Purpose Increasing acquisition efficiency is always a challenge in high-resolution diffusion tensor imaging (DTI), which has low signal-to-noise ratio and is sensitive to reconstruction artifacts. In this study, a parallel imaging (PI) and compressed sensing (CS) combined framework is proposed, which features motion error correction, PI calibration, and sparsity model using inter-image correlation tailored for high-resolution DTI. Theory and Methods The proposed method, named anisotropic sparsity SPIRiT, consists of three steps: (i) motion-induced phase error estimation, (ii) initial CS reconstruction and PI kernel calibration, and (iii) final reconstruction combining PI and CS. Inter-image correlation of diffusion-weighted images are used through anisotropic signals for improved sparsity. A specific implementation based on multishot variable density spiral DTI is used to demonstrate the method. Results The proposed reconstruction method was compared with CG-SENSE, CS-based joint reconstruction, and PI and CS combined methods with L1 and joint sparsity regularization, in brain DTI experiments at acceleration factors of 3 to 5. Both qualitative and quantitative results demonstrated that the proposed method resulted in better preserved image quality and more accurate DTI parameters than other methods. Conclusion The proposed method can accelerate high-resolution DTI acquisition effectively by using the sharable information among different diffusion encoding directions. Magn Reson Med 73:1775–1785, 2015.
Purpose: For multishot diffusion weighted imaging (DWI), one of the challenges is to remove phase variations induced by physiological motion among different shots. In this study, a new method is proposed to iteratively solve the phase errors and DWI images simultaneously, for navigator‐free acquisitions.Theory and Methods: Instead of solving phase errors and the image sequentially in the two‐step parallel imaging, the proposed method, named POCS‐enhanced Inherent Correction of motion‐induced phase Errors (POCS‐ICE), treats both the phase and DWI image as unknowns and solves them simultaneously. Multishot DWI with constant density spiral trajectory served as a specific example. Simulation and in vivo experiments were performed to evaluate the proposed method.Results: POCS‐ICE shows improved image quality in terms of higher SNR and fewer artifacts than the compared method, SENSE+CG. The improvement becomes more conspicuous as the number of shots increases. The convergence behavior of POCS‐ICE was also shown to be more stable.Conclusion: POCS‐ICE can inherently and reliably correct motion‐induced phase errors in navigator‐free multishot DWI, and it is easier to determine the stopping criterion without manual interventions. The improved spatial resolution and image resolvability are beneficial to study of brain microstructures and physiological features for neuroscience. Magn Reson Med 75:169–180, 2016.
A distortion correction method for single-shot EPI was proposed. Point-spread-function encoded EPI (PSF-EPI) images were used as the references to correct traditional EPI images based on deep neural network. The PSF-EPI method can obtain distortion-free echo planar images. In this study, a 2D U-net based network was trained to achieve the distortion correction of single-shot EPI (SS-EPI) images, using PSF-EPI images as targets in the training stage. Anatomical T2W-TSE images were also fed into the network to improve the quality of the results. The applications in diffusion-weighted images were used as examples in this work. The network was trained on data acquired on healthy volunteers and tested on data of both healthy volunteers and patients. The corrected EPI images from the proposed method were also compared with those from field-mapping and top-up based distortion correction methods. Experimental results showed that the proposed method can correct for EPI distortions better than both the field-mapping and top-up based methods, and the results were close to the distortion-free images from PSF-EPI. Additionally, inclusion of T2W-TSE images helped improve distortion correction of the SS-EPI images without contaminating the output noticeably. The experiments with patients and different MRI platforms demonstrated the generalization feasibility of the proposed method preliminarily. Through the correction of diffusion-weighted images, the proposed deep-learning based method was demonstrated to have the feasibility to correct for the distortion of EPI images.