Wendong Wang

Dr. Wendong Wang

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2022 in Complex & Intelligent Systems
Verified
Journal Article
Open access
PDF file
WWWendong Wang
Wendong Wang
JZJunBo Zhang
JunBo Zhang
XWXin Wang
Xin Wang
XYXiaoQing Yuan
XiaoQing Yuan
PZPeng Zhang
Peng Zhang
The motion intensity of patient is significant for the trajectory control of exoskeleton robot during rehabilitation, as it may have important influence on training effect and human–robot interaction. To design rehabilitation training task according to situation of patients, a novel control method of rehabilitation exoskeleton robot is designed based on motion intensity perception model. The motion signal of robot and the heart rate signal of patient are collected and fused into multi-modal information as the input layer vector of deep learning framework, which is used for the human–robot interaction model of control system. A 6-degree of freedom (DOF) upper limb rehabilitation exoskeleton robot is designed previously to implement the test. The parameters of the model are iteratively optimized by grouping the experimental data, and identification effect of the model is analyzed and compared. The average recognition accuracy of the proposed model can reach up to 99.0% in the training data set and 95.7% in the test data set, respectively. The experimental results show that the proposed motion intensity perception model based on deep neural network (DNN) and the trajectory control method can improve the performance of human–robot interaction, and it is possible to further improve the effect of rehabilitation training.

9 May 2019 in Advanced Robotics
Verified
Journal Article
Closed access
WWWendong Wang
Wendong Wang
LQLei Qin
Lei Qin
XYXiaoqing Yuan
Xiaoqing Yuan
XMXing Ming
Xing Ming
TSTongsen Sun
Tongsen Sun
YLYifan Liu
Yifan Liu
As the complexity of obtaining irregular daily motion trajectory during upper limb rehabilitation training, this paper proposes the bionic control method for the presented exoskeleton robot arm based on motion intention. Firstly, the collected motion signal is pre-processing by filtering. Then the motion intention and motion mode of the processed signal are classified by using the hierarchical multi-classification support vector machine. Meanwhile, the adaptive Hopf oscillator network based on dynamic learning is used for offline learning of joint motion trajectory, and the parameters of the reproduced signal in different motion modes are obtained. Finally, the corresponding parameters are transferred according to the user’s intention, and the oscillator network is reconstructed to realize the periodic motion control of rehabilitation training. With experimental verification, the proposed method can follow the human body’s motion intention and reproduce the daily motion trajectory of the upper limb. The results show it can be used to conduct rehabilitation training for the patient.

1 November 2020 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
PDF file
WWWendong Wang
Wendong Wang
HLHanhao Li
Hanhao Li
DKDezhi Kong
Dezhi Kong
MXMenghan Xiao
Menghan Xiao
PZPeng Zhang
Peng Zhang
The utilization of upper extremity exoskeleton robots has been proved to be a scientifically effective approach for rehabilitation training. In the process of rehabilitation training, it is necessary to detect the fatigue degree during rehabilitation training in order to formulate a reasonable training plan and achieve better training efficiency. Based on the integral value of surface electromyography (sEMG), heart rate variability, and instantaneous heart rate, this article proposes a fatigue judgment method for multi-information fusion. Based on the integral value data, the feature extraction of the bioelectrical signals were implemented separately, then the fatigue recognition was conducted using the decision-level data fusion method. The bioelectrical signal acquisition system of electromyogram signals and electrocardiograph signals was developed for upper limb exoskeleton rehabilitation robot, and the acquisition and processing of electromyogram signals and electrocardiograph signals were completed. Finally, the fuzzy logic controller with instantaneous heart rate, heart rate variability, and surface electromyography signal was designed to judge fatigue degree, including the fuzzy device, fuzzy rule selector, and defuzzifier. The moderate fatigue state data were selected for testing, and the experimental results showed that the error of fatigue judgment is 4.3%, which satisfies the requirements of fatigue judgment.

1 April 2022 in Robotica
Verified
Journal Article
Closed access
PDF file
WWWendong Wang
Wendong Wang
JZJunBo Zhang
JunBo Zhang
DKDezhi Kong
Dezhi Kong
SSShibin Su
Shibin Su
XYXiaoqing Yuan
Xiaoqing Yuan
CZChengzhi Zhao
Chengzhi Zhao
As one of the research hotspots in the field of rehabilitation robotics, the upper limb exoskeleton robot has been widely used in the field of rehabilitation. However, the existing methods cannot comprehensively and accurately reflect the motion state of patients, which may lead to overtraining and secondary injury of patients in the process of rehabilitation training. In this paper, an upper limb exoskeleton control method based on mixed perception model of motion intention and intensity is proposed, which is based on the 6 degree-of-freedom upper limb rehabilitation exoskeleton in the laboratory. First, the kinematic information and heart rate information in the rehabilitation process of patients are collected, corresponding to patients’ motion intention and motion intensity, and fused to obtain the mixed perception vector. Second, the motion perception model based on long short-term memory neural network is established to realize the prediction of upper limb motion trajectory of patients and compared with back-propagation neural network to prove its effectiveness. Finally, the control system is built, and both offline and online test of the control method proposed are implemented. The experimental results show that the method can achieve comprehensive motion state perception of patients, realize real-time and accurate prediction trajectory according to human motion intention and intensity. The average prediction accuracy is 95.3%, and predicted joint angle error is less than 5 degrees. Therefore, the control method based on mixed perception model has good robustness and universality, which provides a new method for the active control of upper limb exoskeleton.

25 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XYXiaoqing Yuan
Xiaoqing Yuan
YLYuxuan Liu
Yuxuan Liu
HZHuan Zou
Huan Zou
JJJunjie Ji
Junjie Ji
TZTong Zhou
Tong Zhou
WWWendong Wang
Wendong Wang
In piezoelectric micropositioning platforms, the displacement amplification mechanism can solve the small output displacement of the platform; the displacement coupling will also increase when the displacement is amplified. To solve the problem of multistage displacement amplification and displacement coupling after multistage displacement amplification, this study proposes a 2-D piezoelectric platform based on three-stage amplification and L-shaped guiding. First, the structure of the 2-D piezoelectric platform is designed and its working principle is described. Next, the 2-D piezoelectric platform is analyzed theoretically, and the static and dynamic characteristics of the structure are analyzed by the finiteelement method. Finally, a prototype of the 2-D piezoelectric platform is fabricated, and the theoretical and simulation results are analyzed experimentally. The experimental results reveal that the platform has a motion range of $31.8\times41\,\,\mu \text{m}$ . The multistage displacement amplification ratio is 21.8, and the displacement coupling error is less than 4.2%. The positioning error of the closed-loop control platform is less than 0.5%, and the trajectory tracking error is less than 1.6%. Compared with the traditional piezoelectric micropositioning platform, the three-stage amplification and L-shaped guiding mechanism can effectively improve the displacement magnification and decoupling performance of the piezoelectric micropositioning platform as well as the positioning ability and trajectory tracking ability of the platform under closed-loop control, which is expected to be utilized in fields such as multistage amplification micropositioning platforms and dynamic optical systems.

1 July 2018 in International Journal of Advanced Robotic Systems
Verified
Journal Article
Open access
PDF file
WWWendong Wang
Wendong Wang
PZPeng Zhang
Peng Zhang
CLChaohong Liang
Chaohong Liang
YSYikai Shi
Yikai Shi
A massage robot that helps to improve the quality of human life has attracted more interests of researchers and consumers. A portable back massage robot that is compact and space-saving was designed to be used on human back instead of a traditional large-scale structure robot. To design the massage robot, the models of electric circuit, magnetic circuit and mechanics were analyzed to achieve optimal massage force. Parameters of the massage actuator are determined based on the influence analysis of the coil current, the coil turns and the distance between the moving core and the yoke on the electromagnetic force. The massage coverage of human back, which is used to calculate the massage effect, could be improved by an excellent path planning algorithm. This article proposed an efficient full covered path planning algorithm for the designed massage robot, and the relevant algorithm models were established. Simulation results show that the coil current is much more sensitive to electromagnetic force of the moving core compared to the other two factors, and the presented path planning algorithm completes full coverage of the massage robot on the back area. The experimental platform of the massage robot was built, and the influence of the input signal duty cycle, the input signal voltage and the hardness of the massage object on the massage effect was discussed by testing the values of acceleration. The tested results show that the massage effect is best when the duty cycle is in the range of 1/8–1/2. Meanwhile, the hardness of massage parts affects the massage intensity. The consistency between the tested results of path planning and simulation verifies the feasibility of the simulation procedure and indicates that the massage robot can attain the desired massage performance and realize the planned paths.