The metallic layers are an essential part of MEMS (micro electromechanical system) devices, and their deposition process must be accurately controlled; this may lead to difficulties as there are many input parameters for such a process. This research focuses on the input parameters’ effects on the Ni pulse-reverse electroplating. A neural network was constructed to characterize the pulse-reverse nickel electroforming process parameters. The sample training has accurately established the mapping relationship between input and output parameters. The nickel layer thickness and surface roughness prediction in the pulse-reverse electroplating process was realized and verified by experimental tests with a test error of 3.3%. Then, the effect of direct and reverse current density, deposition time, structure width, and stirring speed as input parameters on the thickness and surface roughness are investigated. Finally, a novel 4D diagram has been developed to derive the optimal values of direct and reverse current density relative to thickness, surface roughness, and deposition time. This diagram can help researchers and industries find suitable parameters to achieve the desired deposited Ni layer’s properties.
The development of microgrippers requires accurate control of force and position for the grasping mechanisms in micromanipulation. This controllability ensures the safe transfer of sensitive micro-objects, such as living cells. The design of microgrippers is often limited by the dimensions and adaptability of the micro-objects being manipulated. Therefore, microgrippers should be customized for each micro-object. Additionally, complex sensor mechanisms are required to control the gripping force. This study introduces a novel design of a four-arm MEMS electrothermal microgripper intended for versatile micromanipulation purposes. The microgripper design procedure is compatible with a list of constraints, including biological and microfabrication constraints. The jaw form is designed to manipulate micro-objects with a wide range of dimensions (1 to 360 μm). Furthermore, a novel approach is presented here to control the force threshold of gripping without a sensor during manipulation. The proposed solution involves using structure stiffening to control the force and prevent damage to micro-objects. GA and analytical models (transient behaviour of structure) are used to satisfy the long list of constraints. The device is fabricated through UV-LIGA, utilizing nickel and copper as the structural and sacrificial layer. The experimental and simulation results demonstrate that the microgripper can achieve a 60 μm jaw displacement at a voltage of 0.329V. The gripping arms can provide a force of 15 to 450 μN for the handling of micro-objects. The maximum gripper temperature of 98 °C makes it suitable for biological applications. The innovative form and systematic design of the microgripper enable its adaptability for various applications.
The sacrificial layer is a key component for the fabrication of a released structure in the MEMS sensors and actuators. Wet etching is a practical microfabrication process that minimizes costs compared to dry etching. Since the sacrificial layer exists between the structural layer and the substrate, characterization of the etching process is unavailable to observe and evaluate directly. This research, for the first time, presents a methodology for monitoring sacrificial layer removal. It takes advantage of using a transparent substrate (during process development) to observe the removal process from the backside. This method can be used as a separate test during surface micromachining to monitor and optimize the release process of the MEMS device. To evaluate the efficiency of the method, the copper sacrificial layer was selected. The removal process was investigated for typical structures used in MEMS sensors and actuators including the etch-holes, the cantilever beams, comb fingers, and the pads. The experimental test showed the removal of the sacrificial layer, the non-uniformity of the etching, and all the veritable chemical reactions and phenomena under the structural layer. In addition, the etch-rate were obtained in the order of 0.35–5.5 μm min−1 for various structural features. The procedure developed in this research is an approach to the process monitoring of the sacrificial layer removal. Therefore, it can be used to organize the quality control in the released structures of MEMS and optimization in batch processing. This method can be adopted for non-metallic sacrificial layers and dry etching as well.
This paper presents the design, sim-ulation, and fabrication of a novel dual-range MEMS capacitive accelerometer that utilizes a dual-flexural suspension system for enhanced dynamic perfor-mance. The device inte-grates two sensing modes—low-g and high-g—within a unified archi-tecture to achieve both high sensitivity and wide dynamic range. Through systematic design optimization using COMSOL Multiphysics, the proposed accelerometer exhibits a high degree of linearity and stability across both operational ranges. Based on UV-Liga technology, the fabrication process is detailed alongside the results of the fabricated sensor's structure. Experimental results demon-strate successful mode switching with a sensitivity of 0.9 mV/g and 0.2 mV/g for low-g and high-g modes, respectively, validating the viability of the dual-mode concept for advanced inertial sensing applications such as navigation and structural monitoring.
14 September 2026 in Advanced Functional Materials
Recent advances in materials science and rehabilitation robotics have shown strong potential for active prosthetics capable of interacting with tools and objects. The key requirement for future active prosthetics is realistic tactile feedback. Despite significant progress, conventional tactile sensors cannot fully reproduce human‐like perception, likely due to their fundamentally different sensing mechanisms. This study presents a skin‐inspired artificial mechanoreceptor composed of microfluidic channels filled with NaCl electrolyte and embedded within soft elastomeric membranes. Intrinsic surface chemistry induces a non‐uniform ionic distribution inside the channels. Mechanical stimulation disturbs this distribution, leading to changes in electrical potential. Unlike traditional sensors based on purely electronic transduction, the proposed self‐powered mechanoreceptor operates through ionic interactions similar to those in biological mechanoreceptors. The generated signal exhibits temporal features such as overshoot and undershoot, analogous to neural depolarization and repolarization. Frequency analysis shows a dominant peak near 440 Hz, consistent with the operating range of Pacinian mechanoreceptors. The output potential depends strongly on ionic concentration, with an optimal value around 5 mM NaCl. The proposed mechanoreceptor offers strong potential for improved neural compatibility by ionically modulating the electrical potential in the medium and is expected to provide more realistic tactile perception in future prosthetic limbs.
Soft pneumatic actuators are essential components in bioinspired and wearable systems, where flexibility, adaptability, and safe human interaction are required. However, most pneumatic designs rely on bulky chambers that limit miniaturization and prevent implementation in thin films actuation. Therefore, achieving efficient planar pneumatic actuation remains challenging. Here, a novel actuator is introduced called soft interconnected network (SIN) actuator, featuring a two‐dimensional network of interconnected microchannels embedded within an asymmetric bilayer polydimethylsiloxane (PDMS). Upon pressurization, localized strain gradients drive dual‐curvature out‐of‐plane deformation, forming a dome‐shaped motion. This skin‐like actuator exhibits large, reversible displacement and blocking force despite an overall thickness of only 2 mm. The conducted systematic geometric study shows how channel height, width, pattern resolution, and layer thickness govern actuation performance. The optimized design can achieve a large peak displacement of 30 mm under moderate pressure levels. Finally, the proposed soft actuator is implemented in a bio‐inspired prototype to mimic smooth, cyclic expansion–contraction behavior of a jellyfish bell, confirming its high potential for utilization in future bio‐inspired robots as an artificial muscle. This work establishes a generalizable platform for planar pneumatic actuation and paves the way toward next‐generation artificial skins, soft muscles, and bioinspired robots capable of 2D shell deformation.