Guannan Li

Dr. Guannan Li

School of Urban Construction, Wuhan University of Science and Technology, Wuhan 430065, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
LWLuhan Wang
Luhan Wang
Guannan LiGuannan Li
Guannan Li
JGJiajia Gao
Jiajia Gao
XFXi Fang
Xi Fang
CWChongchong Wang
Chongchong Wang
CXChenglong Xiong
Chenglong Xiong
Due to energy constraints and people’s increasing requirements for indoor thermal comfort, improving energy efficiency while ensuring thermal comfort has become the focus of research in the design and operation of HVAC systems. This study took office rooms with few people occupying them in Wuhan as the research object. The EnergyPlus-Fluent co-simulation method was used to study the impact of 12 forms of air distribution on the thermal environment and air-conditioner energy consumption. The results indicate that 3 m/s supply air velocity and 45° supply air angle are more suitable for the case model in this study. The EnergyPlus-Fluent co-simulation method used in this paper provides a reference for the study of indoor environments in offices with few people occupying them.

22 January 2022 in Building Simulation
Verified
Journal Article
Closed access
PDF file
JLJiangyan Liu
Jiangyan Liu
XLXin Li
Xin Li
Guannan LiGuannan Li
Guannan Li
CWChuang Wu
Chuang Wu
DLDingChao Li
DingChao Li
JZJinjiang Zhang
Jinjiang Zhang

18 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Guannan LiGuannan Li
Guannan Li
HHHaonan Hu
Haonan Hu
JGJiajia Gao
Jiajia Gao
XFXi Fang
Xi Fang
Sensor drift fault calibration is essential to maintain the operation of heating, ventilation and air conditioning systems (HVAC) in buildings. Bayesian inference (BI) is becoming more and more popular as a commonly used sensor fault calibration method. However, this method focused mainly on sensor bias fault, and it could be difficult to calibrate drift fault that changes with time. Therefore, a dynamic calibration method for sensor drift fault of HVAC systems based on BI is developed. Taking the drift fault calibration of the chilled water supply temperature sensor of the chiller as an example, the performance of the proposed dynamic calibration method is evaluated. Results show that the combination of the Exponentially Weighted Moving-Average (EWMA) method with high detection accuracy and the proposed BI dynamic calibration method can effectively improve the calibration accuracy of drift fault, and the Mean Absolute Percentage Error (MAPE) value between the calibrated and normal data is less than 5%.

19 August 2024 in Building Simulation
Verified
Journal Article
Closed access
PDF file
CXChenglong Xiong
Chenglong Xiong
Guannan LiGuannan Li
Guannan Li
YYYing Yan
Ying Yan
HZHanyuan Zhang
Hanyuan Zhang
CXChengliang Xu
Chengliang Xu
LCLiang Chen
Liang Chen

9 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Guannan LiGuannan Li
Guannan Li
YWYong Wang
Yong Wang
CZChunzhi Zhang
Chunzhi Zhang
XCXu Ch
Xu Ch
ZLZhan Lei
Zhan Lei
Weather data errors affect energy management by influencing the accuracy of building energy predictions. This study presents a long short-term memory (LSTM) prediction model based on the “Energy Detective” dataset (Shanghai, China) and neighboring weather station data. The study analyzes the errors of different weather data sources (Detective and A) at the same latitude and longitude. Subsequently, it discusses the effects of weather errors from neighboring weather stations (Detective, A, B, C, and D) on energy forecasts for the next hour and day including the selection process for neighboring weather stations. Furthermore, it compares the forecast results for summer and autumn. The findings indicate a correlation between weather errors from neighboring weather stations and energy consumption. The median R-Square for predicting the next hour reached 0.95. The model’s predictions for the next day exhibit a higher Prediction Interval Mean Width (139.0 in summer and 146.1 in autumn), indicating a greater uncertainty.

9 February 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Guannan LiGuannan Li
Guannan Li
CWChongchong Wang
Chongchong Wang
LLLamei Liu
Lamei Liu
XFXi Fang
Xi Fang
WKWei Kuang
Wei Kuang
CXChenglong Xiong
Chenglong Xiong
A lack of available information on heating, ventilation, and air-conditioning (HVAC) systems can affect the performance of data-driven fault-tolerant control (FTC) models. This study proposed an in situ selective incremental calibration (ISIC) strategy. Faults were introduced into the indoor air (Ttz1) thermostat and supply air temperature (Tsa) and chilled water supply air temperature (Tchws) sensors of a central air-conditioning system. The changes in the system performance after FTC were evaluated. Then, we considered the effects of the data quality, data volume, and variable number on the FTC results. For the Ttz1 thermostat and Tsa sensor, the system energy consumption was reduced by 2.98% and 3.72% with ISIC, respectively, and the predicted percentage dissatisfaction was reduced by 0.67% and 0.63%, respectively. Better FTC results were obtained using ISIC when the Ttz1 thermostat had low noise, a 7-day data volume, or sufficient variables and when the Tsa and Tchws sensors had low noise, a 14-day data volume, or limited variables.