a terahertz hyperspectral imaging architecture based on an electro-optic terahertz dual-comb source is presented and demonstrated. In contrast to single frequency sources, this multi-heterodyne system allows for the characterization of the whole spectral response of the sample in parallel for all the frequency points along the spectral range of the system. This hence provides rapid, highly consistent results and minimizes measurement artifacts. The terahertz illumination signal can be tailored (in spectral coverage and resolution) with high flexibility to meet the requirements of any particular application or experimental scenario while maximizing the signal-to-noise ratio of the measurement. Besides this, the system provides absolute frequency accuracy and a very high coherence that allows for direct signal detection without inter-comb synchronization mechanisms, adaptive acquisition, or post-processing. Using a field-effect transistor-based terahertz resonant 300 GHz detector and the raster-scanning method we demonstrate the two-dimensional hyperspectral imaging of samples of different kinds to illustrate the remarkable capabilities of this innovative architecture. A proof-of-concept demonstration has been performed in which tree leaves and a complex plastic fragment have been analyzed in the 300 GHz range with a frequency resolution of 10 GHz.