Lennart Scheys

Dr. Lennart Scheys

Department of Development and Regeneration, KU Leuven, 3000 Leuven, Belgium

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2008 in Gait & Posture
Verified
Journal Article
Closed access
LSLennart Scheys
Lennart Scheys
ACAnja Van Campenhout
Anja Van Campenhout
ASArthur Spaepen
Arthur Spaepen
PSPaul Suetens
Paul Suetens
IJIlse Jonkers
Ilse Jonkers

1 April 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
CJChrista de Jonge
Christa de Jonge
KLK. Lietaert
K. Lietaert
TST. van der Sloten
T. van der Sloten
BPB. Pouran
B. Pouran
AMA. Meynen
A. Meynen
AZA.A. Zadpoor
A.A. Zadpoor
The innovative design of orthopedic implants could play an important role in the development of life-lasting implants, by improving both primary and secondary implant fixations. The concept of meta-biomaterials aims to achieve a unique combination of mechanical, mass transport, and biological properties through optimized topological design of additively manufactured (AM) porous biomaterials. In this study, we primarily focused on a specific class of meta-biomaterials, namely auxetic meta-biomaterials. Their extraordinary behavior of lateral expansion in response to axial tension could potentially improve implant-bone contact in certain orthopedic applications. In this work, a multitude of auxetic meta-biomaterials were rationally designed and printed from Ti-6Al-4V using a commercially available laser powder bed fusion process called selective laser melting. The re-entrant hexagonal honeycomb unit cell was used as a starting point, which was then parametrically tuned to obtain a variety of mechanical and morphological properties. In this two-step study, the morphology and quasi-static properties of the developed meta-biomaterials were assessed using mechanical experiments accompanied with full-field strain measurements using digital image correlation. In addition, all our designs were computationally modelled using the finite element method. Our results showed the limits of the AM processes for the production of auxetic meta-biomaterials in terms of which values of the design parameters (e.g., re-entrant angle, relative density, and aspect ratio) could be successfully manufactured. We also found that the AM process itself imparts significant influence on the morphological and mechanical properties of the resulting auxetic meta-biomaterials. This further highlights the importance of experimental studies to determine the actual mechanical properties of such metamaterials. The elastic modulus and strength of many of our designs fell within the range of those reported for both trabecular and cortical bone. Unprecedented properties like these could be used to simultaneously address the different challenges faced in the mechanical design of orthopedic implants.

13 February 2018 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
TLThomas Luyckx
Thomas Luyckx
HVHilde Vandenneucker
Hilde Vandenneucker
LSLennart Scheys
Lennart Scheys
EVEvie Vereecke
Evie Vereecke
AIArnout Victor Ing
Arnout Victor Ing
JVJan Victor
Jan Victor
Background: In a typical osteoarthritic knee with varus deformity, distal femoral resection based off the worn medial femoral condyle may result in an elevated joint line. In a setting of fixed flexion contracture, the surgeon may choose to resect additional distal femur to obtain extension, thus purposefully raising the joint line. However, the biomechanical effect of raising the joint line is not well recognized. Questions/purposes: (1) What is the effect of the level of the medial joint line (restored versus raised) on coronal plane stability of a TKA? (2) Does coronal alignment technique (mechanical axis versus kinematic technique) affect coronal plane stability of the knee? (3) Can the effect of medial joint-line elevation on coronal plane laxity be predicted by an analytical model? Methods: A TKA prosthesis was implanted in 10 fresh frozen nonarthritic cadaveric knees with restoration of the medial joint line at its original level (TKA0). Coronal plane stability was measured at 0°, 30°, 60°, 90°, and 120° flexion using a navigation system while applying an instrumented 9.8-Nm varus and valgus force moment. The joint line then was raised in two steps by recutting the distal and posterior femur by an extra 2 mm (TKA2) and 4 mm (TKA4), downsizing the femoral component and, respectively, adding a 2- and a 4-mm thicker insert. This was done with meticulous protection of the ligaments to avoid damage. Second, a simplified two-dimensional analytical model of the superficial medial collateral ligament (MCL) length based on a single flexion-extension axis was developed. The effect of raising the joint line on the length of the superficial MCL was simulated. Results: Despite that at 0° (2.2° ± 1.5° versus 2.3° ± 1.1° versus 2.5° ± 1.1°; p = 0.85) and 90° (7.5° ± 1.9° versus 9.0° ± 3.1° versus 9.0° ± 3.5°; p = 0.66), there was no difference in coronal plane laxity between the TKA0, TKA2, and TKA4 positions, increased laxity at 30° (4.8° ± 1.9° versus 7.9° ± 2.3° versus 10.2° ± 2.0°; p < 0.001) and 60° (5.7° ± 2.7° versus 8.8° ± 2.9° versus 11.3° ± 2.9°; p < 0.001) was observed when the medial joint line was raised 2 and 4 mm. At 30°, this corresponds to an average increase of 64% (3.1°; p < 0.01) in mid-flexion laxity with a 2-mm raised joint line and a 111% (5.4°; p < 0.01) increase with a 4-mm raised joint line compared with the 9-mm baseline resection. No differences in coronal alignment were found between the knees implanted with kinematic alignment versus mechanical alignment at any flexion angle. The analytical model was consistent with the cadaveric findings and showed lengthening of the superficial MCL in mid-flexion. Conclusions: Despite a well-balanced knee in full extension and at 90° flexion, increased mid-flexion laxity in the coronal plane was evident in the specimens where the joint line was raised. Clinical Relevance: When recutting the distal and posterior femur and downsizing the femoral component, surgeons should be aware that this action might increase the laxity in mid-flexion, even if the knee is stable at 0° and 90°.

1 November 2008 in Gait & Posture
Verified
Journal Article
Closed access
LSLennart Scheys
Lennart Scheys
ASArthur Spaepen
Arthur Spaepen
PSPaul Suetens
Paul Suetens
IJIlse Jonkers
Ilse Jonkers

9 November 2013 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
THThomas J. Heyse
Thomas J. Heyse
BEBilal F. El‐Zayat
Bilal F. El‐Zayat
RCRonny De Corte
Ronny De Corte
YCYan Chevalier
Yan Chevalier
LSLennart Scheys
Lennart Scheys
LLLuc Labey
Luc Labey

1 February 2011 in Gait & Posture
Verified
Journal Article
Closed access
LSLennart Scheys
Lennart Scheys
KDKaat Desloovere
Kaat Desloovere
ASArthur Spaepen
Arthur Spaepen
PSPaul Suetens
Paul Suetens
IJIlse Jonkers
Ilse Jonkers