Fahad Albalawi

Dr. Fahad Albalawi


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
El-Sayed M. El-KenawyEl-Sayed M. El-Kenawy
El-Sayed M. El-Kenawy
FAFahad Albalawi
Fahad Albalawi
SWSayed A. Ward
Sayed A. Ward
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
MEMarwa M. Eid
Marwa M. Eid
Abdelhameed Fawzy IbrahimAbdelhameed Fawzy Ibrahim
Abdelhameed Fawzy Ibrahim
Detecting transformer faults is critical to avoid the undesirable loss of transformers from service and ensure utility service continuity. Transformer faults diagnosis can be determined based on dissolved gas analysis (DGA). The DGA traditional techniques, such as Duval triangle, Key gas, Rogers’ ratio, Dornenburg, and IEC code 60599, suffer from poor transformer faults diagnosis. Therefore, recent research has been developed to diagnose transformer fault and the diagnostic accuracy using combined traditional methods of DGA with artificial intelligence and optimization methods. This paper used a novel meta-heuristic technique, based on Gravitational Search and Dipper Throated Optimization Algorithms (GSDTO), to enhance the transformer faults’ diagnostic accuracy, which was considered a novelty in this work to reduce the misinterpretation of the transformer faults. The robustness of the constructed GSDTO-based model was addressed by the statistical study using Wilcoxon’s rank-sum and ANOVA tests. The results revealed that the constructed model enhanced the diagnostic accuracy up to 98.26% for all test cases.

12 November 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
Mahmoud ElsisiMahmoud Elsisi
Mahmoud Elsisi
Minh-Quang TranMinh-Quang Tran
Minh-Quang Tran
Hany M. HasanienHany M. Hasanien
Hany M. Hasanien
RTRania A. Turky
Rania A. Turky
FAFahad Albalawi
Fahad Albalawi
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
This paper introduces a robust model predictive controller (MPC) to operate an automatic voltage regulator (AVR). The design strategy tends to handle the uncertainty issue of the AVR parameters. Frequency domain conditions are derived from the Hermite–Biehler theorem to maintain the stability of the perturbed system. The tuning of the MPC parameters is performed based on a new evolutionary algorithm named arithmetic optimization algorithm (AOA), while the expert designers use trial and error methods to achieve this target. The stability constraints are handled during the tuning process. An effective time-domain objective is formulated to guarantee good performance for the AVR by minimizing the voltage maximum overshoot and the response settling time simultaneously. The results of the suggested AOA-based robust MPC are compared with various techniques in the literature. The system response demonstrates the effectiveness and robustness of the proposed strategy with low control effort against the voltage variations and the parameters’ uncertainty compared with other techniques.

25 September 2018 in Mathematics
Verified
Journal Article
Open access
PDF file
ZWZhe Wu
Zhe Wu
FAFahad Albalawi
Fahad Albalawi
JZJunfeng Zhang
Junfeng Zhang
ZZZhihao Zhang
Zhihao Zhang
Helen DurandHelen Durand
Helen Durand
PCPanagiotis Christofides
Panagiotis Christofides
Since industrial control systems are usually integrated with numerous physical devices, the security of control systems plays an important role in safe operation of industrial chemical processes. However, due to the use of a large number of control actuators and measurement sensors and the increasing use of wireless communication, control systems are becoming increasingly vulnerable to cyber-attacks, which may spread rapidly and may cause severe industrial incidents. To mitigate the impact of cyber-attacks in chemical processes, this work integrates a neural network (NN)-based detection method and a Lyapunov-based model predictive controller for a class of nonlinear systems. A chemical process example is used to illustrate the application of the proposed NN-based detection and LMPC methods to handle cyber-attacks.

14 January 2022 in Energy Reports
Verified
Journal Article
Open access
YBYoucef Belkhier
Youcef Belkhier
Rabindra Nath ShawRabindra Nath Shaw
Rabindra Nath Shaw
Miroslav BuresMiroslav Bures
Miroslav Bures
RIRabiul Islam
Rabiul Islam
Mohit BajajMohit Bajaj
Mohit Bajaj
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim

12 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
PSPreeti Ranjan Sahu
Preeti Ranjan Sahu
KSKUMARASWAMY SIMHADRI
KUMARASWAMY SIMHADRI
BMBanaja Mohanty
Banaja Mohanty
PHPrakash Kumar Hota
Prakash Kumar Hota
AAAlmoataz Abdelaziz
Almoataz Abdelaziz
Mahmoud ElsisiMahmoud Elsisi
Mahmoud Elsisi
Nowadays, the operation and control of power systems are a big challenge. An essential part of the power system (PS) control is load frequency control (LFC). Different secondary controllers are implemented for the frequency control problem. Hence, cascaded two-degree freedom and a tilt-integral-derivative controller having a filter (2DOFTIDF) are intended in this paper and implemented for load frequency control. In order to determine the efficiency of the 2DOFTIDF controller, a well-known non-reheat thermal system with/without a governor dead band is considered. A new whale optimization algorithm (WOA) is used to enhance the suggested controller parameters. The predominance of the presented method is exhibited by comparing the consequences with different heuristic techniques tuned to controllers published recently. Further, the simulation results for two test cases indicate that system enactments are enhanced by introducing the suggested controller and are also best suited in the presence of system nonlinearity. Finally, random load fluctuation along with noise and changing the system parameters are also used to determine the reliability of the suggested controller. Compared to the WOA-tuned TIDF controller, the settling time of ΔF1, ΔF2, and ΔPTie is improved by 45.45%, 56.77%, and 20.26%, respectively, with the WOA-tuned 2DOFTIDF controller and by 40%, 48.27%, and 20%, respectively, with the DE-tuned TIDF controller. Experimental validation using the hardware-in-the-loop real-time simulation based on OPAL-RT has been carried out to confirm the viability of the proposed approach.

29 June 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
BBBabes Badreddine
Babes Badreddine
NHNoureddine Hamouda
Noureddine Hamouda
FAFahad Albalawi
Fahad Albalawi
OAOualid Aissa
Oualid Aissa
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
Saad A. Mohamed AbdelwahabSaad A. Mohamed Abdelwahab
Saad A. Mohamed Abdelwahab
This study proposes a way of designing a reliable voltage controller for buck DC/DC converter in which the terminal attractor approach is combined with an enhanced reaching law-based Fast Terminal Synergetic Controller (FTSC). The proposed scheme will overcome the chattering phenomena constraint of existing Sliding Mode Controllers (SMCs) and the issue related to the indefinite time convergence of traditional Synergetic Controllers (SCs). In this approach, the FTSC algorithm will ensure the proper tracking of the voltage while the enhanced reaching law will guarantee finite-time convergence. A Fuzzy Neural Network (FNN) structure is exploited here to approximate the unknown converter nonlinear dynamics due to changes in the input voltage and loads. The Fuzzy Neural Network (FNN) weights are adjusted according to the adaptive law in real-time to respond to changes in system uncertainties, enhancing the increasing the system’s robustness. The applicability of the proposed controller, i.e., the Adaptive Fuzzy-Neural Fast Terminal Synergetic Controller (AFN-FTSC), is evaluated through comprehensive analyses in real-time platforms, along with rigorous comparative studies with an existing FTSC. A dSPACE ds1103 platform is used for the implementation of the proposed scheme. All results confirm fast reference tracking capability with low overshoots and robustness against disturbances while comparing with the FTSC.