Mueez Aizaz

Mr. Mueez Aizaz

Maastricht University, Maastricht, Limburg, The Netherlands
+2
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Cardiovascular Diagnosis and Therapy
Verified
Journal Article
Open access
PDF file
MAMueez Aizaz
Mueez Aizaz
RMRik P. M. Moonen
Rik P. M. Moonen
JPJochem A. J. van der Pol
Jochem A. J. van der Pol
CPClaudia Prieto
Claudia Prieto
RBRene Botnar
Rene Botnar
MKM. Eline Kooi
M. Eline Kooi
Myocardial infarction and stroke are the most prevalent global causes of death. Each year 15 million people worldwide die due to myocardial infarction or stroke. Rupture of a vulnerable atherosclerotic plaque is the main underlying cause of stroke and myocardial infarction. Key features of a vulnerable plaque are inflammation, a large lipid-rich necrotic core (LRNC) with a thin or ruptured overlying fibrous cap, and intraplaque hemorrhage (IPH). Noninvasive imaging of these features could have a role in risk stratification of myocardial infarction and stroke and can potentially be utilized for treatment guidance and monitoring. The recent development of hybrid PET/MRI combining the superior soft tissue contrast of MRI with the opportunity to visualize specific plaque features using various radioactive tracers, paves the way for comprehensive plaque imaging. In this review, the use of hybrid PET/MRI for atherosclerotic plaque imaging in carotid and coronary arteries is discussed. The pros and cons of different hybrid PET/MRI systems are reviewed. The challenges in the development of PET/MRI and potential solutions are described. An overview of PET and MRI acquisition techniques for imaging of atherosclerosis including motion correction is provided, followed by a summary of vessel wall imaging PET/MRI studies in patients with carotid and coronary artery disease. Finally, the future of imaging of atherosclerosis with PET/MRI is discussed.

4 February 2022 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
GCG.A.J.C. Crombag
G.A.J.C. Crombag
MAMueez Aizaz
Mueez Aizaz
FSF.H.B.M. Schreuder
F.H.B.M. Schreuder
FBF. Benali
F. Benali
DDDianne H.K. van Dam-Nolen
Dianne H.K. van Dam-Nolen
MKM. Eline Kooi
M. Eline Kooi
BACKGROUND AND PURPOSE: Intraplaque hemorrhage contributes to lipid core enlargement and plaque progression, leading to plaque destabilization and stroke. The mechanisms that contribute to the development of intraplaque hemorrhage are not completely understood. A higher incidence of intraplaque hemorrhage and thin/ruptured fibrous cap (upstream of the maximum stenosis in patients with severe [≥70%] carotid stenosis) has been reported. We aimed to noninvasively study the distribution of intraplaque hemorrhage and a thin/ruptured fibrous cap in patients with mild-to-moderate carotid stenosis. MATERIALS AND METHODS: Eighty-eight symptomatic patients with stroke (<70% carotid stenosis included in the Plaque at Risk study) demonstrated intraplaque hemorrhage on MR imaging in the carotid artery plaque ipsilateral to the side of TIA/stroke. The intraplaque hemorrhage area percentage was calculated. A thin/ruptured fibrous cap was scored by comparing pre- and postcontrast black-blood TSE images. Differences in mean intraplaque hemorrhage percentages between the proximal and distal regions were compared using a paired-samples t test. The McNemar test was used to reveal differences in proportions of a thin/ruptured fibrous cap. RESULTS: We found significantly larger areas of intraplaque hemorrhage in the proximal part of the plaque at 2, 4, and 6 mm from the maximal luminal narrowing, respectively: 14.4% versus 9.6% (P = .04), 14.7% versus 5.4% (P < .001), and 11.1% versus 2.2% (P = .001). Additionally, we found an increased proximal prevalence of a thin/ruptured fibrous cap on MR imaging at 2, 4, 6, and 8 mm from the MR imaging section with the maximal luminal narrowing, respectively: 33.7% versus 18.1%, P = .007; 36.1% versus 7.2%, P < .001; 33.7% versus 2.4%, P = .001; and 30.1% versus 3.6%, P = .022. CONCLUSIONS: We demonstrated that intraplaque hemorrhage and a thin/ruptured fibrous cap are more prevalent on the proximal side of the plaque compared with the distal side in patients with mild-to-moderate carotid stenosis.

Verified
Journal Article
Open access
PDF file
MAMueez Aizaz
Mueez Aizaz
JPJochem van der Pol
Jochem van der Pol
RWRoel Wierts
Roel Wierts
HZHans Zwart
Hans Zwart
AWAbe J. van der Werf
Abe J. van der Werf
MKM. Eline Kooi
M. Eline Kooi
Carotid radiofrequency coils inside a PET/MRI system can result in PET quantification errors. We compared the performance of a dedicated PET/MRI carotid coil against a coil for MRI-only use. An 18F-fluorodeoxyglucose (18F-FDG) phantom was scanned without and with an MRI-only coil and with the PET/MRI coil. The decay-corrected normalized activity was compared for the different coil configurations. Eighteen patients were scanned with the three coil configurations. The maximal standardized uptake values (SUVmax) and signal-to-noise ratios (SNR) were calculated. Repeated measures ANOVA was performed to assess the differences in SUVmax and SNR between the coil configurations. In the phantom study, the PET/MRI coil demonstrated a slight decrease (<5%), while the MRI-only coil showed a substantial decrease (up to 10%) in normalized activity at the position of coil elements compared to no dedicated coil configuration. In the patient study, the SUVmax values for both no surface coil (3.59 ± 0.15) and PET/MRI coil (3.54 ± 0.15) were significantly higher (p = 0.03 and p = 0.04, respectively) as compared to the MRI-only coil (3.28 ± 0.16). No significant difference was observed between PET/MRI and no surface coil (p = 1.0). The SNR values for both PET/MRI (7.31 ± 0.44) and MRI-only (7.62 ± 0.42) configurations demonstrated significantly higher (p < 0.001) SNR values as compared to the no surface coil (3.78 ± 0.22), while no significant difference was observed in SNR between the PET/MRI and MRI-only coil (p = 1.0). This study demonstrated that the PET/MRI coil can be used for PET imaging without requiring attenuation correction while acquiring high-resolution MR images.


9 December 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
JPJochem van der Pol
Jochem van der Pol
BRBraim Rahel
Braim Rahel
YCYvonne van Cauteren
Yvonne van Cauteren
RMRik P. M. Moonen
Rik P. M. Moonen
JMJoan G. Meeder
Joan G. Meeder
MKM. Eline Kooi
M. Eline Kooi
Background/Objectives: 18F-fluorocholine is a positron emission tomography (PET) tracer earlier found to be a marker of macrophage content in carotid plaques. We aimed to assess the feasibility of 18F-choline PET-MRI to non-invasively localize vulnerable coronary plaques, using optical coherence tomography (OCT) as a reference standard. Methods: Patients with recent myocardial infarction who were scheduled for a secondary angiography of a non-culprit vessel underwent 18F-fluorocholine coronary PET-MRI. Subsequently, OCT was performed during the secondary angiography. Maximum target-to-background (TBRmax) values of 18F-fluorocholine uptake were determined in two vessel sections that contained either vulnerable or stable plaques as defined by OCT. The OCT-based definition of a vulnerable plaque was a fibrous cap thickness < 70 µm. To enhance the detectability of coronary plaques using PET, three different motion-correction strategies were used: multigate respiratory gating motion correction (MRG-MOCO), extended MR-based motion correction (eMR-MOCO), and extended MR-based motion correction with ECG gating (eMR-MOCO-ECG). Results: Fifteen patients were included in this study. One patient needed to be excluded due to extravasation of the tracer. In another patient, no region with only a stable plaque could be identified. TBRmax values were as follows for three different reconstructions in vulnerable versus stable plaques: MRG-MOCO: mean TBRmax 1.45 vs. 1.35, p = 0.52 (n = 13); eMR-MOCO: mean TBRmax 1.47 vs. 1.27, p = 0.26 (n = 11); eMR-MOCO-ECG: mean TBRmax 1.49 vs. 1.26, p = 0.21 (n = 11). Conclusions: 18F-fluorocholine uptake in vulnerable atherosclerotic plaques in coronary arteries was not significantly different from uptake in stable plaques, even though advanced motion-correction methods were applied. That may be caused by multiple factors, such as small coronary plaque size, tracer biology, or remaining cardiac motion.