This work investigates sensor fault diagnostics and fault-tolerant control for a voltage source converter based microgrid (model) using a sliding-mode observer. It aims to provide a diagnosis of multiple faults (i.e., magnitude, phase, and harmonics) occurring simultaneously or individually in current/potential transformers. A modified algorithm based on convex optimization is used to determine the gains of the sliding-mode observer, which utilizes the feasibility optimization or trace minimization of a Ricatti equation-based modification of H-Infinity () constrained linear matrix inequalities. The fault and disturbance estimation method is modified and improved with some corrections in previous works. The stability and finite-time reachability of the observers are also presented for the considered faulty and perturbed microgrid system. A proportional-integral (PI) based control is utilized for the conventional regulations required for frequency and voltage sags occurring in a microgrid. However, the same control block features fault-tolerant control (FTC) functionality. It is attained by incorporating a sliding-mode observer to reconstruct the faults of sensors (transformers), which are fed to the control block after correction. Simulation-based analysis is performed by presenting the results of state/output estimation, state/output estimation errors, fault reconstruction, estimated disturbances, and fault-tolerant control performance. Simulations are performed for sinusoidal, constant, linearly increasing, intermittent, sawtooth, and random sort of often occurring sensor faults. However, this paper includes results for the sinusoidal nature voltage/current sensor (transformer) fault and a linearly increasing type of fault, whereas the remaining results are part of the supplementary data file. The comparison analysis is performed in terms of observer gains being estimated by previously used techniques as compared to the proposed modified approach. It also includes the comparison of the voltage-frequency control implemented with and without the incorporation of the used observer based fault estimation and corrections, in the control block. The faults here are considered for voltage/current sensor transformers, but the approach works for a wide range of sensors.
This paper focuses on robustness and sensitivity analysis for sensor fault diagnosis of a voltage source converter based microgrid model. It uses robust control parameters such as minimum sensitivity parameter , maximum robustness parameter , and compromised both , being incorporated in the sliding mode observer theory using the game theoretic saddle point estimation achieved through convex optimization of constrained LMIs. The approach used works in a way that the mentioned robust control parameters are embedded in Hamilton–Jacobi–Isaacs-Equation (HJIE) and are also used to determine the inequality version of HJIE, which is, in terms of the Lyapunov function, faults/disturbances and augmented state/output estimation error as its variables. The stability analysis is also presented by negative definiteness of the same inequality version of HJIE, and additionally, it also gives linear matrix inequalities (LMIs), which are optimized using iterative convex optimization algorithms to give optimal sliding mode observer gains enhanced with robustness to maximal preset values of disturbances and sensitivity to minimal preset values of faults. The enhanced sliding mode observer is used to estimate states, faults, and disturbances using sliding mode observer theory. The optimality of sliding mode observer gains for sensitivity of the observer to minimal faults and robustness to maximal disturbance is a game theoretic saddle point estimation achieved through convex optimization of LMIs. The paper includes results for state estimation errors, faults’ estimation/reconstruction, fault estimation errors, and fault-tolerant-control performance for current and potential transformer faults. The considered faults and disturbances in current and potential transformers are sinusoidal nature composite of magnitude/phase/harmonics at the same time.
Power generation from river hydropower plants depends mainly on river flow. Water fluctuations in the river make the yield process unpredictable. To reduce these fluctuations, building a small reservoir at the river flow of the hydropower plant is recommended. Conventionally, classic single-pond models are commonly used to design run-of-river hydropower plants. However, such models are associated with fluctuations, sagging, and irregular power fluctuations that lead to irregular water fluctuations. This research proposes a novel idea to replace the single-pond model with a three-pond model to increase the plant’s overall efficiency. The three-pond model is developed as a three-tank nonlinear hydraulic system that contains the same amount of water as a conventional single pond. It also has the advantage of minimizing the run-of-river power plant’s dependence on river flow and increasing efficiency by trapping swell and turbulence in the water. To further increase the efficiency, the developed model was tested for smooth and effective level control using fuzzy control.
Hydropower generation is one of the most prominent renewable sources of power. Run-of-river hydropower is like traditional hydropower but has significantly less environmental impact. Faults in industrial processes are a cause for large amounts of losses in monetary value and off times in industrial processes and consumer utilities. It is more efficient for the system to identify the occurring faults and, if possible, to have the processes running without interruption with the occurrence of a fault. This work uses a model previously proposed—the three-pond hydraulic run-of-river system and integrates it with a turbine and regulated power generation. After integration of the hydraulic system with the turbine and power generation, we then design a diagnostic system for commonly occurring faults within the system. Mathematical models of the faults are formulated and residues are calculated. Fault detection and identification is achieved by analyzing the residues and then a fault-tolerant control is proposed. The Fault Diagnostic Module can correctly detect the faults present and offers sufficient fault compensation to make the system run nearly normally in the event of fault occurrence. With the emergence of distributed power generation smart grids and renewable energy, this fault diagnostic is able to reliably offer uninterrupted power to the grid and thus to consumers.
Experimental techniques to measure fluid flow fields often contain measurement noise and corruption leading to missing velocity vectors that degrade data-driven analysis like POD, DMD etc. that are mostly based on least-squares. Here we use a statistical technique, robust principal component analysis (RPCA) to cope with this problem, RPCA removes the corrupted and misleading flow fields and fill in the missing velocity field vectors to improve the quality of the data by using the information of global coherent structures present in data before applying modal decomposition techniques like POD and DMD. RPCA takes the data matrix and decomposes this matrix into two parts first is a low-rank L matrix which contain coherent structures of flow field data and second is a S matrix which is sparse and contains corrupt entries of flow field. RPCA is applied on the numerical data (DNS) and experimental data of circular cylinder. First, we apply RPCA on the data obtained through direct numerical simulation of flow at Reynolds number 100 and add salt and pepper noise artificially to check the performance of RPCA and error analysis. Next, we investigate its performance on the experimental velocity fields data of vortex induced vibrations. Finally, we apply POD and DMD on the RPCA filtered data which are sensitive to noise and outliers. In all cases RPCA correctly identifies the coherent structures and fill in incorrect or missing information through L1 norm.