MOHAMED HEGAZY

Mr. MOHAMED HEGAZY


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2019 in Biomedical Engineering Letters
Verified
Journal Article
Closed access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee

30 January 2017 in Sensors
Verified
Journal Article
Open access
PDF file
MMohamed Eldib
Mohamed Eldib
MHMOHAMED HEGAZY
MOHAMED HEGAZY
YMYang Ji Mun
Yang Ji Mun
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
We introduce an efficient ring artifact correction method for a cone-beam computed tomography (CT). In the first step, we correct the defective pixels whose values are close to zero or saturated in the projection domain. In the second step, we compute the mean value at each detector element along the view angle in the sinogram to obtain the one-dimensional (1D) mean vector, and we then compute the 1D correction vector by taking inverse of the mean vector. We multiply the correction vector with the sinogram row by row over all view angles. In the third step, we apply a Gaussian filter on the difference image between the original CT image and the corrected CT image obtained in the previous step. The filtered difference image is added to the corrected CT image to compensate the possible contrast anomaly that may appear due to the contrast change in the sinogram after removing stripe artifacts. We applied the proposed method to the projection data acquired by two flat-panel detectors (FPDs) and a silicon-based photon-counting X-ray detector (PCXD). Micro-CT imaging experiments of phantoms and a small animal have shown that the proposed method can greatly reduce ring artifacts regardless of detector types. Despite the great reduction of ring artifacts, the proposed method does not compromise the original spatial resolution and contrast.

27 August 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMyung Hye Cho
Myung Hye Cho
SLSoo Yeol Lee
Soo Yeol Lee
The successful development of the image denoising techniques for low-dose computed tomography (LDCT) was largely owing to the public-domain availability of spatially-aligned high- and low-dose CT image pairs. Even though low-dose CT scans are also highly desired in dental imaging, public-domain databases of dental CT image pairs have not been established yet. In this paper, we propose a dental CT image denoising method based on the transfer learning of a generative adversarial network (GAN) from the public-domain CT images. We trained a generative adversarial network with the Wasserstein loss function (WGAN) using 5,100 high- and low-dose medical CT image pairs of human chest and abdomen. For the generative network of GAN, we used the U-net structure of five stages to exploit its high computational efficiency. After training the proposed network, named U-WGAN, we fine-tuned the network with 3,006 dental CT image pairs of two different human skull phantoms. For the high- and low-dose scans of the phantoms, we set the tube current of the dental CT to 10 mA and 4 mA, respectively, with the tube voltage set to 90 kVp in both scans. We applied the trained network to denoising of low-dose dental CT images of dental phantoms and adult humans. The U-net processed images showed over-smoothing effects even though U-net had a good performance in the quantitative metrics. U-WGAN showed similar denoising performance to WGAN, but it reduced the computation time of WGAN by a factor of 10. The fine-tuning procedure in the transfer learning scheme enhanced the network performance in terms of the quantitative metrics, and it also improved visual appearance of the processed images. Even though the number of fine-tuning images was very limited in this study, we think the transfer learning scheme can be a good option for developing deep learning networks for dental CT image denoising.

2 January 2018 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MEMohamed Elsayed Eldib
Mohamed Elsayed Eldib
DHDaniel Hernandez
Daniel Hernandez
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee

23 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMyung Hye Cho
Myung Hye Cho
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
Metal artifacts in dental computed tomography (CT) images, caused by highly X-ray absorbing objects, such as dental implants or crowns, often more severely compromise image readability than in medical CT images. Since lower tube voltages are used for dental CTs in spite of the more frequent presence of metallic objects in the patient, metal artifacts appear more severely in dental CT images, and the artifacts often persist even after metal artifact correction. The direct sinogram correction (DSC) method, which directly corrects the sinogram using the mapping function derived by minimizing the sinogram inconsistency, works well in the case of mild metal artifacts, but it often fails to correct severe metal artifacts. We propose a modified DSC method to reduce severe metal artifacts, and we have tested it on human dental images. We first segment the metallic objects in the CT image, and then we forward-project the segmented metal mask to identify the metal traces in the projection data with computing the metal path length for the rays penetrating the metal mask. In the sinogram correction with the DSC mapping function, we apply the weighting proportional to the metal path length. We have applied the proposed method to the phantom and patient images taken at the X-ray tube voltage of 90 kVp. We observed that the proposed method outperforms the original DSC method when metal artifacts were severe. However, we need further extensive studies to verify the proposed method for various CT scan conditions with many more patient images.

4 November 2016 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
MHMOHAMED HEGAZY
MOHAMED HEGAZY
MCMin Hyoung Cho
Min Hyoung Cho
SLSoo Yeol Lee
Soo Yeol Lee
Metal artifacts appearing as streaks and shadows often compromise readability of computed tomography (CT) images. Particularly in a dental CT in which high resolution imaging is crucial for precise preparation of dental implants or orthodontic devices, reduction of metal artifacts is very important. However, metal artifact reduction algorithms developed for a general medical CT may not work well in a dental CT since teeth themselves also have high attenuation coefficients. To reduce metal artifacts in dental CT images, we made prior images by weighted summation of two images: one, a streak-reduced image reconstructed from the metal-region-modified projection data, and the other a metal-free image reconstructed from the original projection data followed by metal region deletion. To make the streak-reduced image, we precisely segmented the metal region based on adaptive local thresholding, and then, we modified the metal region on the projection data using linear interpolation. We made forward projection of the prior image to make the prior projection data. We replaced the pixel values at the metal region in the original projection data with the ones taken from the prior projection data, and then, we finally reconstructed images from the replaced projection data. To validate the proposed method, we made computational simulations and also we made experiments on teeth phantoms using a micro-CT. We compared the results with the ones obtained by the fusion prior-based metal artifact reduction (FP-MAR) method. In the simulation studies using a bilateral prostheses phantom and a dental phantom, the proposed method showed a performance similar to the FP-MAR method in terms of the edge profile and the structural similarity index when an optimal global threshold was chosen for the FP-MAR method. In the imaging studies of teeth phantoms, the proposed method showed a better performance than the FP-MAR method in reducing the streak artifacts without introducing any contrast anomaly. The simulation and experimental imaging studies suggest that the proposed method can be used for reducing metal artifacts in dental CT images.