Due to energy constraints and people’s increasing requirements for indoor thermal comfort, improving energy efficiency while ensuring thermal comfort has become the focus of research in the design and operation of HVAC systems. This study took office rooms with few people occupying them in Wuhan as the research object. The EnergyPlus-Fluent co-simulation method was used to study the impact of 12 forms of air distribution on the thermal environment and air-conditioner energy consumption. The results indicate that 3 m/s supply air velocity and 45° supply air angle are more suitable for the case model in this study. The EnergyPlus-Fluent co-simulation method used in this paper provides a reference for the study of indoor environments in offices with few people occupying them.
Sensor drift fault calibration is essential to maintain the operation of heating, ventilation and air conditioning systems (HVAC) in buildings. Bayesian inference (BI) is becoming more and more popular as a commonly used sensor fault calibration method. However, this method focused mainly on sensor bias fault, and it could be difficult to calibrate drift fault that changes with time. Therefore, a dynamic calibration method for sensor drift fault of HVAC systems based on BI is developed. Taking the drift fault calibration of the chilled water supply temperature sensor of the chiller as an example, the performance of the proposed dynamic calibration method is evaluated. Results show that the combination of the Exponentially Weighted Moving-Average (EWMA) method with high detection accuracy and the proposed BI dynamic calibration method can effectively improve the calibration accuracy of drift fault, and the Mean Absolute Percentage Error (MAPE) value between the calibrated and normal data is less than 5%.
Weather data errors affect energy management by influencing the accuracy of building energy predictions. This study presents a long short-term memory (LSTM) prediction model based on the “Energy Detective” dataset (Shanghai, China) and neighboring weather station data. The study analyzes the errors of different weather data sources (Detective and A) at the same latitude and longitude. Subsequently, it discusses the effects of weather errors from neighboring weather stations (Detective, A, B, C, and D) on energy forecasts for the next hour and day including the selection process for neighboring weather stations. Furthermore, it compares the forecast results for summer and autumn. The findings indicate a correlation between weather errors from neighboring weather stations and energy consumption. The median R-Square for predicting the next hour reached 0.95. The model’s predictions for the next day exhibit a higher Prediction Interval Mean Width (139.0 in summer and 146.1 in autumn), indicating a greater uncertainty.
A lack of available information on heating, ventilation, and air-conditioning (HVAC) systems can affect the performance of data-driven fault-tolerant control (FTC) models. This study proposed an in situ selective incremental calibration (ISIC) strategy. Faults were introduced into the indoor air () thermostat and supply air temperature () and chilled water supply air temperature () sensors of a central air-conditioning system. The changes in the system performance after FTC were evaluated. Then, we considered the effects of the data quality, data volume, and variable number on the FTC results. For the thermostat and sensor, the system energy consumption was reduced by 2.98% and 3.72% with ISIC, respectively, and the predicted percentage dissatisfaction was reduced by 0.67% and 0.63%, respectively. Better FTC results were obtained using ISIC when the thermostat had low noise, a 7-day data volume, or sufficient variables and when the and sensors had low noise, a 14-day data volume, or limited variables.