Adrián García Osuna

Mr. Adrián García Osuna


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MRMaria Del Carmen Jiménez Ramos
Maria Del Carmen Jiménez Ramos
JGJavier García-López
Javier García-López
AOAdrián García Osuna
Adrián García Osuna
IVIvan Vila
Ivan Vila
ECEsteban Currás
Esteban Currás
GPGiulio Pellegrini
Giulio Pellegrini
Gain suppression induced by excess carriers in Low Gain Avalanche Detectors (LGADs) has been investigated using 3 MeV protons in a nuclear microprobe. In order to modify the ionization density inside the detector, Ion Beam Induced Current (IBIC) measurements were performed at different proton beam incidence angles between 0° and 85°. The experimental results have been analyzed as a function of the ionization density projected on the multiplication layer, finding that the increase of ionization density leads to greater gain suppression. For bias voltages close to the gain onset value, this decrease in gain results into a significant distortion of the transient current waveforms measured by the Time-Resolved IBIC (TRIBIC) technique due to a deficit in the secondary holes component. For angles of incidence such that the Bragg peak falls within the sensitive volume of the detector, the formation of microplasmas modifies the behavior of the gain curves, producing an abrupt decrease in gain as the angle increases.

28 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DBDiana Bachiller-Perea
Diana Bachiller-Perea
JGJavier García-López
Javier García-López
MRMaria Del Carmen Jiménez Ramos
Maria Del Carmen Jiménez Ramos
FGFaustino Gómez
Faustino Gómez
CFCeleste Fleta
Celeste Fleta
CGConsuelo Guardiola
Consuelo Guardiola
New silicon 3-D-microdetectors have been developed to perform microdosimetry measurements for applications in hadron therapy. In this work, the charge collection efficiency (CCE) of an improved second generation of microdetectors having two different thicknesses (10 and 20 μm) and a diameter of 25 μm has been studied by means of the ion beam induced charge (IBIC) technique. New methods to study the active volume and the CCE of microdosimeters are proposed and verified here. The results show that, for this new generation of microdetectors, the CCE is 100% for radial distances up to 10.2 μm from the center of the device, and it rapidly decays between 10.2 μm and the detector edge. The characterization of the CCE conducted here will allow us to completely explain the energy spectra obtained during the microdosimetry studies performed in clinical centers.