Purpose Increasing acquisition efficiency is always a challenge in high-resolution diffusion tensor imaging (DTI), which has low signal-to-noise ratio and is sensitive to reconstruction artifacts. In this study, a parallel imaging (PI) and compressed sensing (CS) combined framework is proposed, which features motion error correction, PI calibration, and sparsity model using inter-image correlation tailored for high-resolution DTI. Theory and Methods The proposed method, named anisotropic sparsity SPIRiT, consists of three steps: (i) motion-induced phase error estimation, (ii) initial CS reconstruction and PI kernel calibration, and (iii) final reconstruction combining PI and CS. Inter-image correlation of diffusion-weighted images are used through anisotropic signals for improved sparsity. A specific implementation based on multishot variable density spiral DTI is used to demonstrate the method. Results The proposed reconstruction method was compared with CG-SENSE, CS-based joint reconstruction, and PI and CS combined methods with L1 and joint sparsity regularization, in brain DTI experiments at acceleration factors of 3 to 5. Both qualitative and quantitative results demonstrated that the proposed method resulted in better preserved image quality and more accurate DTI parameters than other methods. Conclusion The proposed method can accelerate high-resolution DTI acquisition effectively by using the sharable information among different diffusion encoding directions. Magn Reson Med 73:1775–1785, 2015.
Purpose: For multishot diffusion weighted imaging (DWI), one of the challenges is to remove phase variations induced by physiological motion among different shots. In this study, a new method is proposed to iteratively solve the phase errors and DWI images simultaneously, for navigator‐free acquisitions.Theory and Methods: Instead of solving phase errors and the image sequentially in the two‐step parallel imaging, the proposed method, named POCS‐enhanced Inherent Correction of motion‐induced phase Errors (POCS‐ICE), treats both the phase and DWI image as unknowns and solves them simultaneously. Multishot DWI with constant density spiral trajectory served as a specific example. Simulation and in vivo experiments were performed to evaluate the proposed method.Results: POCS‐ICE shows improved image quality in terms of higher SNR and fewer artifacts than the compared method, SENSE+CG. The improvement becomes more conspicuous as the number of shots increases. The convergence behavior of POCS‐ICE was also shown to be more stable.Conclusion: POCS‐ICE can inherently and reliably correct motion‐induced phase errors in navigator‐free multishot DWI, and it is easier to determine the stopping criterion without manual interventions. The improved spatial resolution and image resolvability are beneficial to study of brain microstructures and physiological features for neuroscience. Magn Reson Med 75:169–180, 2016.
Although shown to have a great utility for a wide range of neuroscientific and clinical applications, diffusion-weighted magnetic resonance imaging (dMRI) faces a major challenge of low signal-to-noise ratio (SNR), especially when pushing the spatial resolution for improved delineation of brain's fine structure or increasing the diffusion weighting for increased angular contrast or both. Here, we introduce a comprehensive denoising framework for denoising magnitude dMRI. The framework synergistically combines the variance stabilizing transform (VST) with optimal singular value manipulation. The purpose of VST is to transform the Rician data to Gaussian-like data so that an asymptotically optimal singular value manipulation strategy tailored for Gaussian data can be used. The output of the framework is the estimated underlying diffusion signal for each voxel in the image domain. The usefulness of the proposed framework for denoising magnitude dMRI is demonstrated using both simulation and real-data experiments. Our results show that the proposed denoising framework can significantly improve SNR across the entire brain, leading to substantially enhanced performances for estimating diffusion tensor related indices and for resolving crossing fibers when compared to another competing method. More encouragingly, the proposed method when used to denoise a single average of 7 Tesla Human Connectome Project-style diffusion acquisition provided comparable performances relative to those achievable with ten averages for resolving multiple fiber populations across the brain. As such, the proposed denoising method is expected to have a great utility for high-quality, high-resolution whole-brain dMRI, desirable for many neuroscientific and clinical applications.