Xiaoqing Yuan

Prof. Dr. Xiaoqing Yuan

Northwestern Polytechnical University, Xi'an, China
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
WWWendong Wang
Wendong Wang
YSYikai Shi
Yikai Shi
NYNing Yang
Ning Yang
XYXiaoqing Yuan
Xiaoqing Yuan
Bone drilling is an essential part in orthopaedics, traumatology and bone biopsy. Prediction and control of drilling forces and torque are critical to the success of operations involving bone drilling. This paper studied the drilling force, torque and drilling process with automatic and manual drill penetrating into bovine cortical bone. The tests were performed on a drilling system which is used to drill and measure forces and torque during drilling. The effects of drilling speed, feed rate and drill bit diameter on force and torque were discussed separately. The experimental results were proven to be in accordance with the mathematic expressions introduced in this paper. The automatic drilling saved drilling time by 30-60% in the tested range and created less vibration, compared to manual drilling. The deviation between maximum and average force of the automatic drilling was 5N but 25N for manual drilling. To conclude, using the automatic method has significant advantages in control drilling force, torque and drilling process in bone drilling.

20 March 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
WWWang Wendong
Wang Wendong
LHLi Hanhao
Li Hanhao
XMXiao Menghan
Xiao Menghan
CYChu Yang
Chu Yang
XYXiaoqing Yuan
Xiaoqing Yuan
ZBZhang Bing
Zhang Bing
This paper presents the design of a motion intent recognition system, based on an altitude signal sensor, to improve the human-robot interaction performance of upper limb exoskeleton robots during rehabilitation training. A modified adaptive Kalman filter combined with clipping filtering is proposed for the control system to mitigate the noise and time delay of the collected signal. The clipping filtering method was used to filter the accidental error and avoid the safety problem caused by a mistrigger. A modified adaptive Kalman filter was used to account for the sudden change of the motion state during rehabilitation training. The results show that the intent recognition system designed herein can accurately recognize the human-robot interaction information, and estimate the intent of human motion in time. Therefore, it can be concluded that the designed system effectively follows the predicted motion intent with the proposed method, which is a significant improvement for human-robot interaction control of upper limb extremity rehabilitation robots.

21 December 2007 in Optics & Laser Technology
Verified
Journal Article
Closed access
JZJiang-Hai Zhao
Jiang-Hai Zhao
YSYi-Kai Shi
Yi-Kai Shi
NSNing Shan
Ning Shan
XYXiaoqing Yuan
Xiaoqing Yuan

9 May 2019 in Advanced Robotics
Verified
Journal Article
Closed access
WWWendong Wang
Wendong Wang
LQLei Qin
Lei Qin
XYXiaoqing Yuan
Xiaoqing Yuan
XMXing Ming
Xing Ming
TSTongsen Sun
Tongsen Sun
YLYifan Liu
Yifan Liu
As the complexity of obtaining irregular daily motion trajectory during upper limb rehabilitation training, this paper proposes the bionic control method for the presented exoskeleton robot arm based on motion intention. Firstly, the collected motion signal is pre-processing by filtering. Then the motion intention and motion mode of the processed signal are classified by using the hierarchical multi-classification support vector machine. Meanwhile, the adaptive Hopf oscillator network based on dynamic learning is used for offline learning of joint motion trajectory, and the parameters of the reproduced signal in different motion modes are obtained. Finally, the corresponding parameters are transferred according to the user’s intention, and the oscillator network is reconstructed to realize the periodic motion control of rehabilitation training. With experimental verification, the proposed method can follow the human body’s motion intention and reproduce the daily motion trajectory of the upper limb. The results show it can be used to conduct rehabilitation training for the patient.

1 April 2022 in Robotica
Verified
Journal Article
Closed access
PDF file
WWWendong Wang
Wendong Wang
JZJunBo Zhang
JunBo Zhang
DKDezhi Kong
Dezhi Kong
SSShibin Su
Shibin Su
XYXiaoqing Yuan
Xiaoqing Yuan
CZChengzhi Zhao
Chengzhi Zhao
As one of the research hotspots in the field of rehabilitation robotics, the upper limb exoskeleton robot has been widely used in the field of rehabilitation. However, the existing methods cannot comprehensively and accurately reflect the motion state of patients, which may lead to overtraining and secondary injury of patients in the process of rehabilitation training. In this paper, an upper limb exoskeleton control method based on mixed perception model of motion intention and intensity is proposed, which is based on the 6 degree-of-freedom upper limb rehabilitation exoskeleton in the laboratory. First, the kinematic information and heart rate information in the rehabilitation process of patients are collected, corresponding to patients’ motion intention and motion intensity, and fused to obtain the mixed perception vector. Second, the motion perception model based on long short-term memory neural network is established to realize the prediction of upper limb motion trajectory of patients and compared with back-propagation neural network to prove its effectiveness. Finally, the control system is built, and both offline and online test of the control method proposed are implemented. The experimental results show that the method can achieve comprehensive motion state perception of patients, realize real-time and accurate prediction trajectory according to human motion intention and intensity. The average prediction accuracy is 95.3%, and predicted joint angle error is less than 5 degrees. Therefore, the control method based on mixed perception model has good robustness and universality, which provides a new method for the active control of upper limb exoskeleton.

22 May 2019 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
PDF file
NANaqash Azeem
Naqash Azeem
XYXiaoqing Yuan
Xiaoqing Yuan
HRHassan Raza
Hassan Raza
IUIqra Urooj
Iqra Urooj
Traditional industry is shifting towards the ‘industry 4.0 factory’ that incorporates automatic fault detection and correction. Industry 4.0 also includes online condition monitoring to make maintenance decisions on the basis of the health of a single machine. This research article presents order analysis for detecting two common problems in rotating machinery – misalignment and cracks. The systematic and detailed experimentations were performed on SpectraQuest’s Machinery Fault Simulator™, and the time domain data acquired through the accelerometers mounted on motor and rotor inboard and outboard bearing housing were transformed into spectra using a fast Fourier transform. Two sets of experiments have been performed for misalignment and one set for shaft cracks. Three levels of misalignment with two types of loading conditions have been analysed. The faulty vibration data were compared with the healthy shaft. The misaligned shaft shows higher vibration amplitude at 2× running speed and harmonic vibration behaviour. The slit repair and V-notch crack shaft models were used to analyse the effect of cracks on vibrations and the resulting vibration spectra showed peaks at 2× and 3× running speed. These results indicate that order analysis is helpful in detecting misaligned and cracked shafts, supporting industry 4.0 by facilitating the automatic detection of faults.