Dr. Engr. Ahmed Muddassir Muddassir Khan

Prof. Dr. Engr. Ahmed Muddassir Muddassir Khan

Indus University Karachi Sindh

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Abdul GhaffarAbdul Ghaffar
Abdul Ghaffar
SNSanku Niu
Sanku Niu
MMmujahid Mehdi
mujahid Mehdi
SHSadam Hussain
Sadam Hussain
DKDr. Engr. Ahmed Muddassir Muddassir Khan
Dr. Engr. Ahmed Muddassir Muddassir Khan
SASalamat Ali
Salamat Ali
This study introduces a cost-effective solution and sensor arrays for the multipoint liquid-level measuring sensor based on an intensity modulation technique. The sensor structure is based on the twisting of two fibers and creates cascading to achieve a multipoint detection. Three sensors are fabricated on a single illuminated polymer optical fiber. The twisting creates side-coupling between two fibers, and the coupled power is attenuated when liquid emerges in the coupled region. Each sensor has its own output source, which is connected to the power meter. When the liquid-level increases, the coupled power is continuously decreased. The multipoint liquid-level sensor is theoretical and experimentally tested. The experimental results show that sensors have a good response and linearity. The sensors are able to measure the liquid-level up to 12 cm and have a sensitivity of about 0.2726 μW/cm, 0.1715 μW/cm, and 0.1281 μW/cm, respectively. The different flow rate (50 mL/min–300 mL/min) is also analyzed to validate the dynamic response of the sensor. The sensor demonstrates a high sensitivity and resolution in the liquid-level detection. Meanwhile, the liquid-level variation is individually and simultaneously measured. The system does not require any decoupling technique as the system relies on a single LED source, and the coupled power is individually measured from each power meter. The system represents a significant advancement in precise liquid-level sensing technology, as the system has advantages of a flexible, durable, cost-effective, and active response with respect to changes in the liquid-level.

6 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AAAdeel Ahmed
Adeel Ahmed
Danish KhanDanish Khan
Danish Khan
DKDr. Engr. Ahmed Muddassir Muddassir Khan
Dr. Engr. Ahmed Muddassir Muddassir Khan
MMMuhammad Umair Mustafa
Muhammad Umair Mustafa
MPManoj Kumar Panjwani
Manoj Kumar Panjwani
JEJoshua Edokpayi
Joshua Edokpayi
With the recent development in power electronic devices, HVDC (High Voltage Direct Current) systems have been recognized as the most prominent solution to transmit electric power economically. Today, several HVDC projects have been implemented physically. The conventional HVDC systems use grid commutation converters, and its commutation relies on an AC system for the provision of voltage. Due to this reason, there are possibilities of commutation failure during fault. Furthermore, once the DC (Direct Current) system power is interrupted momentarily, the reversal of work power is likely to cause transient over-voltage, which will endanger the safety of power grid operation. Hence, it is necessary to study the commutation failure and transient over-voltage issues. To tackle the above issues, in this paper, the dynamic and transient characteristics of Pakistan’s first HVDC project, i.e., the Matiari–Lahore ±660 kV transmission line has been analyzed in an electromagnetic transient model of PSCAD/EMTDC. Based on the characteristics of the DC and the off-angle after the failure, a new control strategy has been proposed. The HVDC system along with its proposed control strategy has been tested under various operating conditions. The proposed controller increases the speed of fault detection, reduces the drop of AC voltage and DC and suppresses the commutation failure probability of LCC-HVDC (line commutated converter- high voltage direct current).