Anna-Maria Raita-Hakola

Mrs. Anna-Maria Raita-Hakola

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
VLVivian Lindholm
Vivian Lindholm
ARAnna-Maria Raita-Hakola
Anna-Maria Raita-Hakola
LALeevi Annala
Leevi Annala
MSMari Salmivuori
Mari Salmivuori
LJLeila Jeskanen
Leila Jeskanen
ARAnnamari Ranki
Annamari Ranki
Several optical imaging techniques have been developed to ease the burden of skin cancer disease on our health care system. Hyperspectral images can be used to identify biological tissues by their diffuse reflected spectra. In this second part of a three-phase pilot study, we used a novel hand-held SICSURFIS Spectral Imager with an adaptable field of view and target-wise selectable wavelength channels to provide detailed spectral and spatial data for lesions on complex surfaces. The hyperspectral images (33 wavelengths, 477–891 nm) provided photometric data through individually controlled illumination modules, enabling convolutional networks to utilise spectral, spatial, and skin-surface models for the analyses. In total, 42 lesions were studied: 7 melanomas, 13 pigmented and 7 intradermal nevi, 10 basal cell carcinomas, and 5 squamous cell carcinomas. All lesions were excised for histological analyses. A pixel-wise analysis provided map-like images and classified pigmented lesions with a sensitivity of 87% and a specificity of 93%, and 79% and 91%, respectively, for non-pigmented lesions. A majority voting analysis, which provided the most probable lesion diagnosis, diagnosed 41 of 42 lesions correctly. This pilot study indicates that our non-invasive hyperspectral imaging system, which involves shape and depth data analysed by convolutional neural networks, is feasible for differentiating between malignant and benign pigmented and non-pigmented skin tumours, even on complex skin surfaces.

9 May 2024 in Journal of Applied Phycology
Verified
Journal Article
Open access
PDF file
SPSalli Pääkkönen
Salli Pääkkönen
IPIlkka Pölönen
Ilkka Pölönen
ARAnna-Maria Raita-Hakola
Anna-Maria Raita-Hakola
MCMariana Carneiro
Mariana Carneiro
HCHelena Cardoso
Helena Cardoso
PSPauliina Salmi
Pauliina Salmi
High expectations are placed on microalgae as a sustainable source of valuable biomolecules. Robust methods to control microalgae cultivation processes are needed to enhance their efficiency and, thereafter, increase the profitability of microalgae-based products. To meet this need, a non-invasive monitoring method based on a hyperspectral imager was developed for laboratory scale and afterwards tested on industrial scale cultivations. In the laboratory experiments, reference data for microalgal biomass concentration was gathered to construct 1) a vegetation index-based linear regression model and 2) a one-dimensional convolutional neural network model to resolve microalgae biomass concentration from the spectral images. The two modelling approaches were compared. The mean absolute percentage error (MAPE) for the index-based model was 15–24%, with the standard deviation (SD) of 13-18 for the different species. MAPE for the convolutional neural network was 11–26% (SD = 10–22). Both models predicted the biomass well. The convolutional neural network could also classify the monocultures of green algae by species (accuracy of 97–99%). The index-based model was fast to construct and easy to interpret. The index-based monitoring was also tested in an industrial setup demonstrating a promising ability to retrieve microalgae-biomass-based signals in different cultivation systems.

29 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ARAnna-Maria Raita-Hakola
Anna-Maria Raita-Hakola
LALeevi Annala
Leevi Annala
VLVivian Lindholm
Vivian Lindholm
RTRoberts Trops
Roberts Trops
ANAntti Näsilä
Antti Näsilä
IPIlkka Pölönen
Ilkka Pölönen
Hyperspectral imaging (HSI) applications for biomedical imaging and dermatological applications have been recently under research interest. Medical HSI applications are non-invasive methods with high spatial and spectral resolution. HS imaging can be used to delineate malignant tumours, detect invasions, and classify lesion types. Typical challenges of these applications relate to complex skin surfaces, leaving some skin areas unreachable. In this study, we introduce a novel spectral imaging concept and conduct a clinical pre-test, the findings of which can be used to develop the concept towards a clinical application. The SICSURFIS spectral imager concept combines a piezo-actuated Fabry–Pérot interferometer (FPI) based hyperspectral imager, a specially designed LED module and several sizes of stray light protection cones for reaching and adapting to the complex skin surfaces. The imager is designed for the needs of photometric stereo imaging for providing the skin surface models (3D) for each captured wavelength. The captured HS images contained 33 selected wavelengths (ranging from 477 nm to 891 nm), which were captured simultaneously with accordingly selected LEDs and three specific angles of light. The pre-test results show that the data collected with the new SICSURFIS imager enable the use of the spectral and spatial domains with surface model information. The imager can reach complex skin surfaces. Healthy skin, basal cell carcinomas and intradermal nevi lesions were classified and delineated pixel-wise with promising results, but further studies are needed. The results were obtained with a convolutional neural network.

10 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SRSamuli Rahkonen
Samuli Rahkonen
LLLeevi Lind
Leevi Lind
ARAnna-Maria Raita-Hakola
Anna-Maria Raita-Hakola
SKSampsa Kiiskinen
Sampsa Kiiskinen
IPIlkka Pölönen
Ilkka Pölönen
Hyperspectral imaging and distance data have previously been used in aerial, forestry, agricultural, and medical imaging applications. Extracting meaningful information from a combination of different imaging modalities is difficult, as the image sensor fusion requires knowing the optical properties of the sensors, selecting the right optics and finding the sensors’ mutual reference frame through calibration. In this research we demonstrate a method for fusing data from Fabry–Perot interferometer hyperspectral camera and a Kinect V2 time-of-flight depth sensing camera. We created an experimental application to demonstrate utilizing the depth augmented hyperspectral data to measure emission angle dependent reflectance from a multi-view inferred point cloud. We determined the intrinsic and extrinsic camera parameters through calibration, used global and local registration algorithms to combine point clouds from different viewpoints, created a dense point cloud and determined the angle dependent reflectances from it. The method could successfully combine the 3D point cloud data and hyperspectral data from different viewpoints of a reference colorchecker board. The point cloud registrations gained 0.29–0.36 fitness for inlier point correspondences and RMSE was approx. 2, which refers a quite reliable registration result. The RMSE of the measured reflectances between the front view and side views of the targets varied between 0.01 and 0.05 on average and the spectral angle between 1.5 and 3.2 degrees. The results suggest that changing emission angle has very small effect on the surface reflectance intensity and spectrum shapes, which was expected with the used colorchecker.

29 October 2025 in ISPRS Annals of the Photogrammetry, Remote Sensing and Spatial Information Sciences
Verified
Journal Article
Open access
PDF file
JJJukka Joutsalainen
Jukka Joutsalainen
MVMaxim Vitikainen
Maxim Vitikainen
JLJuuso Lehrbäck
Juuso Lehrbäck
AGAlexander Goldhill
Alexander Goldhill
ARAnna-Maria Raita-Hakola
Anna-Maria Raita-Hakola
The research field of small, lightweight object-detection models that are capable of real-time monitoring, particularly for the detection of wildfires, is highly popular. However, a quick overview of the literature reveals that while most research suggests lightweight models, it does not report results from tests conducted on platforms with limited computational power or frameworks that might enable practical applicability of the techniques. This leaves the algorithms without real-time usability tests. This study addresses the research gap, aiming to provide a robust and low-cost framework (Fireframe) for edge device deployment for wildfire smoke detection. Fireframe combines hardware (Raspberry 5 computer and Basler machine vision camera) and a trained object detection model with tasks that are performed in an operational loop (main thread). It can simultaneously record a live stream, analyze whether wildfire smoke is present, and display the findings. Fireframe is tested using two lightweight models (YOLOv10 and MobileNetV3), and the findings confirm its suitability for simulations and real-life action.

17 July 2025 in Sensing and Imaging
Verified
Journal Article
Open access
PDF file
LLLeevi Lind
Leevi Lind
FRFelipe Reis Campanha Ribeiro
Felipe Reis Campanha Ribeiro
HSHeikki Saari
Heikki Saari
HOHarri Ojanen
Harri Ojanen
CHChrister Holmlund
Christer Holmlund
IPIlkka Pölönen
Ilkka Pölönen
The calibration stability of miniature spectral imagers based on a piezolectrically tunable Fabry-Perot interferometer (FPI) has not been previously examined in long-term use. These instruments are increasingly launched to space, for example on the Kuva Space’s Hyperfield-fleet of Earth observation satellites and with the ESA Hera asteroid mission. Difficulty of re-calibration in a space environment means that prior knowledge of possible calibration drift is invaluable. In this study, we examined the performance of an FPI imager that was used for nine years in a hospital environment. We analyzed images gathered during the use of the imager, looking for systematic errors. A degree of drift in the results was found, but we could not determine whether it was caused by imager degradation or changes in the measurement setup. We also performed new characterization measurements for the imager. Based on the measurement results, the FPI control circuits’ response to setpoint values sent to them appears to have changed. This error could be caused by a leak in the hermetic seal around the FPI. Repeated measurements showed similar results, indicating that the imager performance is consistent.