Kieran Marc Nichols

Dr. Kieran Marc Nichols

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

2 April 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
MMMichael Aaron McGeehan
Michael Aaron McGeehan
Peter AdamczykPeter Adamczyk
Peter Adamczyk
KNKieran Marc Nichols
Kieran Marc Nichols
Michael HahnMichael Hahn
Michael Hahn
Passive energy storage and return (ESR) feet are current performance standard in lower limb prostheses. A recently developed semi-active variable-stiffness foot (VSF) prosthesis balances the simplicity of a passive ESR device with the adaptability of a powered design. The purpose of this study was to model and simulate the ESR properties of the VSF prosthesis. The ESR properties of the VSF were modeled as a lumped parameter overhung beam. The overhung length is variable, allowing the model to exhibit variable ESR stiffness. Foot-ground contact was modeled using sphere-to-plane contact models. Contact parameters were optimized to represent the geometry and dynamics of the VSF and its foam base. Static compression tests and gait were simulated. Simulation outcomes were compared to corresponding experimental data. Stiffness of the model matched that of the physical VSF (R2: 0.98, root-mean-squared error (RMSE): 1.37 N/mm). Model-predicted resultant ground reaction force (GRFR) matched well under optimized parameter conditions (R2: 0.98, RMSE: 5.3% body weight,) and unoptimized parameter conditions (R2: 0.90, mean RMSE: 13% body weight). Anterior–posterior center of pressure matched well with R2 > 0.94 and RMSE < 9.5% foot length in all conditions. The ESR properties of the VSF were accurately simulated under benchtop testing and dynamic gait conditions. These methods may be useful for predicting GRFR arising from gait with novel prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.

22 September 2021 in Journal of Biomechanical Engineering
Verified
Journal Article
Open access
PDF file
MMMichael Aaron McGeehan
Michael Aaron McGeehan
Peter AdamczykPeter Adamczyk
Peter Adamczyk
KNKieran Marc Nichols
Kieran Marc Nichols
Michael HahnMichael Hahn
Michael Hahn
Introduction: Simulations based on computational musculoskeletal models are powerful tools for evaluating the effects of potential biomechanical interventions, such as implementing a novel prosthesis. However, the utility of simulations to evaluate the effects of varied prosthesis design parameters on gait mechanics has not been fully realized due to the lack of a readily-available limb loss-specific gait model and methods for efficiently modeling the energy storage and return dynamics of passive foot prostheses. The purpose of this study was to develop and validate a forward simulation-capable gait model with lower-limb loss and a semi-active variable-stiffness foot (VSF) prosthesis. Methods: A seven-segment 28-DoF gait model was developed and forward kinematics simulations, in which experimentally observed joint kinematics were applied and the resulting contact forces under the prosthesis evolved accordingly, were computed for four subjects with unilateral below-knee amputation walking with a VSF. Results: Model-predicted resultant ground reaction force (GRFR) matched well under trial-specific optimized parameter conditions (mean R2: 0.97, RMSE: 7.7% body weight (BW)) and unoptimized (subject-specific, but not trial-specific) parameter conditions (mean R2: 0.93, RMSE: 12% BW). Simulated anterior-posterior center of pressure demonstrated a mean R2 = 0.64 and RMSE = 14% foot length. Simulated kinematics remained consistent with input data (0.23 deg RMSE, R2 > 0.99) for all conditions. Conclusions: These methods may be useful for simulating gait among individuals with lower-limb loss and predicting GRFR arising from gait with novel VSF prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.

10 February 2025 in Actuators
Verified
Journal Article
Open access
PDF file
KNKieran Marc Nichols
Kieran Marc Nichols
RRRebecca Roembke
Rebecca Roembke
Peter AdamczykPeter Adamczyk
Peter Adamczyk
This paper focused on the implementation method and results of modifying a Raspberry Pi 4 for real-time control of brushless direct-current motors, with application in a semi-active two-axis ankle prosthesis. CANopen over EtherCAT was implemented directly on the Raspberry Pi to synchronize real-time communication between it and the motor controllers. Kinematic algorithms for setting ankle angles of zero to ten degrees in any combination of sagittal and frontal angles were implemented. To achieve reliable motor communication, where the motors continuously move, the distributed clock synchronization of Linux and Motor driver systems needs to have a finely tuned Proportional-Integral compensation and a consistent sampling period. Data collection involved moving the ankle through 33 unique pre-selected ankle configurations nine times. The system allowed for quick movement (mean settling time 0.192 s), reliable synchronization (standard deviation of 4.51 microseconds for sampling period), and precise movement (mean movement error less than 0.2 deg) for ankle angle changes and also a high update rate (250 microseconds sampling period) with modest CPU load (12.48%). This system aims to allow for the prosthesis to move within a single swing phase, enabling it to efficiently adapt to various speeds and terrains, such as walking on slopes, stairs, or around corners.

19 June 2024 in Prosthesis
Verified
Journal Article
Open access
PDF file
MGMichael J. Greene
Michael J. Greene
ISIvan Fischman Ekman Simões
Ivan Fischman Ekman Simões
PLPreston R. Lewis
Preston R. Lewis
KNKieran Marc Nichols
Kieran Marc Nichols
Peter AdamczykPeter Adamczyk
Peter Adamczyk
Frontal plane ankle motion is important for balance in walking but is seldom controlled in robotic prostheses. This article describes the design, control and performance of a semi-active two-degree-of-freedom robotic prosthetic ankle. The mechanism uses a non-backdrivable wedge cam system based on rotating inclined planes, allowing actuation only during swing phases for low power, light weight and compactness. We present details of the mechanism and its kinematic and mechatronic control, and a benchtop investigation of the system’s speed and accuracy in ankle angle control. The two-axis ankle achieves angular reorientation movements spanning ±10 deg in any direction in less than 0.9 s. It achieves a plantarflexion/dorsiflexion error of 0.35 ± 0.27 deg and an inversion/eversion error of 0.29 ± 0.25 deg. Backdriven motion during walking tests is negligible. Strengths of the design include self-locking behavior for low power and simple kinematic control. Two-axis ankle angle control could enable applications such as balance augmentation, turning assistance, and wearable perturbation training.

16 August 2024 in Proceedings of the Human Factors and Ergonomics Society Annual Meeting
Verified
Journal Article
Open access
JHJohn Hayes
John Hayes
BFBlake Fairchild
Blake Fairchild
KNKieran Marc Nichols
Kieran Marc Nichols
JJJeevan Jayasuriya
Jeevan Jayasuriya
RMRanjana K. Mehta
Ranjana K. Mehta
Decrements in sensorimotor performance due to vestibular challenges associated with spaceflight are well characterized, and these impairments pose a significant risk to astronaut safety and mission success. However, the impact of fatigue on this impairment is unknown. We hypothesized that the interaction of fatigue and vestibular impairment would lead to greater-than-additive detriments to static and dynamic balance. Thirteen subjects (9 m/4 f) completed a series of sensorimotor tests (static and dynamic tasks, with and without galvanic vestibular stimulation) before and after a fatigue-induction task. Contrary to the hypothesis, the combination of fatigue and stimulation did not lead to increased impairment in sensorimotor task performance. Subjects displayed improved performance under GVS following the fatigue-induction task during eyes-open conditions, but not during eyes-closed or cognitive dual-task conditions, suggesting that the availability of alternate sensory cues as well as an astronaut’s level of mental workload can impact adaptation to vestibular challenges associated with spaceflight.