Hussam Ali

Dr. Hussam Ali

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2010 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
RCRiccardo Cappato
Riccardo Cappato
FFFrancesco Furlanello
Francesco Furlanello
VGValerio Giovinazzo
Valerio Giovinazzo
TITommaso Infusino
Tommaso Infusino
PLPierpaolo Lupo
Pierpaolo Lupo
LALuigi De Ambroggi
Luigi De Ambroggi
Background—: QRS-ST changes in the inferior and lateral ECG leads are frequently observed in athletes. Recent studies have suggested a potential arrhythmogenic significance of these findings in the general population. The aim of our study was to investigate whether QRS-ST changes are markers of cardiac arrest (CA) of unexplained cause or sudden death in athletes. Methods and Results—: In 21 athletes (mean age, 27 years; 5 women) with cardiac arrest or sudden death, the ECG recorded before or immediately after the clinical event was compared with the ECG of 365 healthy athletes eligible for competitive sport activity. We measured the height of the J wave and ST elevation and searched for the presence of QRS slurring in the terminal portion of QRS. QRS slurring in any lead was present in 28.6% of cases and in 7.6% of control athletes ( P =0.006). A J wave and/or QRS slurring without ST elevation in the inferior (II, III, and aVF) and lateral leads (V 4 to V 6 ) were more frequently recorded in cases than in control athletes (28.6% versus 7.9%, P =0.007). Among those with cardiac arrest, arrhythmia recurrences did not differ between the subgroups with and without J wave or QRS slurring during a median 36-month follow-up of sport discontinuation. Conclusions—: J wave and/or QRS slurring was found more frequently among athletes with cardiac arrest/sudden death than in control athletes. Nevertheless, the presence of this ECG pattern appears not to confer a higher risk for recurrent malignant ventricular arrhythmias.

1 February 2016 in Heart Rhythm
Verified
Journal Article
Closed access
ASAntonio Sorgente
Antonio Sorgente
GEGianluca Epicoco
Gianluca Epicoco
Hussam AliHussam Ali
Hussam Ali
SFSara Foresti
Sara Foresti
GAGuido De Ambroggi
Guido De Ambroggi
RCRiccardo Cappato
Riccardo Cappato

1 July 2015 in Heart Rhythm
Verified
Journal Article
Closed access
Hussam AliHussam Ali
Hussam Ali
ASAntonio Sorgente
Antonio Sorgente
PLPierpaolo Lupo
Pierpaolo Lupo
SFSara Foresti
Sara Foresti
GAGuido De Ambroggi
Guido De Ambroggi
RCRiccardo Cappato
Riccardo Cappato

14 August 2008 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Closed access
PDF file
PFP. Francia
P. Francia
MPM. C. Pittalis
M. C. Pittalis
Hussam AliHussam Ali
Hussam Ali
RCR. Cappato
R. Cappato

25 March 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
Hussam AliHussam Ali
Hussam Ali
PLPierpaolo Lupo
Pierpaolo Lupo
SFSara Foresti
Sara Foresti
GAGuido De Ambroggi
Guido De Ambroggi
CLCarmine De Lucia
Carmine De Lucia
RCRiccardo Cappato
Riccardo Cappato
Aims: Air entrapment (AE) has been reported as a potential cause of early inappropriate shocks (ISs) following subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, but a cause–effect relationship is not always evident. This systematic review aims to analyse this phenomenon concerning implantation techniques, electrogram (EGM) features, radiologic findings, and patient management. Methods and results: A systematic search was conducted using PubMed, Embase, and Google Scholar databases following the PRISMA guidelines to obtain all available literature data since 2010 on S-ICD malfunctions possibly due to AE. The final analysis included 54 patients with AE as a potential cause of S-ICD malfunction. Overall, the aggregate incidence of this condition was 1.2%. Of ICD malfunctions possibly due to AE, 93% were ISs, and 95% were recorded within the first week following implantation. Radiologic diagnosis of AE was confirmed in 28% of the entire study cohort and in 68% of patients in whom this diagnostic examination was reported. At the time of device malfunction, EGMs showed artefacts, baseline drift, and QRS voltage reduction in 95, 76, and 67% of episodes, respectively. Management included ICD reprogramming or testing, no action (observation), and invasive implant revision in 57, 33, and 10% of patients, respectively. No recurrences occurred during follow-up, irrespective of management performed. Conclusions: Device malfunction possibly due to AE may occur in ∼1% of S-ICD recipients. Diagnosis is strongly suggested by early occurrence, characteristic EGM features, and radiologic findings. Non-invasive management, principally device reprogramming, appears to be effective in most patients.

1 October 2017 in Heart Rhythm
Verified
Journal Article
Closed access
Hussam AliHussam Ali
Hussam Ali
FFFrancesco Furlanello
Francesco Furlanello
PLPierpaolo Lupo
Pierpaolo Lupo
SFSara Foresti
Sara Foresti
GAGuido De Ambroggi
Guido De Ambroggi
RCRiccardo Cappato
Riccardo Cappato