Bin Song

Dr. Bin Song


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
QTQipeng Tan
Qipeng Tan
TZTiandong Zhang
Tiandong Zhang
SWShaocheng Wu
Shaocheng Wu
JGJiachen Gao
Jiachen Gao
BSBin Song
Bin Song
Partial discharge (PD) is a common phenomenon of insulation aging in air-insulated switchgear and will change the gas composition in the equipment. However, it is still a challenge to diagnose and identify the defect types of PD. This paper conducts enclosed experiments based on gas sensors to obtain the concentration data of the characteristic gases CO, NO2, and O3 under four typical defects. The random forest algorithm with grid search optimization is used for fault identification to explore a method of identifying defect types through gas concentration. The results show that the gases concentration variations do have statistical characteristics, and the RF algorithm can achieve high accuracy in prediction. The combination of a sensor and a machine learning algorithm provides the gas component analysis method a way to diagnose PD in an air-insulated switchgear.

20 January 2025 in Sensors
Verified
Journal Article
Open access
PDF file
YAYuhao Ai
Yuhao Ai
BSBin Song
Bin Song
SWshaocheng Wu
shaocheng Wu
YLYongwen Li
Yongwen Li
LLLi Lu
Li Lu
LWLinong Wang
Linong Wang
High-voltage (HV) cables are increasingly used in urban power grids, and their safe operation is critical to grid stability. Previous studies have analyzed various defects, including the open circuit in the sheath loop, the flooding in the cross-bonded link box, and the sheath grounding fault. However, there is a paucity of research on the defect of the reverse direction between the inner core and the outer shield of the coaxial cable. Firstly, this paper performed a theoretical analysis of the sheath current in the reversed-connection state and established a simulation model for verification. The outcomes of the simulation demonstrate that there are significant variations in the amplitudes of the sheath current under different reversed-connection conditions. Consequently, a feature vector was devised based on the amplitude of the sheath current. The support vector machine (SVM) was then applied to diagnose the reversed-connection defects in the HV cable cross-bonded grounding system. The artificial rabbits optimization (ARO) algorithm was adopted to optimize the SVM model, attaining an impressively high diagnostic accuracy rate of 99.35%. The effectiveness and feasibility of the proposed algorithm are confirmed through the analysis and validation of the practical example.

19 February 2025 in Electronics
Verified
Journal Article
Open access
PDF file
LHLong Han
Long Han
BSBin Song
Bin Song
SWshaocheng Wu
shaocheng Wu
DNde yu Nie
de yu Nie
震陈震洋 陈
震洋 陈
LWLinong Wang
Linong Wang
An on-site survey is the primary task of working live in distribution networks. However, the traditional manual on-site survey method is not only not very intuitive but also inefficient. The application of 3D point cloud technology has opened up new avenues for on-site surveys in life working in distribution networks. This paper focused on the application of the Point Transformer V2(PTV2) model in the segmentation of distribution network point clouds. Given its deficiencies in boundary discrimination ability and limited feature extraction ability when processing the point clouds of distribution networks, an improved Non-local Focal Loss-Point Transformer V2 (NF-PTV2) model was proposed. With PTV2 as its core, this model incorporated the Non-Local attention to capturing long-distance feature dependencies, thereby compensating for the PTV2 model’s shortcomings in extracting features of large-scale objects with complex features. Simultaneously, the Focal Loss function was introduced to address the issue of class imbalance and enhance the model’s learning ability for small complex samples. The experimental results demonstrated that the overall accuracy (OA) of this model on the distribution network dataset reached 93.28%, the mean intersection over union (mIoU) reached 81.58%, and the mean accuracy (mAcc) reached 87.21%. In summary, the NF-PTV2 model proposed in this article demonstrated good performance in the point cloud segmentation task of the distribution network and can accurately identify various objects, which, to some extent, overcomes the limitations of the PTV2 model.

26 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
YDYu Dong
Yu Dong
YWYouhang Wang
Youhang Wang
ZLZhiqiang Li
Zhiqiang Li
NLNing Lei
Ning Lei
YWYanchen Wei
Yanchen Wei
BSBin Song
Bin Song
The accurate assessment of the aging state of epoxy resin insulation is critical for the safe operation of cast resin dry-type transformers. This study investigates the evolution of activation energy during thermal aging and its correlation with insulation degradation. Accelerated aging experiments at 150 °C, 170 °C, and 200 °C were conducted, followed by frequency-domain dielectric spectroscopy and Havriliak–Negami (HN) model analysis. An improved method for calculating activation energy, incorporating temperature correction via an HN-based model, is proposed. The evolution of key HN parameters—relaxation strength (Δε), relaxation time (τ), and shape parameters (α, β)—serves as the criterion for identifying the dominant aging mechanism: crosslinking at 150 °C, competition between crosslinking and degradation at 170 °C, and degradation-dominated chain scission at 200 °C. Using 150 °C data as a baseline, the initial activation energy is determined to be 90.03 kJ/mol, increasing to 166.83 kJ/mol at the end of service life. A practical, graded insulation condition indicator based on the rate of change in activation energy (ΔEa) is established, providing clear guidance for maintenance decisions—from routine monitoring (ΔEa ≤ 20%) to prioritized inspection or replacement (ΔEa > 60%). The proposed method offers a non-destructive tool for insulation diagnosis, residual life prediction, and condition-based maintenance of dry-type transformers.

3 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
ZZZisheng Zeng
Zisheng Zeng
BSBin Song
Bin Song
SWshaocheng Wu
shaocheng Wu
YLYongwen Li
Yongwen Li
DNde yu Nie
de yu Nie
LWLinong Wang
Linong Wang
In transmission lines, the discharge characteristics of long air gaps significantly influence the design of external insulation. Existing machine learning models for predicting breakdown voltage are typically limited to single gaps and do not account for the combined effects of complex factors. To address this issue, this paper proposes a novel prediction model based on the Improved Sparrow Search Algorithm-optimized XGBoost (ISSA-XGBoost). Initially, a comprehensive dataset of 46-dimensional electric field eigenvalues was extracted for each gap using finite element simulation software and MATLAB. Subsequently, the model incorporated a comprehensive set of input variables, including electric field eigenvalues, gap distance, waveform and polarity of the switching impulse voltage, temperature, relative humidity, and atmospheric pressure. After training, the ISSA-XGBoost model achieved a Mean Absolute Percentage Error (MAPE) of 7.85%, a Root Mean Squared Error (RMSE) of 56.92, and a Coefficient of Determination (R2) of 0.9938, indicating high prediction accuracy. In addition, the ISSA-XGBoost model was compared with traditional machine learning models and other optimization algorithms. These comparisons further substantiated the efficacy and superiority of the ISSA-XGBoost model. Notably, the model demonstrated exceptional performance in terms of predictive accuracy under extreme atmospheric conditions.

14 March 2026 in Energies
Verified
Journal Article
Open access
PDF file
MWMinhao Wang
Minhao Wang
BSBin Song
Bin Song
The aging of oil-paper insulated transformer components significantly impacts their service life. Accurate health assessment is crucial for predicting failure rates and residual life, which is vital for ensuring operational safety. This paper employs the bathtub curve concept and Weibull distribution to fit collected oil-paper insulated transformer failure rate data, obtaining the failure rate curve. Considering operational environment and load factors, a health index model is established for residual life prediction. By optimizing the weight and bias parameters of the backpropagation (BP) neural network using an adaptive chaotic sequence strategy, a multi-parameter correlated transformer life prediction model is constructed. A cross-validation mechanism is introduced to enhance the model’s generalization ability. Experimental results from training and testing demonstrate that the proposed method achieves higher prediction accuracy, with average errors of 5.36% for annual failure rate and 3.32% for residual life, confirming its effectiveness and applicability in transformer life prediction.