One of the important factors determining the biochemical processes in bioreactors is the quality of the wastewater inflow to the wastewater treatment plant (WWTP). Information on the quality of wastewater, sufficiently in advance, makes it possible to properly select bioreactor settings to obtain optimal process conditions. This paper presents the use of classification models to predict the variability of wastewater quality at the inflow to wastewater treatment plants, the values of which depend only on the amount of inflowing wastewater. The methodology of an expert system to predict selected indicators of wastewater quality at the inflow to the treatment plant (biochemical oxygen demand, chemical oxygen demand, total suspended solids, and ammonium nitrogen) on the example of a selected WWTP—Sitkówka Nowiny, was presented. In the considered system concept, a division of the values of measured wastewater quality indices into lower (reduced values of indicators in relation to average), average (typical and most common values), and upper (increased values) were adopted. On the basis of the calculations performed, it was found that the values of the selected wastewater quality indicators can be identified with sufficient accuracy by means of the determined statistical models based on the support vector machines and boosted trees methods.
Photovoltaic (PV) modules undergo comprehensive testing to validate their electrical and thermal properties prior to market entry. These evaluations consist of durability and efficiency tests performed under realistic outdoor conditions with natural climatic influences, as well as in controlled laboratory settings. The overall performance of PV cells is affected by several factors, including solar irradiance, operating temperature, installation site parameters, prevailing weather, and shading effects. In the presented study, three distinct PV modules were analyzed using a sophisticated large-scale steady-state solar simulator. The current–voltage (I-V) characteristics of each module were precisely measured and subsequently scrutinized. To augment the analysis, a three-layer artificial neural network, specifically the multilayer perceptron (MLP), was developed. The experimental measurements, along with the outputs derived from the MLP model, served as the foundation for a comprehensive global sensitivity analysis (GSA). The experimental results revealed variances between the manufacturer’s declared values and those recorded during testing. The first module achieved a maximum power point that exceeded the manufacturer’s specification. Conversely, the second and third modules delivered power values corresponding to only 85–87% and 95–98% of their stated capacities, respectively. The global sensitivity analysis further indicated that while certain parameters, such as efficiency and the ratio of Voc/V, played a dominant role in influencing the power-voltage relationship, another parameter, U, exhibited a comparatively minor effect. These results highlight the significant potential of integrating machine learning techniques into the performance evaluation and predictive analysis of photovoltaic modules.
An innovative method was proposed to facilitate the analyses of meteorological conditions and selected air pollution indices’ influence on visibility, air quality index and mortality. The constructed calculation algorithm is dedicated to simulating the visibility in a single episode, first of all. It was derived after applying logistic regression methodology. It should be stressed that eight visibility thresholds (Vis) were adopted in order to build proper classification models with a number of relevant advantages. At first, there exists the possibility to analyze the impact of independent variables on visibility with the consideration of its’ real variability. Secondly, through the application of the Monte Carlo method and the assumed classification algorithms, it was made possible to model the number of days during a precipitation and no-precipitation periods in a yearly cycle, on which the visibility ranged practically: Vis < 8; Vis = 8–12 km, Vis = 12–16 km, Vis = 16–20 km, Vis = 20–24 km, Vis = 24–28 km, Vis = 28–32 km, Vis > 32 km. The derived algorithm proved a particular role of precipitation and no-precipitation periods in shaping the air visibility phenomena. Higher visibility values and a lower number of days with increased visibility were found for the precipitation period contrary to no-precipitation one. The air quality index was lower for precipitation days, and moreover, strong, non-linear relationships were found between mortality and visibility, considering precipitation and seasonality effects.
The paper focuses on important elements i.e. appropriate lighting conditions at workstations and the assessment of subjective productivity as a function of indoor environmental parameters, using the example of students in the intelligent building “Energis” at the Kielce University of Technology, where an experimental study was performed. A group of volunteers completed questionnaires about their subjective feelings related to lighting conditions in lecture halls at different times of the year and assessed their current productivity. Accurate physical measurements of illuminance with a high accuracy microclimate meter were carried out. Comparing the statements of the room users with the measurements allowed conclusions to be drawn about the conditions provided in the intelligent building related to lighting, as well as the impact of the working environment on the productivity of the room users. The findings provide valued information on lighting conditions in modern, intelligent buildings, which are becoming increasingly common around the world, for various purposes such as office, educational and other public buildings, so that appropriate indoor conditions can be used to optimise productivity and efficiency.
In the paper the measurements of thermal comfort in the modern smart building “Energis” have been presented together with their analysis. The data have been obtained in the spring and the analyses of indoor air parameters as well as subjective responses of the volunteers have been conducted. Based on the performed studies it has been concluded that the people felt fine in the considered room (pleasantly warm, cool and comfortable) and described their feelings as acceptable and comfortable.