According to the literature, there are many mathematical relationships between density of the trabecular bone and mechanical properties obtained in macro-scale testing. In micro-scale, the measurements provide only the ranges of Young׳s modulus of trabeculae, but there are no experimentally tested relationships allowing the calculation of the distribution of Young׳s modulus of trabeculae within these experimental ranges. This study examined the applicability of relationships between bone density and mechanical properties obtained in macro-scale testing for the calculation of Young׳s modulus distribution in micro-scale. Twelve cubic specimens from eleven femoral heads were cut out and micro-computed tomography (micro-CT) scanned. A mechanical compression test and Digital Image Correlation (DIC) measurements were performed to obtain the experimental displacement and strain full-field evaluation for each specimen. Five relationships between bone density and Young׳s modulus were selected for the test; those were given by Carter and Hayes (1977), Ciarelli et al. (2000), Kaneko et al. (2004), Keller (1994) for the human femur, and Li and Aspden, 1997. Using these relationships, five separate finite element (FE) models were prepared, with different distribution of Young׳s modulus of trabeculae for each specimen. In total, 60 FE analyses were carried out. The obtained displacement and strain full-field measurements from numerical calculations and experiment were compared. The results indicate that the highest accuracy of the numerical calculation was obtained for the Ciarelli et al. (2000) relationship, where the relative error was 17.87% for displacements and 50.94 % for strains. Therefore, the application of the Ciarelli et al. (2000) relationship in the microscale linear FE analysis is possible, but mainly to determine bone displacement.
Nowadays, there are four types of meniscal allografts known: fresh, cryopreserved, deep-frozen and lyophilized ones but only two of them are widely used in clinical practice. Use of different types of meniscal allografts still remains controversial due to preparation method, their biomechanical properties as well as cost which is connected with processing and storage. The main aim of this review is to present the current status of knowledge concerning meniscal allograft preservation and sterilization, especially the advantages and disadvantages of each method. Authors wanted to show a broad spectrum of methods used and conceptions presented by other authors. The second aim is to gather available information about meniscal preservation and sterilization methods in one paper. Deep-frozen and cryopreserved meniscal allografts are the most frequently used ones in the clinical practice. The use of fresh grafts stays controversial but also has many followers. Lyophilized grafts in turn are not applied at present due to some serious drawbacks including reduction of tensile strength, poor rehydration, graft shrinkage and post-transplantation joint effusion as well as increased risk of meniscal size reduction. An application of sterilizing agents make the meniscal allograft free from the bacteria and viruses, but also it may cause serious structure changes. Therefore, choosing just one ideal method of meniscal allograft preservation and sterilization is complicated and should be based on broad knowledge and experience of surgeon performing the transplantation.
28 October 2016 in The Physician and Sportsmedicine
Nowadays, bone tunnel enlargement (BTE) after anterior cruciate ligament reconstruction is a well-known phenomenon. It has been identified, investigated and described by many authors during the last thirty years. Nevertheless, the etiology of bone tunnel enlargement still remains unclear. It is known that the causes are multifactorial and may include the surgical technique, the method of fixation, materials used, type of graft as well as biological factors. Due to the recent popularization of the use of hamstring grafts in anterior cruciate ligament reconstruction, the bone tunnel enlargement phenomenon is becoming increasingly common. In this review article, the authors focus on compiling current knowledge about the etiology, diagnosis, and the possibility of reducing the occurrence of this phenomenon by using the latest methods of supporting reconstruction surgery.
Contemporary ophthalmology knows many methods of measuring intraocular pressure, namely the methods of non-contact and impression applanation tonometry. In non-contact applanation tonometers, e.g. the Corvis, the corneal flattening is caused by an air puff. Image registration of the corneal deflection performed by a tonometer enables to determine other interesting biomechanical parameters of the eye, which are not available in the tonometer. The measurement of new selected parameters is presented in this paper. Images with an M × N × I resolution of 200 × 576 × 140 pixels were acquired from the Corvis device in the source recording format *.cst. A total of 13'400 2D images of patients examined routinely in the Clinical Department of Ophthalmology, in District Railway Hospital in Katowice, Poland, were analysed in accordance with the Declaration of Helsinki. A new method has been proposed for the analysis of corneal deflection images in the Corvis tonometer with the use of the Canny edge detection method, mathematical morphology methods and context-free operations. The resulting image analysis tool allows determination of the response of the cornea and the entire eyeball to an air puff. The paper presents the method that enables the measurement of the amplitude of curvature changes in the frequency range from 150 to 500 Hz and automatic designation of the eyeball movement direction. The analysis of these data resulted in 3 new features of dynamics of the eye reaction to an air puff. Classification of these features enabled to propose 4 classes of deformation. The proposed algorithm allows to obtain reproducible results fully automatically at a time of 5 s per patient using the Core i5 CPU M460 @ 2.5GHz 4GB of RAM. The paper presents the possibility of using a profiled algorithm of image analysis, proposed by the authors, to measure additional cornea deformation parameters. The new tool enables automatic measurement of the additional new parameters when using the Corvis tonometer. A detailed clinical examination based on this method will be presented in subsequent papers.
Headache is a common health problem in childhood. Children's drawings are helpful in the diagnosis of headache type. Children, especially younger ones, communicate better through pictures than verbally. The aim of the present study is to evaluate the usefulness of drawings of the child's headache in the diagnostic process carried out by a pediatrician and a pediatric neurologist. At the beginning of a visit in a neurological clinic, or on the first day of hospitalization, the child was asked, “Please draw your headache,” or “How do you feel your headache?” without any additional explanations or suggestions. Clinical diagnosis of headache type was made on the basis of the standard diagnostic evaluation. For the purpose of this study, children's headaches were categorized as migraine, tension-type headache, or “the others.” One hundred twenty-four drawings of children with headaches were analyzed by 8 pediatricians and 8 pediatric neurologists. The analysts were unaware of the clinical history, age, sex, and diagnosis of the patients. The clinical diagnosis was considered the “gold standard” to which the headache drawing diagnosis was compared. There were 68 girls 5—18 years of age and 56 boys 7—18 years of age. Of the 124 children, 40 were clinically diagnosed with migraine (32.2%), 47 with tension-type headache (37.9%), and 37 (29.8%) as the others. Children with migraine most frequently draw sharp elements. Children with tension-type headache mainly drew compression elements and pressing elements. In the group of “the other” headaches, 21 children were diagnosed with somatoform disorders. The most frequent element in this group's drawings was a whirl in the head. Colors used most frequently were black and red, which signify severe pain. There was no difference in sensitivity of diagnoses between neurologists and pediatricians. Because the evaluation of drawings by children with headaches done both by pediatricians and pediatric neurologists was correct for approximately half of the children, the authors decided to prepare a set of test pictures, including characteristic presentations of pain. Preparing a ready set of test drawings may facilitate differentiation for the inexperienced doctors and encourage those children who refuse to draw.
This paper describes a method for automatic analysis of the choroid in OCT images of the eye fundus in ophthalmology. The problem of vascular lesions occurs e.g. in a large population of patients having diabetes or macular degeneration. Their correct diagnosis and quantitative assessment of the treatment progress are a critical part of the eye fundus diagnosis. The study analysed about 1’000 OCT images acquired using SOCT Copernicus (Optopol Tech. SA, Zawiercie, Poland). The proposed algorithm for image analysis enabled to analyse the texture of the choroid portion located beneath the RPE (Retinal Pigment Epithelium) layer. The analysis was performed using the profiled algorithm based on morphological analysis and texture analysis and a classifier in the form of decision trees. The location of the centres of gravity of individual objects present in the image beneath the RPE layer proved to be important in the evaluation of different types of images. In addition, the value of the standard deviation and the number of objects in a scene were equally important. These features enabled classification of three different forms of the choroid that were related to retinal pathology: diabetic edema (the classification gave accuracy ACC1 = 0.73), ischemia of the inner retinal layers (ACC2 = 0.83) and scarring fibro vascular tissue (ACC3 = 0.69). For the cut decision tree the results were as follows: ACC1 = 0.76, ACC2 = 0.81, ACC3 = 0.68. The created decision tree enabled to obtain satisfactory results of the classification of three types of choroidal imaging. In addition, it was shown that for the assumed characteristics and the developed classifier, the location of B-scan does not significantly affect the results. The image analysis method for texture analysis presented in the paper confirmed its usefulness in choroid imaging. Currently the application is further studied in the Clinical Department of Ophthalmology in the District Railway Hospital in Katowice, Medical University of Silesia, Poland.