Estíbaliz Ruiz-Ortiz

Dr. Estíbaliz Ruiz-Ortiz

Hospital Clínic de Barcelona, Barcelona, Catalonia, Spain

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GMGuillermo muñoz
Guillermo muñoz
APAlbert Pérez-Isidro
Albert Pérez-Isidro
IPIÑAKI ORTIZ DE LANDAZURI PASCAL
IÑAKI ORTIZ DE LANDAZURI PASCAL
ALAntonio López-Gómez
Antonio López-Gómez
LBLuz Yadira Bravo-Gallego
Luz Yadira Bravo-Gallego
OPOn Behalf Of The 2020 Geai-Sei Workshop Participants
On Behalf Of The 2020 Geai-Sei Workshop Participants
Autoantibody detection is the cornerstone of autoimmune liver diseases (AILD) diagnosis. Standardisation of working algorithms among autoimmunity laboratories, as well as being aware of the sensitivity and specificity of various commercial techniques in daily practice, are still necessary. The aim of this nationwide study is to report the results of the 2020 Autoimmunity Workshop organised by the Autoimmunity Group of the Spanish Society of Immunology and to provide useful information to clinicians and laboratory specialists to improve the management of autoantibody detection in AILD diagnoses. Serum samples from 17 patients with liver diseases were provided by the organisers of the 2020 Autoimmunity Workshop and were subsequently analysed by the 40 participating laboratories. Each laboratory used different techniques for the detection of autoantibodies in each patients’ serum sample, according to their working algorithm. Thus, almost 680 total complete patient reports were obtained, and the number of results from different autoantibody detection techniques was >3000. Up to eight different working algorithms were employed, including indirect immunofluorescence assays (IFA) and antigen-specific techniques (AgST). The IFA of HEp-2 cells was more sensitive than IFA of rat triple tissue for the study of anti-nuclear autoantibodies (ANA) associated with AILD. The IFA of a human neutrophil study for the analysis of anti-neutrophil cytoplasmic autoantibodies was not carried out systemically in all patients, or by all laboratories. AgSTs were the most sensitive methods for the detection of anti-smooth muscle/F-actin, soluble liver antigen, liver cytosol-1, M2-mitochondrial autoantibodies, and ANA associated with primary biliary cholangitis. The main differences in AMA detection were due to patients with autoantibodies against the non-dominant epitope of pyruvate dehydrogenase complex. Given that they are complementary, IFA and AgST should be performed in parallel. If there is high suspicion of AILD, AgST should always be performed.

6 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
APAlbert Pérez-Isidro
Albert Pérez-Isidro
MXMarc Xipell
Marc Xipell
ALArturo Llobell
Arturo Llobell
NMNoemí De Moner
Noemí De Moner
GLGema M. Lledó
Gema M. Lledó
OVOdette Viñas
Odette Viñas
Anti-dsDNA autoantibodies quantification and complement levels are widely used to monitor disease activity in systemic lupus erythematosus (SLE). However, better biomarkers are still needed. We hypothesised whether the dsDNA antibody-secreting B-cells could be a complementary biomarker in disease activity and prognosis of SLE patients. Fifty-two SLE patients were enrolled and followed for up to 12 months. Additionally, 39 controls were included. An activity cut-off (comparing active and non-active patients according to clinical SLEDAI-2K) was established for SLE-ELISpot, chemiluminescence and Crithidia luciliae indirect immunofluorescence tests (≥11.24, ≥374.1 and ≥1, respectively). Assays performances together with complement status were compared regarding major organ involvement at the inclusion and flare-up risk prediction after follow-up. SLE-ELISpot showed the best performance in identifying active patients. High SLE-ELISpot results were associated with haematological involvement and, after follow-up, with an increased hazard ratio for disease flare-up (3.4) and especially renal flare (6.5). Additionally, the combination of hypocomplementemia and high SLE-ELISpot results increased those risks up to 5.2 and 32.9, respectively. SLE-ELISpot offers complementary information to anti-dsDNA autoantibodies to evaluate the risk of a flare-up in the following year. In some cases, adding SLE-ELISpot to the current follow-up protocol for SLE patients can improve clinicians’ personalised care decisions.

24 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
CPCristina Arnaldos Pérez
Cristina Arnaldos Pérez
APAlbert Pérez-Isidro
Albert Pérez-Isidro
UBUma Bolos
Uma Bolos
CDCarmen Domènech
Carmen Domènech
JBJudit Ballús
Judit Ballús
EREstíbaliz Ruiz-Ortiz
Estíbaliz Ruiz-Ortiz
Background: M2-type anti-mitochondrial autoantibodies are considered the hallmark of primary biliary cholangitis and are directed mainly against the E2 subunits of the 2-oxo acid dehydrogenase complex enzymes (PDC, BCOADC and OGDC). The aim of this study was to determine whether a Dot-blot that includes these E2 subunits separately could confirm the results of methods with non-separated subunits in patients with low positive or discordant results between techniques. Methods: Sera of 24 patients with low positive or discordant results and of 10 patients with clear positive results by non-separated subunits methods were analyzed by Dot-blot with separated subunits. Results: Autoantibodies against E2 subunits of PDC, BCOADC or OGDC were detected in all patients, except in one case from the low positive or discordant results group, by Dot-blot with separated subunits. Conclusions: It would be advisable to use methods that include the three E2 subunits, and a Dot-blot with separated subunits could confirm doubtful cases by non-separated assays.

21 June 2023 in Clinical and Experimental Rheumatology
Verified
Journal Article
Closed access
APAlbert Pérez-Isidro
Albert Pérez-Isidro
GLGema M. Lledó-Ibáñez
Gema M. Lledó-Ibáñez
NMNoemí de Moner
Noemí de Moner
MTMaria Torradeflot
Maria Torradeflot
MMMaría José Martínez
María José Martínez
EREstíbaliz Ruiz-Ortiz
Estíbaliz Ruiz-Ortiz
Full Papers; Authors: A. Pérez-Isidro, G.M. Lledó-Ibáñez, N. De Moner, M. Torradeflot, M.J. Martínez, G. Espinosa, M. Tena Campos, M. Grundhuber, O. Viñas, E. Ruiz-Ortiz

23 December 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SBSara Beça
Sara Beça
NBNúria Baños
Núria Baños
MBMaria Borrell Balagué
Maria Borrell Balagué
EREstíbaliz Ruiz-Ortiz
Estíbaliz Ruiz-Ortiz
APAlbert Pérez-Isidro
Albert Pérez-Isidro
Gerard EspinosaGerard Espinosa
Gerard Espinosa
Background: The clinical and laboratory features of patients with non-criteria obstetric antiphospholipid syndrome (NC-OAPS), as well as their pregnancy outcomes and ideal treatment are not clearly determined. The aim of this study is to describe the characteristics and outcomes of pregnancies in NC-OAPS and compare them with an obstetric APS (OAPS) cohort. Methods: This is a retrospective study conducted on a cohort of women referred to a high-risk obstetric unit of a tertiary hospital. Women that were classified as having OAPS or NC-OAPS were included and compared in terms of clinical and laboratory characteristics, management, and subsequent pregnancy outcomes. Results: We identified 107 women with 143 pregnancies, 91 with NC-OAPS and 16 with OAPS. There were no differences in demographic features between both groups. Women with NC-OAPS were more likely to have recurrent implantation failure and were predominantly positive for a single antiphospholipid antibody (aPL) subtype. Both groups were treated similarly (low dose aspirin plus low molecular weight heparin in 87.4% of NC-OAPS and 83.3% of OAPS, p > 0.05). Live birth rate (82.4% and 75.0%, respectively, p > 0.05) and adverse pregnancy outcomes (31.6% vs. 37.5%, p > 0.05) in subsequent pregnancies during follow-up were also similar between groups. Conclusions: This study revealed differences in the previous pregnancy morbidity and aPL profiles in women with NC-OAPS and OAPS, although the therapeutic approach and the outcomes of subsequent pregnancies were similar in both groups.

6 November 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
SBSara Beça
Sara Beça
NBNúria Baños
Núria Baños
MBMaria Borrell Balagué
Maria Borrell Balagué
EREstíbaliz Ruiz-Ortiz
Estíbaliz Ruiz-Ortiz
APAlbert Pérez-Isidro
Albert Pérez-Isidro
Gerard EspinosaGerard Espinosa
Gerard Espinosa
Background: The clinical and laboratory features of patients with non-criteria obstetric antiphospholipid syndrome (NC-OAPS), as well as their pregnancy outcomes and ideal treatment are not clearly determined. The aim of this study is to describe the characteristics and outcomes of pregnancies in NC-OAPS and compare them with an obstetric APS (OAPS) cohort. Methods: Retrospective study conducted in a cohort of women referred to a high-risk obstetric unit of a tertiary hospital. Women that were classified as having OAPS or NC-OAPS were included and compared in terms of clinical and laboratory characteristics, management, and subsequent pregnancy outcomes. Results: We identified 107 women with 143 pregnancies, 91 with NC-OAPS and 16 with OAPS. There were no differences in demographic features between both groups. Women with NC-OAPS were more likely to have recurrent implantation failure and were predominantly positive for a single antiphospholipid antibody (aPL) subtype. Both groups were treated similarly (low dose aspirin plus low molecular weight heparin in 87.4% of NC-OAPS and 83.3% of OAPS, p>0.05). Live birth rate (82.4% and 75.0%, respectively, p>0.05) and adverse pregnancy outcomes (31.6% vs 37.5%, p>0.05) in subsequent pregnancies during follow-up were also similar between groups. Conclusions: This study revealed differences in the previous pregnancy morbidity and aPL profiles in women with NC-OAPS and OAPS, although the therapeutic approach and the outcomes of subsequent pregnancies were similar in both groups.