Qipeng Tan

Mr. Qipeng Tan

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2023 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
QTQipeng Tan
Qipeng Tan
BSBin Song
Bin Song
LWLinong Wang
Linong Wang
SWshaocheng Wu
shaocheng Wu
Air‐insulated switchgear plays an important role in distribution network and partial discharge (PD) is one of the common faults in its operation. The method of gas component analysis, which is to detect chemical gas products, is a novel one to discover PD. In order to study the feasibility of the method, the monitoring experiment of characteristic gases, comprising carbon monoxide (CO), nitrogen dioxide (NO 2 ), and ozone (O 3 ), of metal protrusion PD is carried out. This paper conducts the comparative experiments on three main factors affecting PD: voltage, air humidity and degree of protrusion, as well as studies how they affect the formation of characteristic gases. According to the experimental result, higher applied voltage promotes the formation of characteristic gases in the same conditions. In addition, with the increase of humidity from 40% to 75%, the generation of gases is inhibited. Furthermore, when the needle–plate distance is 30 mm, the gas concentration has almost no change within 6 h, which is different from that of 10 mm. In conclusion, the difference in gases concentration reveals the influence of three main factors on the generation of characteristic gases and provides an analytical basis for PD detection by gas composition analysis.

20 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
QTQipeng Tan
Qipeng Tan
TZTiandong Zhang
Tiandong Zhang
SWShaocheng Wu
Shaocheng Wu
JGJiachen Gao
Jiachen Gao
BSBin Song
Bin Song
Partial discharge (PD) is a common phenomenon of insulation aging in air-insulated switchgear and will change the gas composition in the equipment. However, it is still a challenge to diagnose and identify the defect types of PD. This paper conducts enclosed experiments based on gas sensors to obtain the concentration data of the characteristic gases CO, NO2, and O3 under four typical defects. The random forest algorithm with grid search optimization is used for fault identification to explore a method of identifying defect types through gas concentration. The results show that the gases concentration variations do have statistical characteristics, and the RF algorithm can achieve high accuracy in prediction. The combination of a sensor and a machine learning algorithm provides the gas component analysis method a way to diagnose PD in an air-insulated switchgear.