Micromanipulation for applications in areas such as tissue engineering can require mesoscale structures to be assembled with microscale resolution. One method for achieving such manipulation is the parallel actuation of many microrobots in parallel. However, current microrobot systems lack the independent actuation of many entities in parallel. Here, the independent actuation of fifty opto-thermocapillary flow-addressed bubble (OFB) microrobots in parallel is demonstrated. Individual microrobots and groups of microrobots were moved along linear, circular, and arbitrary 2D trajectories. The independent addressing of many microrobots enables higher-throughput microassembly of micro-objects, and cooperative manipulation using multiple microrobots. Demonstrations of manipulation with multiple OFB microrobots include the transportation of microstructures using a pair or team of microrobots, and the cooperative manipulation of multiple micro-objects. The results presented here represent an order of magnitude increase in the number of independently actuated microrobots in parallel as compared to other magnetically or electrostatically actuated microrobots, and a factor of two increase as compared to previous demonstrations of OFB microrobots.
Gallium alloys are liquids at room temperature, and are suitable as conductors in electronic circuits. Furthermore, gallium-based liquid metals immersed in a water-based electrolyte such as sodium hydroxide (NaOH) can be electrically actuated, enabling reconfigurable electronics such as RF switches, tunable filters, and tunable antennas. However, NaOH in liquid-metal reconfigurable electronics also causes RF losses that should be minimized by careful design and simulation. To accurately simulate the effects of NaOH at microwave frequencies, the complex permittivity of NaOH is required over the operating frequency range. Here, the complex dielectric permittivity of aqueous NaOH solutions is determined from 0.2 to 20 GHz by dielectric spectroscopy. NaOH solutions with concentrations of 0.01 moles/liter (M), 0.1 M, 0.25 M, 0.5 M, 0.75 M, 1.0 M, 1.25 M, and 1.5 M are investigated at 20 °C. The complex permittivity spectra are fitted by a Cole-Cole relaxation time distribution. In addition, the fitting parameters, including static permit-tivity.... and relaxation time τ are reported, along with the distribution parameter α. The measured permit-tivity of NaOH is used to simulate two liquid-metal RF components using NaOH. The measured RF perfor-mance are in good agreement with the simulated results that include the effects of NaOH.
12 January 2021 in IEEE Open Journal of Nanotechnology
Microrobots are promising tools for applications that require micromanipulation, such as single-cell manipulation and surgery, tissue engineering, and desktop manufacturing. This paper briefly reviews common microrobot actuation mechanisms, then reviews current progress in several capabilities that are desirable for micromanipulation, with an emphasis on optothermal microrobots.
5 December 2019 in IEEE Transactions on Microwave Theory and Techniques
Liquid metals such as gallium alloys have a unique potential to enable fully reconfigurable RF electronics. One of the major drawbacks for liquid-metal electronics is their interaction with solid-metal contacts, which results in unwanted changes to the electrical performance and delamination of solid-metal contacts due to atomic diffusion of gallium at the liquid-solid interface. In this article, we present a solution to this problem, namely, Laplace barriers, which demonstrate reversible liquid-metal-to-liquid-metal RF connections that provide pressure-directed control of the fluids. While the effect of these channel designs provide superior control over the fluid's position, their effect on RF transmission has not been explored, and the inherent trade space between the microfluidic design and RF performance has never been detailed. RF tunability is demonstrated by fabricating, testing, and modeling a reconfigurable RF microstrip transmission line with integrated the Laplace barriers which operates between 0.5 and 5 GHz. The effect of the Laplace barrier length on both fluidic control and RF performance is reported and compared with the extreme example of a tapered line, which is analogous to a single elongated gap between two Laplace barriers. This approach opens the potential for future all-liquid reconfigurable RF electronic circuits where physical connections between solid and liquid metals are minimized or possibly eliminated.
Four types of liquid‐metal‐based tunable capacitors with a high tuning range are demonstrated. The capacitors are easily fabricated by placing a pair of liquid‐metal‐filled tubes in contact with one another. Tunability is achieved by varying the length of the liquid metal in one of the tubes using a mechanical pump. Four different structures are demonstrated: parallel‐tube, folded‐tube, coil, and spiral capacitors. The highest measured tuning ratio is 42:1, and the highest change in capacitance per unit length of the pumped liquid metal is 0.07 pF/mm.
Accurate control and precise positioning of opto-thermocapillary flow-addressed bubble microrobots are necessary for micromanipulation. In addition, micromanipulation using the simultaneous actuation of multiple microrobots requires a robust control system to enable independent motion. This paper demonstrates a hybrid closed-loop vision-assisted control system capable of actuating multiple microrobots simultaneously and positioning them at precise locations relative to micro-objects under manipulation. A vision-assisted grasp-planning application was developed and used to calculate the necessary trajectories of the microrobots to form cages around micro-objects. The location of the microrobots and the micro-objects was detected at the caging locations using a particle-tracking application that used image feedback for precise positioning. The closed-loop image feedback information enabled the position update of the microrobots, allowing them to precisely follow the trajectory and caging locations calculated by the grasp-planning application. Four microrobots were assigned to cage a star-shaped micro-object using the closed-loop control system. Once caged, the micro-object was transported to a location within the workspace and uncaged, demonstrating the micromanipulation task. This microrobotic system is well suited for the micromanipulation of single cells.