Excessive levels of organic matter in water threaten ecological safety and endanger human health. As the water resource environment is deteriorating, accurate and rapid determination of water quality parameters has become a current research hotspot. In recent years, the ultraviolet spectrometry method has been more widely used in the detection of chemical oxygen demand (COD), which is convenient and without chemical reagents. However, this method tends to use absorbance at 254 nm to measure COD. It has a good detection effect when the composition of pollutants is single, but in real life, the complex composition of pollutants will seriously affect the accuracy of measurement. Therefore, a COD prediction model based on ultraviolet-visible (UV-Vis) spectrometry and the convolutional neural network (CNN) is proposed. Compared with other traditional COD prediction models, this model makes full use of the absorbance of all ultraviolet and visible wavelengths, avoiding the information loss caused by using specific wavelengths. Meanwhile, this model is constructed based on the shallow CNN, using convolutional layers with different step lengths instead of the traditional pooling layers, which reduces computation and enhances the capture of spectral feature peaks. Additionally, with the powerful feature extraction capability of the CNN, this model reduces the reliance on pre-processing methods and improves the utilization of spectral information. Experiments have shown that our model has better fitting results and accuracy than other traditional COD prediction models such as the principal component analysis (PCA), partial least squares regression (PLSR), and backpropagation (BP) neural network. This study provides a better solution for improving the accuracy of UV-Vis water quality COD detection, which is conducive to real-time monitoring of the water quality, providing data support of water pollution and its development trend for the government’s water resource protection policy and promoting biodiversity development.
Gas detection and monitoring are critical to protect human health and safeguard the environment and ecosystems. Chemiresistive sensors are widely used in gas monitoring due to their ease of fabrication, high customizability, mechanical flexibility, and fast response time. However, with the rapid development of industrialization and technology, the main challenges faced by chemiresistive gas sensors are poor selectivity and insufficient anti-interference stability in complex application environments. In order to overcome these shortcomings of chemiresistive gas sensors, the pattern recognition method is emerging and is having a great impact in the field of sensing. In this review, we focus systematically on the advancements in the field of data processing methods for feature extraction, such as the methods of determining the characteristics of the original response curve, the curve fitting parameters, and the transform domain. Additionally, we emphasized the developments of traditional recognition algorithms and neural network algorithm in gas discrimination and analyzed the advantages through an extensive literature review. Lastly, we summarized the research on chemiresistive gas sensors and provided prospects for future development.
The turbidity interference caused by suspended particles in water seriously affects the accuracy of ultraviolet-visible spectroscopy in detecting water quality chemical oxygen demand. Based on this, the application of ultraviolet-visible spectroscopy to detect water quality chemical oxygen demand usually requires physical and mathematical methods to correct the spectral baseline interference caused by turbidity. Because of the slow response speed and unstable compensation effect of traditional correction methods, this paper proposes to use a compressed sensing algorithm to perform baseline correction and achieve good results. In the experiment, we selected formazin turbidity solution and sodium oxalate standard solution and carried out the research on the algorithm of turbidity correction for detecting chemical oxygen demand of water quality by ultraviolet-visible spectroscopy. The experiment obtains the absorption spectra of different concentrations of formazine turbidity solutions and the same concentration of sodium oxalate with different turbidity standard solutions at 210∼845 nm and analyzes the nonlinear effect of absorbance on turbidity. This article uses standard solution experiments to explore the compressed sensing theory for turbidity correction, and through the correction of the absorption spectrum of the actual water sample, it verifies the feasibility of the compression theory for turbidity correction. The method effectively corrects the baseline shift or drift of the water quality ultraviolet-visible absorption spectrum caused by suspended particles, while retaining the absorption characteristics of the ultraviolet spectrum, and it can effectively improve the accuracy and accuracy of the ultraviolet-visible spectroscopy water quality chemical oxygen demand detection.
For bench-top X-ray fluorescence computed tomography (XFCT), the X-ray tube source will bring extreme Compton background noise, resulting in a low signal-to-noise ratio and low contrast detection limit. In this paper, a noise2noise denoising algorithm based on the UNet deep learning network is proposed. The network can use noise image learning to convert the noise image into a clean image. Two sets of phantoms (high concentration Gd phantom and low concentration Bi phantom) are used for scanning to simulate the imaging process under different noise levels and generate the required data set. Additionally, the data set is generated by Geant4 simulation. In the training process, the L1 loss function is used for its good convergence. The image quality is evaluated according to CNR and pixel profile, which shows that our algorithm is better than BM3D, both visually and quantitatively.
In order to ensure the safety of steel wire rope in various application scenarios, it is particularly important to quantitatively detect the defects of wire rope. Complex detection conditions affect the detection efficiency of wire rope. Therefore, based on the magnetic flux leakage method, this study proposes a method to identify the damage width of steel wire rope for multi-channel fusion of a Hall sensor array. Firstly, the Hall sensor array is used to capture the magnetic flux leakage data of steel wire rope; then, continuous wavelet transform is used to decompose the original data, and moving average filtering is used to denoise each component; the denoised components are merged and converted into a time spectrum, and the time spectrum is classified by ResNet50 image classification model to realize the detection of wire rope damage width. According to the dataset used in this study, the results show that the proposed method performs best in the mainstream noise reduction model; detection accuracy for the width of damage in steel wire ropes is 97%, which proves that the proposed method is effective and feasible.
1 September 2021 in Journal of Physics: Conference Series
Aiming at the problems of low detection accuracy, large size and quality of the detection equipment, and difficulty in online monitoring in the magnetic flux leakage detection of elevator wire ropes, a broken wire signal acquisition system was built based on the tunnel magnetoresistance sensor TMR2703, and a dual-loop excitation device was designed and simulated to verify. The dipole model determines the detection direction of the sensor, acquires the magnetic flux leakage signal with the signal preprocessing circuit and the differential detection ring, develops the host computer in LabVIEW, displays the broken wire signal waveform in real time, and stores the collected data in the form of TDMS files, completed the feature extraction of broken wire signals. Experiments show that the system can collect the magnetic flux leakage signal of the wire rope in real time, and can accurately extract the characteristic value of the magnetic flux leakage signal with different numbers of broken wires. The peak value, valley value, peak-to-peak value and signal wave width of the signal have an increase with the number of broken wires. The law of increase can be used to judge the damage degree of the wire rope according to the detection waveform.