Jesper Knutsson

Dr. Jesper Knutsson

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2005 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
BVBranislav Vrana
Branislav Vrana
IAIan J. Allan
Ian J. Allan
RGRichard Greenwood
Richard Greenwood
GMGraham A. Mills
Graham A. Mills
EDEwa Dominiak
Ewa Dominiak
Gregory MorrisonGregory Morrison
Gregory Morrison

1 July 2006 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Closed access
IAIan J. Allan
Ian J. Allan
BVBranislav Vrana
Branislav Vrana
RGRichard Greenwood
Richard Greenwood
GMGraham A. Mills
Graham A. Mills
JKJesper Knutsson
Jesper Knutsson
SLSerena Laschi
Serena Laschi

27 April 2007 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
IAIan J. Allan
Ian J. Allan
JKJesper Knutsson
Jesper Knutsson
NGNathalie Guigues
Nathalie Guigues
GMGraham A. Mills
Graham A. Mills
AFAnne-Marie Fouillac
Anne-Marie Fouillac
RGRichard Greenwood
Richard Greenwood
Passive sampling devices accumulate chemicals continuously from water and can provide time weighted average (TWA) concentrations of pollutants over the exposure period. Hence, they offer a number of advantages over other conventional monitoring techniques such as spot or grab sampling. The diffusive gradient in thin film (DGT) and the Chemcatcher passive samplers can be used to provide TWA concentrations of labile metals, but the approaches to their calibration differ. DGT uses diffusion coefficients of metals in the hydrogel layer, whereas Chemcatcher uses metal specific uptake rates, with both sets of values obtained under controlled laboratory conditions with constant aqueous metal concentrations. However, little is known of how such samplers respond to fluctuating concentrations. We evaluated the responsiveness of these two passive sampling devices to rapidly changing concentrations of Cd, Cu, Ni, Pb and Zn in natural freshwater, over a relatively short deployment time. Maximum metal concentrations in water were varied between 70 and 140 μg L−1. Experiments were carried out in a tank with a rotating carousel system and filled with Meuse river water, allowing a degree of control over experimental conditions while using natural river water. Fluctuating concentrations were obtained by stepwise addition of standard solutions of the metals. The reliability and accuracy of the TWA concentrations measured by the samplers were assessed by comparison with concentrations of the metals in spot samples of water taken regularly over the deployment period. The spot samples of water were either unfiltered (total), filtered (0.45 μm) or ultrafiltered (5 kDa). Predictive speciation modelling using the visual MINTEQ programme was also undertaken. There was reasonable agreement between the TWA concentrations of Cd and Ni obtained with Chemcatcher and DGT and the total Cd and Ni concentrations measured in repeated unfiltered spot samples. For elements (i.e. Cu, Pb, Zn) that associate to a significant degree with suspended solids, colloids or dissolved organic carbon, or form complexes with large organic ligands, optimum agreement was with the filtered or ultrafiltered fractions and with the predicted inorganic and inorganic–fulvic acid associated fractions. While Chemcatcher-based TWA concentration ranges for Cu and Zn were in best agreement with the total filtered fraction, there was lack of agreement for Pb. The combined use of DGT devices with open pore (OP) and restricted pore (RP) gels allowed the labile fraction of metal associated with large organic ligands or DOC to be differentiated and quantified, since this is available to DGT OP but unable to diffuse into the DGT RP. This evaluation of the two sampling devices clearly demonstrated their ability to react reliably to transient peaks in concentration of metal pollutants in water and indicated where future efforts are needed to improve calibration data. Such samplers may prove valuable in responding to the monitoring requirements of the European Union’s Water Framework Directive.

29 April 2005 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
BVBranislav Vrana
Branislav Vrana
GMGraham Mills
Graham Mills
RGRichard Greenwood
Richard Greenwood
JKJesper Knutsson
Jesper Knutsson
KSKatarina Svensson
Katarina Svensson
Gregory MorrisonGregory Morrison
Gregory Morrison
The performance of an integrative passive sampler that consists of a C18 Empore disk sorbent receiving phase fitted with low density polyethylene membrane was optimised for the measurement of time-weighted average concentrations of hydrophobic micropollutants in water. A substantial improvement of sampling characteristics including the rate of sampling and the sampling precision was achieved by decreasing the internal sampler resistance to mass transfer of hydrophobic organic chemicals. This was achieved by adding a small volume of n-octanol, a solvent with high permeability (solubility × diffusivity) for target analytes, to the interstial space between the receiving sorbent phase and the polyethylene diffusion-limiting membrane.

23 May 2008 in Journal of Environmental Monitoring
Verified
Journal Article
Closed access
PDF file
IAIan J. Allan
Ian J. Allan
JKJesper Knutsson
Jesper Knutsson
NGNathalie Guigues
Nathalie Guigues
GMGraham A. Mills
Graham A. Mills
AFAnne-Marie Fouillac
Anne-Marie Fouillac
RGRichard Greenwood
Richard Greenwood
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher® and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7–28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.

1 August 2019 in Applied Energy
Verified
Journal Article
Closed access
PKPavleta Knutsson
Pavleta Knutsson
JMJelena Maric
Jelena Maric
JKJesper Knutsson
Jesper Knutsson
ALAnton Larsson
Anton Larsson
CBClaes Breitholtz
Claes Breitholtz
MSMartin Seemann
Martin Seemann