Myung Hye Cho

Mrs. Myung Hye Cho


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MMohamed Eldib
Mohamed Eldib
MHMOHAMED HEGAZY
MOHAMED HEGAZY
YMYang Ji Mun
Yang Ji Mun
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT). In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D) mean vector, and we then compute the 1D correction vector by taking inverse of the mean vector. We multiply the correction vector with the sinogram row by row over all view angles. In the third step, we apply a Gaussian filter on the difference image between the original CT image and the corrected CT image obtained in the previous step. The filtered difference image is added to the corrected CT image to compensate the possible contrast anomaly that may appear due to the contrast change in the sinogram after removing stripe artifacts. We applied the proposed method to the projection data acquired by two flat-panel detectors (FPDs) and a silicon-based photon-counting X-ray detector (PCXD). Micro-CT imaging experiments of phantoms and a small animal have shown that the proposed method can greatly reduce ring artifacts regardless of detector types. Despite the great reduction of ring artifacts, the proposed method does not compromise the original spatial resolution and contrast.

23 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
Metal artifacts in dental computed tomography (CT) images, caused by highly X-ray absorbing objects, such as dental implants or crowns, often more severely compromise image readability than in medical CT images. Since lower tube voltages are used for dental CTs in spite of the more frequent presence of metallic objects in the patient, metal artifacts appear more severely in dental CT images, and the artifacts often persist even after metal artifact correction. The direct sinogram correction (DSC) method, which directly corrects the sinogram using the mapping function derived by minimizing the sinogram inconsistency, works well in the case of mild metal artifacts, but it often fails to correct severe metal artifacts. We propose a modified DSC method to reduce severe metal artifacts, and we have tested it on human dental images. We first segment the metallic objects in the CT image, and then we forward-project the segmented metal mask to identify the metal traces in the projection data with computing the metal path length for the rays penetrating the metal mask. In the sinogram correction with the DSC mapping function, we apply the weighting proportional to the metal path length. We have applied the proposed method to the phantom and patient images taken at the X-ray tube voltage of 90 kVp. We observed that the proposed method outperforms the original DSC method when metal artifacts were severe. However, we need further extensive studies to verify the proposed method for various CT scan conditions with many more patient images.

7 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MCMyung Hye Cho
Myung Hye Cho
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
Cone-beam dental CT can provide high-precision 3D images of the teeth and surrounding bones. From the 3D CT images, 3D models, also called digital impressions, can be computed for CAD/CAM-based fabrication of dental restorations or orthodontic devices. However, the cone-beam angle-dependent artifacts, mostly caused by the incompleteness of the projection data acquired in the circular cone-beam scan geometry, can induce significant errors in the 3D models. Using a micro-CT, we acquired CT projection data of plaster cast models at several different cone-beam angles, and we investigated the dependency of the model errors on the cone-beam angle in comparison with the reference models obtained from the optical scanning of the plaster models. For the 3D CT image reconstruction, we used the conventional Feldkamp algorithm and the combined half-scan image reconstruction algorithm to investigate the dependency of the model errors on the image reconstruction algorithm. We analyzed the mean of positive deviations and the mean of negative deviations of the surface points on the CT-image-derived 3D models from the reference model, and we compared them between the two image reconstruction algorithms. It has been found that the model error increases as the cone-beam angle increases in both algorithms. However, the model errors are smaller in the combined half-scan image reconstruction when the cone-beam angle is as large as 10 degrees.

21 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
Dental 3D modeling plays a pivotal role in digital dentistry, offering precise tools for treatment planning, implant placement, and prosthesis customization. Traditional methods rely on physical plaster casts, which pose challenges in storage, accessibility, and accuracy, fueling interest in digitization using 3D computed tomography (CT) imaging. We introduce a method that can reduce both artifacts simultaneously. To validate the proposed method, we carried out CT scan experiments using plaster dental casts created from dental impressions. After the artifact correction, the CT image quality was greatly improved in terms of image uniformity, contrast-to-noise ratio (CNR), and edge sharpness. We examined the correction effects on the accuracy of the 3D models generated from the CT images. As referenced to the 3D models derived from the optical scan data, the root mean square (RMS) errors were reduced by 8.8~71.7% for three dental casts of different sizes and shapes. Our method offers a solution to challenges posed by artifacts in CT scanning of plaster dental casts, leading to enhanced 3D model accuracy. This advancement holds promise for dental professionals seeking precise digital modeling for diverse applications in dentistry.