Due to energy constraints and people’s increasing requirements for indoor thermal comfort, improving energy efficiency while ensuring thermal comfort has become the focus of research in the design and operation of HVAC systems. This study took office rooms with few people occupying them in Wuhan as the research object. The EnergyPlus-Fluent co-simulation method was used to study the impact of 12 forms of air distribution on the thermal environment and air-conditioner energy consumption. The results indicate that 3 m/s supply air velocity and 45° supply air angle are more suitable for the case model in this study. The EnergyPlus-Fluent co-simulation method used in this paper provides a reference for the study of indoor environments in offices with few people occupying them.
Sensor drift fault calibration is essential to maintain the operation of heating, ventilation and air conditioning systems (HVAC) in buildings. Bayesian inference (BI) is becoming more and more popular as a commonly used sensor fault calibration method. However, this method focused mainly on sensor bias fault, and it could be difficult to calibrate drift fault that changes with time. Therefore, a dynamic calibration method for sensor drift fault of HVAC systems based on BI is developed. Taking the drift fault calibration of the chilled water supply temperature sensor of the chiller as an example, the performance of the proposed dynamic calibration method is evaluated. Results show that the combination of the Exponentially Weighted Moving-Average (EWMA) method with high detection accuracy and the proposed BI dynamic calibration method can effectively improve the calibration accuracy of drift fault, and the Mean Absolute Percentage Error (MAPE) value between the calibrated and normal data is less than 5%.
Energy-saving renovations of existing central air-conditioning systems have increasingly received recognition. Theoretical energy consumption model (TECM) is commonly used to estimate the baseline energy consumption of water pumps for comprehensive benefit assessments. Nevertheless, the calculated results often exhibit significant discrepancies compared to the actual values. This study proposes a novel enhanced theoretical energy consumption model (EN-TECM) for improving the calculation accuracy of pump energy consumption, focusing on two dimensions: the number and frequency of operating pumps. Then, 576 sets of pump operation data from 29 actual central air-conditioning systems are used as samples to determine the model key parameter. Further, three actual engineering cases are employed to evaluate the application performance of the EN-TECM. The model regression results show a significant reduction in calculation errors across all operating conditions, with the mean relative errors within ±1%. The analysis results of all engineering cases demonstrate that the relative errors of the cumulative total energy consumption decrease by more than 60% compared to the TECM. This research offers a practical and effective method for accurately calculating the energy consumption of chilled water pumps in field-operated central air-conditioning water systems, which will facilitate the advancement of energy-saving retrofitting projects for existing buildings.
Radiative sky cooling can be effectively integrated with pipe-embedded wall systems to reduce building cooling loads. However, the energy-saving and carbon reduction potential of this technology varies according to climatic conditions and the method of integration, requiring quantification. To address this gap, a revised degree-hour method of evaluating energy efficiency for an integrated system is proposed and validated, and a global potential map is developed. The proposed method can be used to predict the energy-saving and carbon reduction potential of radiative sky coolers under different climatic conditions. Compared to physical model prediction methods, the revised degree-hour method is faster and more accurate, with an evaluation error of approximately 5%. The results indicate that the integrated system performs well in most regions with cooling demand. The system’s energy-saving potential is highest in cities in tropical savanna and desert climate zones, achieving energy savings of approximately 53.96 kWh/m2 and reducing carbon emissions by approximately 22.99 kgCO2/m2 during the cooling season. Its performance is reduced in subtropical monsoon zones, with savings of 8.36 kWh/m2 and 3.56 kgCO2/m2. Furthermore, the system’s energy-saving potential generally declines as the cold-water temperature of the radiative sky cooler increases, especially in tropical regions. This work provides a rapid assessment tool and global reference data to support low-energy building design.