Michael Aaron McGeehan

Dr. Michael Aaron McGeehan

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2016 in Experimental Brain Research
Verified
Journal Article
Closed access
PDF file
MMMichael Aaron McGeehan
Michael Aaron McGeehan
MWMarjorie H. Woollacott
Marjorie H. Woollacott
BDBrian Dalton
Brian Dalton

4 October 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MMMichael Aaron McGeehan
Michael Aaron McGeehan
SKSalil Sidharthan Karipott
Salil Sidharthan Karipott
Michael HahnMichael Hahn
Michael Hahn
DMDavid C. Morgenroth
David C. Morgenroth
Keat Ghee OngKeat Ghee Ong
Keat Ghee Ong
There is an increasing need for tactile shear sensors, particularly for medical applications such as orthopedic rehabilitation. Examples include measuring interfacial shear stresses between a residual limb and prosthesis to monitor socket fit and improve residual limb tissue health, and tracking shearing between a foot and shoe for assessing performance in athletes. However, there are considerable challenges in implementing shear force sensors for orthopedic applications due to the requirements for noninvasiveness, low mass, low power, and robustness against motion artifacts, normal force, and/or electromagnetic fields. To address these challenges, we designed, fabricated, and characterized a simple, low-cost, optoelectronic sensor that can measure multi-axial shear stresses. This novel sensor is based on a red, green, and blue (RGB) light-emitting diode (LED) projecting a cyclic illumination of RGB light onto a color pattern surface. As shear strain causes a displacement between the LED and the color pattern, the intensities of the reflected lights change due to the shift of the color pattern position. A photodiode captures the reflected light intensity at each color illumination, allowing the determination of the color pattern surface displacement and the shear along two axes. In this paper, we also report the efficacy of the sensor under benchtop testing conditions, confirming the potential of this technology for shear monitoring in orthopedic devices such as protheses or shoes. Future efforts will focus on miniaturization and packaging of the sensors, and characterizing their performance for the aforementioned medical applications.

20 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
XYXun Yu
Xun Yu
Keat Ghee OngKeat Ghee Ong
Keat Ghee Ong
MMMichael Aaron McGeehan
Michael Aaron McGeehan
The Fitzpatrick Skin Phototype Classification (FSPC) scale is widely used to categorize skin types but has limitations such as the underrepresentation of darker skin phototypes, low classification resolution, and subjectivity. These limitations may contribute to dermatological care disparities in patients with darker skin phototypes, including the misdiagnosis of wound healing progression and escalated dermatological disease severity. This study introduces (1) an optical sensor measuring reflected light across 410–940 nm, (2) an unsupervised K-means algorithm for skin phototype classification using broadband optical data, and (3) methods to optimize classification across the Near-ultraviolet-A, Visible, and Near-infrared spectra. The differentiation capability of the algorithm was compared to human assessment based on FSPC in a diverse participant population (n = 30) spanning an even distribution of the full FSPC scale. The FSPC assessment distinguished between light and dark skin phototypes (e.g., FSPC I vs. VI) at 560, 585, and 645 nm but struggled with more similar phototypes (e.g., I vs. II). The K-means algorithm demonstrated stronger differentiation across a broader range of wavelengths, resulting in better classification resolution and supporting its use as a quantifiable and reproducible method for skin type classification. We also demonstrate the optimization of this method for specific bandwidths of interest and their associated clinical implications.

22 September 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
MMMichael Aaron McGeehan
Michael Aaron McGeehan
Peter AdamczykPeter Adamczyk
Peter Adamczyk
KNKieran Marc Nichols
Kieran Marc Nichols
Michael HahnMichael Hahn
Michael Hahn
Introduction: Simulations based on computational musculoskeletal models are powerful tools for evaluating the effects of potential biomechanical interventions, such as implementing a novel prosthesis. However, the utility of simulations to evaluate the effects of varied prosthesis design parameters on gait mechanics has not been fully realized due to the lack of a readily-available limb loss-specific gait model and methods for efficiently modeling the energy storage and return dynamics of passive foot prostheses. The purpose of this study was to develop and validate a forward simulation-capable gait model with lower-limb loss and a semi-active variable-stiffness foot (VSF) prosthesis. Methods: A seven-segment 28-DoF gait model was developed and forward kinematics simulations, in which experimentally observed joint kinematics were applied and the resulting contact forces under the prosthesis evolved accordingly, were computed for four subjects with unilateral below-knee amputation walking with a VSF. Results: Model-predicted resultant ground reaction force (GRFR) matched well under trial-specific optimized parameter conditions (mean R2: 0.97, RMSE: 7.7% body weight (BW)) and unoptimized (subject-specific, but not trial-specific) parameter conditions (mean R2: 0.93, RMSE: 12% BW). Simulated anterior-posterior center of pressure demonstrated a mean R2 = 0.64 and RMSE = 14% foot length. Simulated kinematics remained consistent with input data (0.23 deg RMSE, R2 > 0.99) for all conditions. Conclusions: These methods may be useful for simulating gait among individuals with lower-limb loss and predicting GRFR arising from gait with novel VSF prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.

2 April 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MMMichael Aaron McGeehan
Michael Aaron McGeehan
Peter AdamczykPeter Adamczyk
Peter Adamczyk
KNKieran Marc Nichols
Kieran Marc Nichols
Michael HahnMichael Hahn
Michael Hahn
Passive energy storage and return (ESR) feet are current performance standard in lower limb prostheses. A recently developed semi-active variable-stiffness foot (VSF) prosthesis balances the simplicity of a passive ESR device with the adaptability of a powered design. The purpose of this study was to model and simulate the ESR properties of the VSF prosthesis. The ESR properties of the VSF were modeled as a lumped parameter overhung beam. The overhung length is variable, allowing the model to exhibit variable ESR stiffness. Foot-ground contact was modeled using sphere-to-plane contact models. Contact parameters were optimized to represent the geometry and dynamics of the VSF and its foam base. Static compression tests and gait were simulated. Simulation outcomes were compared to corresponding experimental data. Stiffness of the model matched that of the physical VSF (R2: 0.98, root-mean-squared error (RMSE): 1.37 N/mm). Model-predicted resultant ground reaction force (GRFR) matched well under optimized parameter conditions (R2: 0.98, RMSE: 5.3% body weight,) and unoptimized parameter conditions (R2: 0.90, mean RMSE: 13% body weight). Anterior–posterior center of pressure matched well with R2 > 0.94 and RMSE < 9.5% foot length in all conditions. The ESR properties of the VSF were accurately simulated under benchtop testing and dynamic gait conditions. These methods may be useful for predicting GRFR arising from gait with novel prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.

20 October 2022 in Measurement Science and Technology
Verified
Journal Article
Closed access
MMMichael Aaron McGeehan
Michael Aaron McGeehan
MHMichael Hahn
Michael Hahn
SKSalil Karipott
Salil Karipott
KOKeat Ghee Ong
Keat Ghee Ong
The need for miniaturized shear force sensors is expanding, particularly for biomedical applications. Examples include measuring interfacial shear stresses between a human and an external device (e.g. footwear or a prosthesis). However, there are considerable challenges in designing a shear sensor for these applications due to the need for a small package, low power requirements, and resistance to interference from motion artifact and electromagnetic fields. This paper presents the design, fabrication, and characterization sensor that measures two-axis shear force by detecting displacement between a color panel and a red, green, and blue light-sensing photodiode. The sensor response to applied displacements and forces was characterized under benchtop testing conditions. We also present the design of a prototype wireless version of the sensor for integration into footwear. The sensor exhibited strong agreement with gold standard measurements for two-axis shear displacements (R 2 > 0.99, RMSE ⩽ 5.0 µm) and forces (R 2 > 0.99, RMSE ⩽ 0.94 N). This performance, along with the sensor’s scalability, miniaturized form, and low power requirements make it well-suited a variety of biomedical applications.