Ahmed Elkoumy

Dr. Ahmed Elkoumy

CORRIB Core Lab University of Galway, Galway, Ireland
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AEAhmed Elkoumy
Ahmed Elkoumy
JJJohn Jose
John Jose
CTchristian juhl terkelsen
christian juhl terkelsen
HNhenrik nissen
henrik nissen
SGSengottuvelu Gunasekaran
Sengottuvelu Gunasekaran
OSOsama Soliman
Osama Soliman
Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI’s procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes.

26 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MAMahmoud Abdelshafy
Mahmoud Abdelshafy
KCKadir Caliskan
Kadir Caliskan
GGGoksel Guven
Goksel Guven
AEAhmed Elkoumy
Ahmed Elkoumy
HEHagar Elsherbini
Hagar Elsherbini
OSOsama Soliman
Osama Soliman
Acute right-sided heart failure (RHF) is a complex clinical syndrome, with a wide range of clinical presentations, associated with increased mortality and morbidity, but about which there is a scarcity of evidence-based literature. A temporary right-ventricular assist device (t-RVAD) is a potential treatment option for selected patients with severe right-ventricular dysfunction as a bridge-to-recovery or as a permanent solution. We sought to conduct a systematic review to determine the safety and efficacy of t-RVAD implantation. Thirty-one studies met the inclusion criteria, from which data were extracted. Successful t-RVAD weaning ranged between 23% and 100%. Moreover, 30-day survival post-temporary RAVD implantation ranged from 46% to 100%. Bleeding, acute kidney injury, stroke, and device malfunction were the most commonly reported complications. Notwithstanding this, t-RVAD is a lifesaving option for patients with severe RHF, but the evidence stems from small non-randomized heterogeneous studies utilizing a variety of devices. Both the etiology of RHF and time of intervention might play a major role in determining the t-RVAD outcome. Standardized endpoints definitions, design and methodology for t-RVAD trials is needed. Furthermore, efforts should continue in improving the technology as well as improving the timely provision of a t-RVAD.

6 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MCMichael Cronin
Michael Cronin
ACAileen Crowley
Aileen Crowley
MDMatthew Davey
Matthew Davey
PRPeter Ryan
Peter Ryan
MAMahmoud Abdelshafy
Mahmoud Abdelshafy
OSOsama Soliman
Osama Soliman
Background: This paper looks to validate the risk score from the Heart Failure Association of the European Society of Cardiology and the International Cardio-Oncology Society (HFA-ICOS) for predicting potential cardiotoxicity from anticancer therapy for patients positive for human epidermal growth factor receptor 2. Methods: A total of 507 patients with at least five years since index diagnosis of breast cancer were retrospectively divided according to the HFA-ICOS risk proforma. According to level of risk, these groups were assessed for rates of cardiotoxicity via mixed-effect Bayesian logistic regression model. Results: A follow-up of five years observed cardiotoxicity of 3.3% (n = 3) in the low-risk, 3.3% (n = 10) in the medium-risk, 4.4% (n = 6) in the high-risk, and 38% (n = 6) in the very-high-risk groups respectively. For cardiac events related to treatment, the risk was significantly higher for the very-high-risk category of HFA-ICOS compared to other categories (Beta = 3.1, 95% CrI: 1.5, 4.8). For overall cardiotoxicity related to treatment, the area under the curve was 0.643 (CI 95%: 0.51, 0.76), with 26.1% (95% CI: 8%, 44%) sensitivity and 97.9% (95% CI: 96%, 99%) specificity. Conclusions: The HFA-ICOS risk score has moderate power in predicting cancer therapy–related cardiotoxicity in HER2-positive breast cancer patients.

5 April 2023 in International Journal of Cardiology
Verified
Journal Article
Open access
AEAhmed Elkoumy
Ahmed Elkoumy
JJJohn Jose
John Jose
SGSengottuvelu Gunasekaran
Sengottuvelu Gunasekaran
AKAsish Kumar
Asish Kumar
BSB.C. Srinivas
B.C. Srinivas
OSOsama Soliman
Osama Soliman
The balloon expandable Myval transcatheter heart valve (THV) showed encouraging results regarding residual aortic regurgitation (AR) from multiple observational studies. The newly designed Myval Octacor has been introduced recently, aiming for a reduction in AR and improved performance. The focus of this study is to report the incidence of AR using the validated quantitative Videodensitometry angiography technology (qLVOT-AR%) in the first in human use of the Myval Octacor THV system. We report on the first in human use of the Myval Octacor THV system in 125 patients in 18 Indian centres. Independent retrospective analysis of the final aortograms following implantation of the Myval Octacor was performed using the CAAS-A-Valve software. AR is reported as a regurgitation fraction. The previously validated cutoff values have been used to identify ≥moderate AR (RF% >17%), mild (6% < RF% ≤17%), and none or trace AR (RF% ≤ 6%). Final aortogram was analysable for 103 patients (84.4%) among the 122 available aortograms. 64 (62%) patients, had tricuspid aortic valve (TAV), 38 (37%) with bicuspid AV (BAV), and one with unicuspid AV. The median absolute RF% was 2% [1, 6], moderate or more AR incidence was 1.9%, mild AR in 20.4%, and none or trace AR in 77.7%. The two cases with RF% >17% were in the BAV group. The initial results of Myval Octacor using quantitative angiography-derived regurgitation fraction demonstrated a favourable outcome regarding residual AR, possibly due to improved device design. Results must be confirmed in a larger randomised study, including other imaging modalities.

9 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ARAndreas Rück
Andreas Rück
WKWon-Keun Kim
Won-Keun Kim
HKHideyuki Kawashima
Hideyuki Kawashima
MAMahmoud Abdelshafy
Mahmoud Abdelshafy
AEAhmed Elkoumy
Ahmed Elkoumy
OSOsama Soliman
Osama Soliman
The new-generation ACURATE neo2 system was commercially released in September 2020. In this study, we sought to compare the aortic regurgitation (AR) severity of the ACURATE neo2 versus the ACURATE neo transcatheter heart valve, using quantitative videodensitometric angiography (qAR). This is a retrospective, Corelab analysis of final post-transcatheter aortic valve implantation (TAVI) aortograms of patients treated with the ACURATE neo2 and ACURATE neo systems. The ACURATE neo2 cohort comprised consecutive patients treated between September 2020 and January 2021 at two centers. The ACURATE neo cohort included consecutive patients treated before September 2020. Our primary objective was to compare AR severity on qAR following TAVI with ACURATE neo2 and ACURATE neo. Out of 401 aortograms, 228 (56.9%) were analyzable, with 120 in the ACURATE neo2 cohort, and 108 in the ACURATE neo cohort. The mean AR fraction was 4.4 ± 4.8% in the neo2 cohort, and 9.9 ± 8.2% in the neo cohort (p < 0.001). Furthermore, moderate or severe AR (qAR > 17%) was detected in 2 aortograms (1.7%) in the neo2 cohort and 15 aortograms (13.9%) in the neo cohort (p < 0.001). Quantitative aortography shows a lower rate of moderate or severe paravalvular AR in what is the first European experience of the new-generation, self-expanding ACURATE neo2 when compared to the first-generation ACURATE neo. Moreover, aortographic data need to be correlated and compared to Core Laboratory-adjudicated 30-day echocardiographic data.

20 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AEAhmed Elkoumy
Ahmed Elkoumy
JJJohn Jose
John Jose
CTchristian juhl terkelsen
christian juhl terkelsen
HNhenrik nissen
henrik nissen
SGSengottuvelu Gunasekaran
Sengottuvelu Gunasekaran
OSOsama Soliman
Osama Soliman
Background: Bicuspid aortic valve (BAV) affects approximately 1.5% of the general population and is seen in nearly 50% of candidates for aortic valve replacement (AVR). Despite increasingly utilised transcatheter aortic valve implantation (TAVI) in aortic stenosis (AS) patients, its use among patients with severe bicuspid AS is limited as BAV is a heterogeneous disease associated with multiple and complex anatomical challenges. Aim: To investigate the one-year outcomes of TAVI using the balloon-expandable Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd., Vapi, India) in patients with severe bicuspid AS. Methods and results: We collected data from consecutive patients with bicuspid AS who underwent TAVI with the Myval THV and had at least one-year follow-up. Baseline characteristics, procedural, and 30-day echocardiographic and clinical outcomes were collected. Sixty-two patients were included in the study. The median age was 72 [66.3, 77.0] years, 45 (72.6%) were males, and the mean STS PROM score was 3.2 ± 2.2%. All TAVI procedures were performed via the transfemoral route. The median follow-up duration was 13.5 [12.2, 18.3] months; all-cause mortality was reported in 7 (11.3%) patients and cardiovascular hospitalisation in 6 (10.6%) patients. All-stroke was reported in 2 (3.2%), permanent pacemaker implantation 5 (8.3%), and myocardial infarction 1 (1.6%) patients. The echocardiographic assessment revealed a mean pressure gradient of 10 [8, 16.5] mmHg, effective orifice area 1.7 [1.4, 1.9] cm2, moderate AR in 1 (2%), mild AR in 14 (27%), and none/trace AR in 37 (71%). In total, 1 patient was diagnosed with valve thrombosis (2.1%), Stage II (moderate) haemodynamic deterioration was seen in 3 (6.4%), and stage III (severe) haemodynamic deterioration in 1 (2.1%) patient. Conclusions: TAVI with the Myval THV in selected BAV anatomy is associated with favourable one-year hemodynamic and clinical outcomes.