Jochem van der Pol

Mr. Jochem van der Pol

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
TWTineke van de Weijer
Tineke van de Weijer
MBMartijn P. G. Broen
Martijn P. G. Broen
RMRik P. M. Moonen
Rik P. M. Moonen
AHAnn Hoeben
Ann Hoeben
MAMonique Anten
Monique Anten
APAlida Annechien Postma
Alida Annechien Postma
Gliomas are the most frequent primary tumors of the brain. They can be divided into grade II-IV astrocytomas and grade II-III oligodendrogliomas, based on their histomolecular profile. The prognosis and treatment is highly dependent on grade and well-identified prognostic and/or predictive molecular markers. Multi-parametric MRI, including diffusion weighted imaging, perfusion, and MR spectroscopy, showed increasing value in the non-invasive characterization of specific molecular subsets of gliomas. Radiolabeled amino-acid analogues, such as 18F-FET, have also been proven valuable in glioma imaging. These tracers not only contribute in the diagnostic process by detecting areas of dedifferentiation in diffuse gliomas, but this technique is also valuable in the follow-up of gliomas, as it can differentiate pseudo-progression from real tumor progression. Since multi-parametric MRI and 18F-FET PET are complementary imaging techniques, there may be a synergistic role for PET-MRI imaging in the neuro-oncological imaging of primary brain tumors. This could be of value for both primary staging, as well as during treatment and follow-up.

26 February 2024 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Open access
PDF file
TWTineke van de Weijer
Tineke van de Weijer
FBF. Bemer
F. Bemer
JVJudith De Vos-Geelen
Judith De Vos-Geelen
BHB. Hermans
B. Hermans
CMCristina Mitea
Cristina Mitea
FMFelix M. Mottaghy
Felix M. Mottaghy
Purpose: The need for an interval between the administration of long-acting Somatostatin Receptor Analogues (SSA) and the [68Ga]Ga-DOTA-TATE PET has been questioned based on recent literature in the new EANM guidelines. Here an earlier studies showed that SSA injection immediately before SSTR PET had minimal effect on normal organ and tumor uptake (1). However, data are scarce and there are (small) differences between [68Ga]Ga-DOTA-TATE and [68Ga]Ga-DOTA-TOC binding affinity, and it remains unknown whether these findings can be directly translated to scans with [68Ga]Ga-DOTA-TOC as well. The purpose of this study was to assess the effect of SSA use on the biodistribution in a subsequent [68Ga]Ga-DOTA-TOC PET/CT and compare this intra-individually across several cycles of SSA treatments. Methods: Retrospectively, 35 patients with NENs were included. [68Ga]Ga-DOTA-TOC PET at staging and after the 1st and 2nd cycle of SSA were included. SUVmean and SUVmax of blood, visceral organs, primary tumor and two metastases were determined. Also, the interval between SSA therapy and the PET scan was registered. Results: Treatment with SSA resulted in a significantly higher bloodpool activity and lower visceral tracer uptake. This effect was maintained after a 2nd cycle of SSA therapy. Furthermore, there was an inverse relationship between bloodpool tracer availability and visceral tracer binding and a positive correlation between bloodpool tracer availability and primary tumor tracer uptake. With an interval of up to 5 days, there was a significantly higher bloodpool activity than at longer intervals. Conclusion: Absolute comparison of the SUV on [68Ga]Ga-DOTA-TOC PET should be done with caution as the altered biodistribution of the tracer after SSA treatment should be taken into account. We recommend not to perform a scan within the first 5 days after the injection of lanreotide.

Verified
Journal Article
Open access
PDF file
MAMueez Aizaz
Mueez Aizaz
JPJochem van der Pol
Jochem van der Pol
RWRoel Wierts
Roel Wierts
HZHans Zwart
Hans Zwart
AWAbe J. van der Werf
Abe J. van der Werf
MKM. Eline Kooi
M. Eline Kooi
Carotid radiofrequency coils inside a PET/MRI system can result in PET quantification errors. We compared the performance of a dedicated PET/MRI carotid coil against a coil for MRI-only use. An 18F-fluorodeoxyglucose (18F-FDG) phantom was scanned without and with an MRI-only coil and with the PET/MRI coil. The decay-corrected normalized activity was compared for the different coil configurations. Eighteen patients were scanned with the three coil configurations. The maximal standardized uptake values (SUVmax) and signal-to-noise ratios (SNR) were calculated. Repeated measures ANOVA was performed to assess the differences in SUVmax and SNR between the coil configurations. In the phantom study, the PET/MRI coil demonstrated a slight decrease (<5%), while the MRI-only coil showed a substantial decrease (up to 10%) in normalized activity at the position of coil elements compared to no dedicated coil configuration. In the patient study, the SUVmax values for both no surface coil (3.59 ± 0.15) and PET/MRI coil (3.54 ± 0.15) were significantly higher (p = 0.03 and p = 0.04, respectively) as compared to the MRI-only coil (3.28 ± 0.16). No significant difference was observed between PET/MRI and no surface coil (p = 1.0). The SNR values for both PET/MRI (7.31 ± 0.44) and MRI-only (7.62 ± 0.42) configurations demonstrated significantly higher (p < 0.001) SNR values as compared to the no surface coil (3.78 ± 0.22), while no significant difference was observed in SNR between the PET/MRI and MRI-only coil (p = 1.0). This study demonstrated that the PET/MRI coil can be used for PET imaging without requiring attenuation correction while acquiring high-resolution MR images.

27 November 2019 in EJNMMI Research
Verified
Journal Article
Open access
PDF file
EBEllen Boswijk
Ellen Boswijk
RFRenee Franssen
Renee Franssen
GVGuy Vijgen
Guy Vijgen
RWRoel Wierts
Roel Wierts
JPJochem van der Pol
Jochem van der Pol
JBJan Bucerius
Jan Bucerius
Background: Vagus nerve activation impacts inflammation. Therefore, we hypothesized that vagal nerve stimulation (VNS) influenced arterial wall inflammation as measured by 18F-FDG uptake. Results: Ten patients with left-sided VNS for refractory epilepsy were studied during stimulation (VNS-on) and in the hours after stimulation was switched off (VNS-off). In nine patients, 18F-FDG uptake was measured in the right carotid artery, aorta, bone marrow, spleen, and adipose tissue. Target-to-background ratios (TBRs) were calculated to normalize the respective standardized uptake values (SUVs) for venous blood pool activity. Median values are shown with interquartile range and compared using the Wilcoxon signed-rank test. Arterial SUVs tended to be higher during VNS-off than VNS-on [SUVmax all vessels 1.8 (1.5–2.2) vs. 1.7 (1.2–2.0), p = 0.051]. However, a larger difference was found for the venous blood pool at this time point, reaching statistical significance in the vena cava superior [meanSUVmean 1.3 (1.1–1.4) vs. 1.0 (0.8–1.1); p = 0.011], resulting in non-significant lower arterial TBRs during VNS-off than VNS-on. Differences in the remaining tissues were not significant. Insulin levels increased after VNS was switched off [55.0 pmol/L (45.9–96.8) vs. 48.1 pmol/L (36.9–61.8); p = 0.047]. The concurrent increase in glucose levels was not statistically significant [4.8 mmol/L (4.7–5.3) vs. 4.6 mmol/L (4.5–5.2); p = 0.075]. Conclusions: Short-term discontinuation of VNS did not show a consistent change in arterial wall 18F-FDG-uptake. However, VNS did alter insulin and 18F-FDG blood levels, possibly as a result of sympathetic activation.

19 June 2024 in Cancers
Verified
Journal Article
Open access
PDF file
TWTineke van de Weijer
Tineke van de Weijer
WMWilhelmina L. van der Meer
Wilhelmina L. van der Meer
RMRik P. M. Moonen
Rik P. M. Moonen
TNThiemo J. A. van Nijnatten
Thiemo J. A. van Nijnatten
HGHester Gietema
Hester Gietema
FMFelix M. Mottaghy
Felix M. Mottaghy
Hybrid PET-MRI systems are being used more frequently. One of the drawbacks of PET-MRI imaging is its inferiority in detecting lung nodules, so it is often combined with a computed tomography (CT) of the chest. However, chest CT often detects additional, indeterminate lung nodules. The objective of this study was to assess the sensitivity of detecting metastatic versus indeterminate nodules with PET-MRI compared to chest CT. A total of 328 patients were included. All patients had a PET/MRI whole-body scan for (re)staging of cancer combined with an unenhanced chest CT performed at our center between 2014 and 2020. Patients had at least a two-year follow-up. Six percent of the patients had lung metastases at initial staging. The sensitivity and specificity of PET-MRI for detecting lung metastases were 85% and 100%, respectively. The incidence of indeterminate lung nodules on chest CT was 30%. The sensitivity of PET-MRI to detect indeterminate lung nodules was poor (23.0%). The average size of the indeterminate lung nodules detected on PET-MRI was 7 ± 4 mm, and the missed indeterminate nodules on PET-MRI were 4 ± 1 mm (p < 0.001). The detection of metastatic lung nodules is fairly good with PET-MRI, whereas the sensitivity of PET-MRI for detecting indeterminate lung nodules is size-dependent. This may be an advantage, limiting unnecessary follow-up of small, indeterminate lung nodules while adequately detecting metastases.

1 March 2018 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
JPJochem van der Pol
Jochem van der Pol
JVJudith de Vos-Geelen
Judith de Vos-Geelen
JBJan Bucerius
Jan Bucerius
CMCristina Mitea
Cristina Mitea
CLChristiaan van der Leij
Christiaan van der Leij
Selective internal radio therapy (SIRT) with Y-90-glass microspheres was performed in a cirrhotic patient with hepatocellular carcinoma (Barcelona Clinic Liver Cancer stage C) after arterial coil embolization for treatment of intratumoral hemorrhage and planned preoperative right portal vein embolization. Three technetium Tc-99m macro-albumin-aggregate injections were needed to optimize intralesional uptake without extrahepatic deposition. The consecutive SIRT treatment was uncomplicated with a remarkable result.