Kashish Kumar

Dr. Kashish Kumar

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
KKKashish Kumar
Kashish Kumar
ASAlok Singh
Alok Singh
Shaik SaboorShaik Saboor
Shaik Saboor
C Ahamed SaleelC Ahamed Saleel
C Ahamed Saleel
Abdul AabidAbdul Aabid
Abdul Aabid
Muneer BaigMuneer Baig
Muneer Baig
Conventional air conditioners (AC) operate on vapor compression refrigeration (VCR) technology, which is a heavy consumer of electricity, and the used refrigerants harm the environment. In humid and hot areas, a liquid desiccant AC system integrated with a VCR system has been proposed as a better alternative to traditional standalone VCR system, as it is an energy-efficient system that can remove latent air load, air pollutants from the processed air, and it is energy-saving. In this study, a hybrid liquid desiccant air conditioning (LDAC) system with a capacity of 5.5 kW was designed and developed by integrating these two different technologies, and the vapor pressure of potassium formate (KCOOH) solution at different solution temperatures and concentrations were monitored experimentally to determine the optimal concentration range. Moreover, a comparative study was conducted to analyze the dehumidification performance of lithium chloride (LiCl) and KCOOH solutions. Experiments are designed by using Minitab 19 software, which employs the design of an experimental technique through full factorial design by considering four variables, namely, type of desiccant, inlet air flow rate, inlet desiccant temperature, and inlet air humidity. To study and compare dehumidification characteristics of both solutions, three responses were considered, i.e., the coefficient of performance of a hybrid system, the heat load of dehumidifier, and specific humidity change. Experimental results revealed that 70% of KCOOH solution exhibited comparable vapor pressure to that of 36% LiCl solution. Additionally, the dehumidification ability of the KCOOH solution was better than that of the LiCl solutions.

7 August 2022 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
KKKashish Kumar
Kashish Kumar
ASAlok Singh
Alok Singh
Air-conditioning (AC) systems, which operate on traditional vapor compression refrigeration (VCR) systems, consume a substantial proportion of the world’s electricity consumed by the building industry. In the scope of decreasing greenhouse gas emissions, energy consumption, heating, ventilation, and air conditioning industries have focused on finding alternatives to electrically operated VCR systems. A combination of a liquid desiccant dehumidification system (LDDS) with a VCR system has been recommended as a superior substitute in warm and moist climates. The focus of this research article is to design and fabricate a small-scale 5 kW hybrid LDDS system by integrating the distinct technologies mentioned above. Additionally, data collected on the vapor pressure of potassium formate (KCOOH) at various solution concentrations and temperatures is being collected to assist in encouraging research and determine the optimal concentration range. In this study, experimental analysis and comparison of dehumidification performance was conducted between two desiccants by analyzing the effects of input variables ( ma, Td, and ωs) on the output response ( Δω, Qdeh, and COPh). The results showed that the solution with a 69.92% KCOOH concentration had nearly the same vapor pressure as a solution with a 35% LiCl concentration. Moreover, it was revealed that the lowest values of ma and Td and the highest value of ωs yield maximum values of the output responses. At the same combination of input variables, the KCOOH desiccant has a much higher hybrid system coefficient of performance than the LiCl desiccant.

27 December 2022 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
KKKashish Kumar
Kashish Kumar
ASAlok Singh
Alok Singh
PCPREM KUMAR CHAURASIYA
PREM KUMAR CHAURASIYA
KPKamal Kishore Pathak
Kamal Kishore Pathak
VPVikas Pandey
Vikas Pandey

29 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
KKKashish Kumar
Kashish Kumar
ASAlok Singh
Alok Singh
A liquid desiccant dehumidification cooling system is a promising, energy-saving, high-efficiency, environmentally friendly technology that maintains thermal comfort effectively indoors by utilizing renewable energy sources or waste heat to enhance system efficiency. In this research, a small-scale (6 kW cooling capacity) hybrid liquid desiccant air-conditioning system (HLDAC) is proposed to evaluate the dehumidification performance of a non-corrosive potassium formate (KCOOH) solution. For this, four input parameters, namely, inlet air flow rate, inlet desiccant temperature, inlet desiccant concentration, and inlet specific air humidity, were selected. Moreover, the different combinations of experiments were designed by employing response surface methodology (RSM) to evaluate the dehumidification performance parameters, namely, dehumidifier latent heat load, coefficient of performance of hybrid system, and moisture removal rate (MRR). Further, a comparative performance analysis between the hybrid system and a standalone vapor compression system (VCS) unit was carried out. The result showed a remarkable increase in coefficient of performance, which was observed at about 28.48% over the standalone VCS unit. Furthermore, the economic assessment of the proposed hybrid system is presented in this paper. Finally, from the economic analysis, it was concluded that the hybrid system had a payback time of 2.65 years compared to the VCS unit.

27 May 2025 in Renewable Energy
Verified
Journal Article
Closed access
KKKashish Kumar
Kashish Kumar
MSMoin Ali Syed
Moin Ali Syed
GAGurubalan Annadurai
Gurubalan Annadurai

27 May 2025 in Solar Compass
Verified
Journal Article
Open access
KKKashish Kumar
Kashish Kumar
GAGurubalan Annadurai
Gurubalan Annadurai
ASAlok Singh
Alok Singh