Javier Lozano-Sanroma

Mr. Javier Lozano-Sanroma

Optometry, Fernández-Vega Ophthalmological Institute, Oviedo, Asturias, Spain
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in The Ocular Surface
Verified
Journal Article
Closed access
ABAlberto Barros
Alberto Barros
JQJuan Queiruga-Piñeiro
Juan Queiruga-Piñeiro
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma
IAIgnacio Alcalde
Ignacio Alcalde
JGJuana Gallar
Juana Gallar
JMJesús Merayo-Lloves
Jesús Merayo-Lloves

1 August 2009 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
LFLuis Fernández-Vega
Luis Fernández-Vega
JAJosé F. Alfonso
José F. Alfonso
BBBegoña Baamonde
Begoña Baamonde
DCDavid Madrid Costa
David Madrid Costa
RMRobert Montés-Micó
Robert Montés-Micó
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma

29 October 2023 in European Journal of Ophthalmology
Verified
Journal Article
Closed access
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
GMGomez Martin Gomez Martin
Gomez Martin Gomez Martin
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma
CLConcepción Renedo Laguna
Concepción Renedo Laguna
Background: Corneal sensitivity can decrease by several ocular conditions, such as dry eye or refractive surgery, which favor ocular epithelial lesions and is measured using an esthesiometer. The study's primary objective was to demonstrate the efficacy and safety of the non-contact esthesiometer BRILL, which delivers air pulses to the corneal surface to assess corneal sensitivity. Methods: A single-center, prospective, controlled pilot study was carried out in adult patients with healthy eyes and or with pathology. Corneal sensitivity measurements were made in triplicate for both eyes at three consecutive visits. The esthesiometer BRILL was used in all visits, and on the last visit, the contact esthesiometer Cochet-Bonnet was also used. The results of both devices were compared by transforming them into force values. Results: 54 subjects with a mean age of 50.43 (SD 16.55, interval 18–87), 77.78% women, were included. Comparing the forces applied by both esthesiometers in the healthy eyes, in the eyes with pathology in all the groups, and in the dry eyes showed significant differences, p = 0.03603, p = 0.00614, and p = 0.0001, respectively. Conclusion: The BRILL esthesiometer proved to be an effective and safe tool for non-contact assessment of corneal sensitivity with operator-independent repeatability. The measurements had a good agreement and comparable range with the Cochet-Bonet aesthesiometer measurements in healthy and dry eyes but with no interchangeable values. This portable device can help ophthalmologists and optometrists to diagnose eye pathologies that cause decreased corneal sensitivity and to assess the efficacy of therapy and disease progression.

25 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ABAlberto Barros
Alberto Barros
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma
JQJuan Queiruga-Piñeiro
Juan Queiruga-Piñeiro
LFLuis Fernández-Vega-Cueto
Luis Fernández-Vega-Cueto
EAEduardo Anitua
Eduardo Anitua
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
Purpose: To analyze the changes in corneal innervation by means of in vivo corneal confocal microscopy (IVCM) in patients diagnosed with Evaporative (EDE) and Aqueous Deficient Dry Eye (ADDE) and treated with a standard treatment for Dry Eye Disease (DED) in combination with Plasma Rich in Growth Factors (PRGF). Methods: Eighty-three patients diagnosed with DED were enrolled in this study and included in the EDE or ADDE subtype. The primary variables analyzed were the length, density and number of nerve branches, and the secondary variables were those related to the quantity and stability of the tear film and the subjective response of the patients measured with psychometric questionnaires. Results: The combined treatment therapy with PRGF outperforms the standard treatment therapy in terms of subbasal nerve plexus regeneration, significantly increasing length, number of branches and nerve density, as well as significantly improving the stability of the tear film (p < 0.05 for all of them), and the most significant changes were located in the ADDE subtype. Conclusions: the corneal reinnervation process responds in a different way depending on the treatment prescribed and the subtype of dry eye disease. In vivo confocal microscopy is presented as a powerful technique in the diagnosis and management of neurosensory abnormalities in DED.

11 May 2023 in Medicina
Verified
Journal Article
Open access
PDF file
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma
ABAlberto Barros
Alberto Barros
IAIgnacio Alcalde
Ignacio Alcalde
RSRonald Sánchez-Ávila
Ronald Sánchez-Ávila
JQJuan Queiruga-Piñeiro
Juan Queiruga-Piñeiro
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
Background and Objectives: Dry eye disease (DED) is a common and very symptomatic pathology that affects normal daily activity. The aim of the study was to evaluate the efficacy of plasma rich in growth factors (PRGF) added to one routine treatment protocol for DED (artificial tears substitutes, lid hygiene, and anti-inflammatory therapy). Materials and Methods: Patients were divided into two groups of treatment: standard treatment group (n = 43 eyes) and PRGF group (n = 59). Patients’ symptomatology (inferred from OSDI and SANDE questionnaires), ocular inflammation, tear stability, and ocular surface damage were analyzed at baseline and after 3 months of treatment. Results: OSDI test scores were significantly lower in both groups (p < 0.001). SANDE frequency test scores also improved statistically, with differences between groups (p = 0.0089 SANDE frequency and p < 0.0119 SANDE severity). There was a greater reduction in ocular redness (ocular inflammation) in the PRGF group (p < 0.0001) and fluorescein tear break-up time was significantly improved in the PRGF group (p = 0.0006). No significant changes were found in terms of ocular surface damage. No adverse events were obtained in either group. Conclusions: The addition of PRGF to the standard treatment of DED, according to the results obtained, proved to be safe and produced an improvement in ocular symptomatology and signs of inflammation, particularly in moderate and severe cases, when compared to standard treatment.

Verified
Journal Article
Open access
PDF file
JQJuan Queiruga-Piñeiro
Juan Queiruga-Piñeiro
ABAlberto Barros
Alberto Barros
JLJavier Lozano-Sanroma
Javier Lozano-Sanroma
ACAndrés Fernández-Vega Cueto
Andrés Fernández-Vega Cueto
IRIgnacio Rodriguez-Una
Ignacio Rodriguez-Una
JMJesús Merayo-Lloves
Jesús Merayo-Lloves
Background: The mechanism that could increase intraocular pressure (IOP) during scleral lens (SL) wear is not fully understood, although it may be related to compression of the landing zone on structures involved in aqueous humor drainage. Methods: Thirty healthy subjects were fitted with two SLs of different sizes (L1 = 15.8 mm, L2 = 16.8 mm) for 2 h in the right eye and left eye as a control. Central corneal thickness (CCT), parameters of iridocorneal angle (ICA), Schlemm’s canal (SC), and optic nerve head were measured before and after wearing both SLs. IOP was measured with a Perkins applanation tonometer before and after lens removal and with a transpalpebral tonometer before, during (0 h, 1 h, and 2 h), and after lens wear. Results: CCT increased after wearing L1 (8.10 ± 4.21 µm; p < 0.01) and L2 (9.17 ± 4.41 µm; p < 0.01). After L1 removal, the ICA parameters decreased significantly (p < 0.05). With L2 removal, nasal and temporal SC area and length were reduced (p < 0.05). An increased IOP with transpalpebral tonometry was observed at 2 h of wearing L1 (2.55 ± 2.04 mmHg; p < 0.01) and L2 (2.53 ± 2.22 mmHg; p < 0.01), as well as an increased IOP with Perkins applanation tonometry after wearing L1 (0.43 ± 1.07 mmHg; p = 0.02). Conclusions: In the short term, SL resulted in a slight increase in IOP in addition to small changes in ICA and SC parameters, although it did not seem to be clinically relevant in healthy subjects.