He Yongning

Dr. He Yongning


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in International Journal of Refrigeration
Verified
Journal Article
Closed access
YZYeqiang Zhang
Yeqiang Zhang
HYHe Yongning
He Yongning
YWYanling Wang
Yanling Wang
XWXuehong Wu
Xuehong Wu
MJMingzheng Jia
Mingzheng Jia
YGYi Gong
Yi Gong

1 December 2015 in International Journal of Refrigeration
Verified
Journal Article
Closed access
HYHe Yongning
He Yongning
FCFeng Cao
Feng Cao
LJLei Jin
Lei Jin
Xiaolin WangXiaolin Wang
Xiaolin Wang
ZXZiwen Xing
Ziwen Xing

1 December 2018 in Applied Thermal Engineering
Verified
Journal Article
Closed access
HYHe Yongning
He Yongning
LXLinfen Xing
Linfen Xing
YZYeqiang Zhang
Yeqiang Zhang
JZJun Zhang
Jun Zhang
FCFeng Cao
Feng Cao
ZXZiwen Xing
Ziwen Xing

23 January 2023 in Energy and Buildings
Verified
Journal Article
Closed access
HYHe Yongning
He Yongning
Huihong WuHuihong Wu
Huihong Wu
KXKe Xu
Ke Xu
YZYeqiang Zhang
Yeqiang Zhang
TWTao Wang
Tao Wang
TJTingxiang Jin
Tingxiang Jin

14 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HYHe Yongning
He Yongning
Huihong WuHuihong Wu
Huihong Wu
YZYeqiang Zhang
Yeqiang Zhang
TJTingxiang Jin
Tingxiang Jin
ZXZiwen Xing
Ziwen Xing
An organic Rankine cycle (ORC) system is an efficient technology for generating power from low-grade thermal sources. Twin screw expanders are widely used in ORC systems. Pressure loss caused by a suction port influences the suction process and the system performance. In this paper, the effects of suction ports on twin screw expander performance are experimentally investigated. The pressure loss value of R245fa is measured under different working conditions, and its effects on the suction coefficient are discussed. Results show that a lower rotation speed results in a lower pressure loss value and a higher suction coefficient under certain working conditions. Increasing the suction pressure leads to a higher pressure loss value but a lower pressure loss ratio. Discharge pressure has little effect on the suction process.

19 December 2025 in Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy
Verified
Journal Article
Closed access
HYHe Yongning
He Yongning
SWSu’AO Wang
Su’AO Wang
WCWenliang Cao
Wenliang Cao
XZXihang Zhao
Xihang Zhao
MLMingwen Luo
Mingwen Luo
BHBin Hu
Bin Hu
The high temperature heat pump (HTHP) plays an important role in improving the efficiency of electric heating and thereby achieving a peaking and then reduction of global carbon emissions. Applications of HTHP in industrial heating is able to replace the boilers directly. Refrigerant has significant impact on system performance and then the efficiency of industrial heating. Low global warming potential (GWP) refrigerants R600, R601, R601a, R1224yd(Z), R1233zd(E), R1234ze(Z) and R1336mzz(Z) were selected and compared with R245fa. The two-stage compression HTHP system model was established. Energy, exergy, environment, and economy analysis with different refrigerants were conducted. R601, R601a, and R1233zd(E) have significant advantages over R245fa when the evaporation temperature is 50°C and condensation temperature is 100∼130°C. When the condensation temperature is 130°C, compared with R245fa, coefficient of performance ( COP ) of R601, R601a and R1233zd(E) increased by 11.08%, 9.14% and 6.14%, respectively. Exergy efficiency increased by 8.71%, 7.24% and 4.77%, respectively. Total equivalent warming impact ( TEWI ) decreased by 10.42%, 8.83% and 6.25%, respectively. Investment payback period ( PBP ) shortened by 69.73%, 65.93% and 40.12%, respectively.