Łukasz Cyganik

Łukasz Cyganik

Auto-generated profile, based on publicly available information

Łukasz Cyganik

Łukasiewicz Research Network – Upper-Silesian Institute of Technology

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
ŁCŁukasz Cyganik
Łukasz Cyganik
MBMarcin Binkowski
Marcin Binkowski
GKGrzegorz Kokot
Grzegorz Kokot
TRTomasz Rusin
Tomasz Rusin
PPPaulina Popik
Paulina Popik
AJAntoni John
Antoni John
According to the literature, there are many mathematical relationships between density of the trabecular bone and mechanical properties obtained in macro-scale testing. In micro-scale, the measurements provide only the ranges of Young׳s modulus of trabeculae, but there are no experimentally tested relationships allowing the calculation of the distribution of Young׳s modulus of trabeculae within these experimental ranges. This study examined the applicability of relationships between bone density and mechanical properties obtained in macro-scale testing for the calculation of Young׳s modulus distribution in micro-scale. Twelve cubic specimens from eleven femoral heads were cut out and micro-computed tomography (micro-CT) scanned. A mechanical compression test and Digital Image Correlation (DIC) measurements were performed to obtain the experimental displacement and strain full-field evaluation for each specimen. Five relationships between bone density and Young׳s modulus were selected for the test; those were given by Carter and Hayes (1977), Ciarelli et al. (2000), Kaneko et al. (2004), Keller (1994) for the human femur, and Li and Aspden, 1997. Using these relationships, five separate finite element (FE) models were prepared, with different distribution of Young׳s modulus of trabeculae for each specimen. In total, 60 FE analyses were carried out. The obtained displacement and strain full-field measurements from numerical calculations and experiment were compared. The results indicate that the highest accuracy of the numerical calculation was obtained for the Ciarelli et al. (2000) relationship, where the relative error was 17.87% for displacements and 50.94 % for strains. Therefore, the application of the Ciarelli et al. (2000) relationship in the microscale linear FE analysis is possible, but mainly to determine bone displacement.

15 November 2022 in Archives of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
Tomasz WolnikTomasz Wolnik
Tomasz Wolnik
SOSzczepan Opach
Szczepan Opach
ŁCŁukasz Cyganik
Łukasz Cyganik
TJTomasz Jarek
Tomasz Jarek
VSVojtech Szekeres
Vojtech Szekeres
Fractional slot PMSM motors enable high power density factors to be obtained provided that their electromagnetic circuit, appropriate mechanical structure and cooling system are properly designed, as well as when operating at a high frequency of power supply voltage (400–800 Hz) with high magnetic saturation and high current loads (approx. 12–15 A/mm2). Such operating conditions, especially in the case of fractional slot motors, may be the reason for excessive rotor losses, mainly in the rotor yoke and permanent magnets. One of the conditions for obtaining high values of continuous power of the motor is the reduction of these losses. This paper presents selected design methods for limiting the value of rotor losses with simultaneous consideration of their influence on other motor parameters. The analysiswas carried out for aPMSMmotor with an external rotorweighting approx. 10 kg and a maximum power of 50 kW at a rotational speed of 4 800 rpm.

23 November 2017 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
ŁCŁukasz Cyganik
Łukasz Cyganik
MBMarcin Binkowski
Marcin Binkowski
GKGrzegorz Kokot
Grzegorz Kokot
PCPaulina Cyganik
Paulina Cyganik
TRTomasz Rusin
Tomasz Rusin
AJAntoni John
Antoni John
The study presents an experimental verification of Wagner et al.’s relationship in microscale and proposes a modification of this relationship. For this purpose, 11 cubic specimens were microcomputed tomography scanned and mechanically tested with the displacement full-field measurements using a digital image correlation system. Then, numerical simulations of the compression tests were performed using a finite elements method. The Young’s modulus distributions assigned to the finite elements models were calculated using both of Wagner et al.’s relationships: original and modified. Comparison of the experimental and numerical results indicated the accuracy of numerical solutions for both relationships.

15 January 2019 in MATEC Web of Conferences
Verified
Journal Article
Open access
EGElzbieta Gawronska
Elzbieta Gawronska
RDRobert Dyja
Robert Dyja
Bartłomiej BędkowskiBartłomiej Będkowski
Bartłomiej Będkowski
ŁCŁukasz Cyganik
Łukasz Cyganik
The aim of the work is the modeling of the heat flow in an electric motor with permanent magnets with a height of 56mm. Numerical calculations were carried out for a simplified 3D model prepared in the Autodesk Inventor solid modeling program. The bodies were prepared from the existing model and constructional documentation of the actual engine. In the next step, the simplified solid model was imported into a commercial Autodesk Simulation Multiphysics computing package and into authorial software in which it was supplied with appropriate material properties and discretized. In the next stage, the model was calibrated and verified by a preheating attempt of the actual object. The motor winding was supplied with direct current and was a heat source with a power of 40 W. Temperatures were recorded at selected points in the steady state. Then, on a discredited numerical model, computer simulations corresponding to the actual heating test were carried out. When comparing the temperature values obtained at the points corresponding to the measurement points, the model was calibrated, which corrected the thermal resistance parameters assumed in the calculation model. Finally, the model (after the implemented changes) was verified with results obtained with commercial and authorial software.

20 April 2016
Verified
Book Chapter
Closed access
ŁCŁ Cyganik
Ł Cyganik
MBM Binkowski
M Binkowski
PPP Popik
P Popik
ZWZygmunt Wrobel
Zygmunt Wrobel
GKGrzegorz Kokot
Grzegorz Kokot
RNR Nowak
R Nowak

1 January 2014
Verified
Book Chapter
Closed access
PDF file
PPPaulina Popik
Paulina Popik
MBMarcin Binkowski
Marcin Binkowski
ŁCŁukasz Cyganik
Łukasz Cyganik
FBFilip Bolechała
Filip Bolechała
RNRoman Nowak
Roman Nowak
ZWZygmunt Wrobel
Zygmunt Wrobel