Rasmus Schmidt Davidsen

Dr. Rasmus Schmidt Davidsen

DTU - Technical University of Denmark
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2025 in Energy & Environmental Science
Verified
Journal Article
Open access
PDF file
SKSeán R. Kavanagh
Seán R. Kavanagh
RNRasmus Svejstrup Nielsen
Rasmus Svejstrup Nielsen
JHJohn Lundsgaard Hansen
John Lundsgaard Hansen
RDRasmus Schmidt Davidsen
Rasmus Schmidt Davidsen
OHOle Hansen
Ole Hansen
AWAron Walsh
Aron Walsh
Intrinsic point defects are found to be inactive for electron–hole recombination, while extrinsic impurities do not contribute significantly to doping, pointing to extended defects and interfaces as limiting factors in selenium solar cells.

11 October 2017 in Journal of Applied Physics
Verified
Journal Article
Open access
MPMaksym M. Plakhotnyuk
Maksym M. Plakhotnyuk
MGMaria Gaudig
Maria Gaudig
RDRasmus Schmidt Davidsen
Rasmus Schmidt Davidsen
JLJonas Michael Lindhard
Jonas Michael Lindhard
JHJens Hirsch
Jens Hirsch
OHOle Hansen
Ole Hansen
Black silicon (bSi) is promising for integration into silicon solar cell fabrication flow due to its excellent light trapping and low reflectance, and a continuously improving passivation. However, intensive ion bombardment during the reactive ion etching used to fabricate bSi induces surface damage that causes significant recombination. Here, we present a process optimization strategy for bSi, where surface damage is reduced and surface passivation is improved while excellent light trapping and low reflectance are maintained. We demonstrate that reduction of the capacitively coupled plasma power, during reactive ion etching at non-cryogenic temperature (−20 °C), preserves the reflectivity below 1% and improves the effective minority carrier lifetime due to reduced ion energy. We investigate the effect of the etching process on the surface morphology, light trapping, reflectance, transmittance, and effective lifetime of bSi. Additional surface passivation using atomic layer deposition of Al2O3 significantly improves the effective lifetime. For n-type wafers, the lifetime reaches 12 ms for polished and 7.5 ms for bSi surfaces. For p-type wafers, the lifetime reaches 800 μs for both polished and bSi surfaces.

26 February 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Babak RezaeiBabak Rezaei
Babak Rezaei
SSSaloua Saghir
Saloua Saghir
JPJesper Yue Pan
Jesper Yue Pan
RDRasmus Schmidt Davidsen
Rasmus Schmidt Davidsen
SKStephan Sylvest Keller
Stephan Sylvest Keller
In this article, a novel approach for selective passivation of three-dimensional pyrolytic carbon microelectrodes via a facile electrochemical polymerization of a non-conductive polymer (polydopamine, PDA) onto the surface of carbon electrodes, followed by a selective laser ablation is elaborated. The 3D carbon electrodes consisting of 284 micropillars on a circular 2D carbon base layer were fabricated by pyrolysis of lithographically patterned negative photoresist SU-8. As a second step, dopamine was electropolymerized onto the electrode by cyclic voltammetry (CV) to provide an insulating layer at its surface. The CV parameters, such as the scan rate and the number of cycles, were investigated and optimized to achieve a reliable and uniform non-conductive coating on the surface of the 3D pyrolytic carbon electrode. Finally, the polydopamine was selectively removed only from the tips of the pillars, by using localized laser ablation. The selectively passivated electrodes were characterized by scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectroscopy methods. Due to the surface being composed of highly biocompatible materials, such as pyrolytic carbon and polydopamine, these 3D electrodes are particularly suited for biological application, such as electrochemical monitoring of cells or retinal implants, where highly localized electrical stimulation of nerve cells is beneficial.

20 January 2021 in IEEE Journal of Photovoltaics
Verified
Journal Article
Open access
GSGiuseppe Scardera
Giuseppe Scardera
SWShaozhou Wang
Shaozhou Wang
YZYu Zhang
Yu Zhang
MKMuhammad Umair Khan
Muhammad Umair Khan
SZShuai Zou
Shuai Zou
MAMalcolm D. Abbott
Malcolm D. Abbott
The integration of nanotextured black silicon (B-Si) into solar cells is often complicated by its enhanced phosphorus doping effect, which is typically attributed to increased surface area. In this article, we show that B-Si's surface-to-volume ratio, or specific surface area (SSA), which is directly related to surface reactivity, is a better indicator of reduced sheet resistance. We investigate six B-Si conditions with varying dimensions based on two morphology types prepared using metal-catalyzed chemical etching and reactive-ion etching. We demonstrate that for a POCl 3 diffusion, B-Si sheet resistance decreases with increasing SSA, regardless of surface area. 2-D dopant contrast imaging of different textures with similar surface areas also indicates that the extent of doping is enhanced with increasing SSA. 3-D diffusion simulations of nanocones show that both the extent of radial doping within a texture feature and the metallurgical junction depth in the underlying substrate increase with increasing SSA. We suggest SSA should be considered more readily when studying B-Si and its integration into solar cells.

23 November 2018 in Physica Status Solidi (RRL) – Rapid Research Letters
Verified
Journal Article
Closed access
PDF file
BIBeniamino Iandolo
Beniamino Iandolo
ANAdriana P. Sánchez Nery
Adriana P. Sánchez Nery
RDRasmus Schmidt Davidsen
Rasmus Schmidt Davidsen
OHOle Hansen
Ole Hansen

11 February 2025 in Biomedical Microdevices
Verified
Journal Article
Open access
PDF file
PKPratik Kusumanchi
Pratik Kusumanchi
JMJesper Guldsmed Madsen
Jesper Guldsmed Madsen
TBToke Bek
Toke Bek
SKStephan Sylvest Keller
Stephan Sylvest Keller
RDRasmus Schmidt Davidsen
Rasmus Schmidt Davidsen
Retinal prosthesis has been one of the medical strategies aimed at restoring some degree of vision for patients affected by retinal degenerative diseases, such as Retinitis Pigmentosa (RP) and age-related macular degeneration (AMD), which are leading causes of irreversible visual loss. In retinal prosthesis, electrical pulses are typically delivered to the retinal neurons via electrodes on the surface of the implant. In this work, we fabricated 3D carbon pillar electrodes by pyrolysis of SU-8 structures defined photolithographically on Si wafers. We then measured compound action potentials induced in porcine neuroretinas stimulated with electrical pulses. The recorded spikes were validated to be biological in origin by adding the voltage-gated sodium-channel blocking agent tetrodotoxin. The minimum threshold voltage needed to effectively stimulate retinal cells, such as retinal ganglion cells, with 3D electrodes was analyzed through systematic investigation of the spike rate and amplitudes as a function of stimulation voltage. 3D electrodes significantly increased spike rate and amplitudes above spontaneous activity in the tissue during stimulation and outperformed the 2D counterpart, both in terms of spike rate and amplitude. Our results indicate a threshold voltage range of 500-600 mV for 1 ms pulses at a frequency of 10 Hz above which a significant increase in spike count was observed. Furthermore, we report an order of magnitude increase in peak-to-peak amplitude for evoked spikes (> 3 mV), compared to spontaneous spikes (∼ 200 µV). Based on numerical integration, we estimate the area under the curve to be ~14 times larger in evoked compound action potentials compared to spontaneous activity. This indicates the relative increase in number of contributing cells to the compound action potential. At a stimulation voltage of 600 mV the spike rate for 3D electrodes was above 10 spikes/channel/s. We hypothesize that the significant difference between 2D and 3D electrodes is not only caused by the higher active electrode surface area of the 3D micropillar electrodes, but also by more intricate contact and interaction with the inner cell layers of the retinal tissue. Our findings indicate that 3D carbon micropillar electrodes are promising for electrical stimulation of the retina.