Chengyi Liu

Chengyi Liu


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
RZRenyu Zhou
Renyu Zhou
Hu ZhigangHu Zhigang
Hu Zhigang
QZQile Zhao
Qile Zhao
HCHongliang Cai
Hongliang Cai
LXLiu Xuanzuo
Liu Xuanzuo
Liang ChenLiang Chen
Liang Chen
For the same antenna type, numerical differences among the phase center correction (PCC) models released by different institutes can reach several millimeters, which is far beyond the nominal calibration accuracy. This contribution introduces a new method to evaluate the consistency of these PCC models. We first investigated the coupling of phase center offset (PCO) and phase center variation (PCV) through simulation experiments, and the results show that the calibrated PCO values under different strategies may result in large differences, and so do PCV values due to strong coupling with PCO. This is further confirmed by field calibration experiments. Moreover, a new datum parameter is introduced to equivalently transform the PCC models to assess the consistency of PCC models of the same antenna type calibrated under different strategies or by different facilities. It is also essential to perform consistency analysis of PCC models in the coordinate domain. We further investigated these PCC models through a simulated positioning experiment. The results show that millimeter-level consistency of PCC models will lead to the same level of positioning precision in the coordinate domain. Moreover, as a comparison, both baseline positioning and PPP were performed with an antenna-type JAV_RINGANT_G3T NONE based on real observations. Multiday results showed that the average RMS of the positioning differences between PCC models from robot and anechoic chamber calibration is less than 1 mm for the baseline solution and 4 mm for the PPP solution, although the PCC model differences can reach 6 mm in L1 and 4 mm in L2, respectively. Finally, we also investigated the distribution of position biases without PCC or with inaccurate PCC. Considering the actual GPS constellation, we found that position biases have a strong correlation with latitude, if PCV values fluctuate greatly with the users’ elevation angle.

30 October 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
侃徐侃 徐
侃 徐
JTJun Tao
Jun Tao
LTLei Xiao Ting
Lei Xiao Ting
JZJie Zhang
Jie Zhang
CLChengyi Liu
Chengyi Liu
Liang ChenLiang Chen
Liang Chen
GNSS attitude determination has been widely adopted due to its high efficiency, absence of cumulative errors, and ease of installation. However, practical navigation and attitude determination systems often rely on low-cost receivers that struggle with substantial multipath effects, frequent cycle slips, and satellite signal loss, significantly impairing attitude determination accuracy in challenging urban environments. To address this issue, this contribution proposes a constrained dynamic prediction model (C-Dynamics), which enables more accurate initial coordinates and thereby increases the effectiveness of the constrained LAMBDA (CLAMBDA) technique. To evaluate the practical performance of C-Dynamics, two sets of real-world data collected from a vehicle platform were analyzed. The results demonstrate that C-Dynamics significantly enhances the accuracy of initial coordinate estimations across various environments. Compared with the lambda method, the CLAMBDA method + C-Dynamics method (CLAMBDA+CD) improves the fixing rate in the urban environment by 5.6%, and the accuracy of the heading angle, pitch angle, and baseline length improved by 66%, 70.9%, and 84.2%, respectively. Moreover, in challenging high obstruction environments, the fixing rate increased by 43.5%, while the accuracy of heading angle, pitch angle, and baseline length improved by 76.4%, 69.2%, and 94%, respectively. The proposed algorithm effectively addresses the low fixing rate and insufficient accuracy of the LAMBDA method in high obstruction environments and holds practical value for widespread adoption in the mass market.